OCMA-300 Oil Content Analyzer

Overview

The OCMA-300 is an automated portable unit for monitoring oil content in both fresh water and saltwater. The one-touch monitoring process is fully automated, from sample extraction to analysis and sample expulsion. The OCMA-300 utilizes an S-316 extraction solvent to ensure superior oil particle stability and infrared absorptiometry for sample analysis. Using 0mg/l -200mg/l dynamic ranging, the unit is capable of analyzing both high and low concentrations. The OCMA-300 provides swift, highly accurate analysis of the oil content of both fresh water and saltwater as well as that of such fluids as those found at factories and wastewater treatment plants.

Features

  • A microcomputer provides automated analysis of the samples at the touch of a button.
  • Dynamic ranging provides analysis from 0mg/l-200mg/l without manual switching.
  • The use of an S-316 extraction solvent ensures the highest levels of oil particle stability.
  • A digital display eliminates the misreading of analysis results. A visual display alerts users to the unit's operating status.
  • The use of a proprietary syringe ensures a fixed amount of sample water and solvent.

Manufactured by HORIBA

Specifications

Measurement principle:

Solvent extraction, NDIR
analysis (Infrared spectroscopy)

Measurement range:

0mg/l ~ 200mg/l dynamic ranging

Resolution

0 to 99.9 mg/L; 0.1 mg/L
100 to 200 mg/L; 1 mg/L

Repeatability

0 to 9.9 mg/L; ± 0.2 mg/L ± 1 digit
10.0 to 99.9 mg/L; ± 2 mg/L ± 1 digit
100 to 200 mg/L; ± 4 mg/L ± 1 digit

Measurement

Automatic after
introduction of the oily water sample or
manual operation, selectable

Calibration

Automatic zero and span
calibration after the oily water sample is
introduced to the instrument.

Extraction Solvent

S-316 solvent

Sample/Solvent Volume

20 mL/10 mL

Extraction Method

Built-in extractor for oily water samples

Display

Measured value; 3 digits LCD with backlight
Message; Character display LCD with back-light (16×2 characters)

Functions

Data memory up to 50 data, Self diagnostics, Stable type display, Interactive operation, Calendar clock

Output

Digital display, RS-232C and parallel printer port

Ambient Temperature

0 to 40 ℃

Power

100 to 240 V AC ±10%, 50/60 Hz
100 to 120 V AC; approx. 80 VA
200 to 240 V AC; approx. 120 VA

Dimensions

200(W)×315(D)×342(H) mm
7.8(W)×12.4(D)×13.5(H) in

Mass

Approx. 7 kg/15.5 lb