ASGU-370TS

Automatic Span Gas Unit Transferstandard

The portable calibration unit ASGU-370TS is designed for the dynamic and continual manufacture of zero and span gas to perform all ongoing quality control procedures according EN Norms. To prepare various span gas concentrations the unit uses technologies like dilution, permeation, Gas Phase Titration.

 

事业部: 过程与环境
产品分类: 空气质量
制造商: HORIBA (Austria) GmbH
Base product: ASGU-370 series
  • Portable one component multipoint calibration system acc. EN 14211 or EN 14212 or EN 14626
  • High accuracy of span gas in cause of usage of factory calibrated digital thermal mass flow controllers in high quality
  • Comfortable operation via big illuminated Touch-Screen-Display
  • Operation via RS232 and Ethernet interface (Bayern Hessen protocol)
  • Delivery scope includes remote software for easy external handling (Ethernet)
  • High flexibility by free definable span points (up to 20)
  • High flexibility by free definable cycles (e.g. Lack of fit)
  • High flexibility by free definable sequences (stringing cycles together)
  • Programmable timer allows time shifted start of calibration process
  • Internal data logger (option) stores raw values from calibration procedure (set value and actual value, status) for reporting with evaluation software (included in scope of delivery)

 

 

Principle

Dilution (incl. built in cylinder), Permeation,  Gas Phase Titration, (Mixed gas dilution)

Application

Quality control in Laboratory
Quality control in field

Stage of extension

Only one channel (module) per unit

Flow regulation

Digital Mass flow Controllers

Span gas repeatability

+/- 1%

Span gas linearity

+/- 2% (minimum flow >20% F.S.)

Permeation system
(NO2, SO2, NH3, H2S, BTX)

PID temperature controller with Pt 100 sensor
Temperature: 50°C
Accuracy ±0,1°C
Indication of actual temperature on display

Zero Air Supply

Internal Zero gas preparation

Operation

Manual (Touch Screen Display)
External via RS232 (Gesytec Protocol)
External via Ethernet (Remote Software)

Battery packFor uninterruptible power supply for approx. 30min purge mode without mains voltage

Power 

230VAC, 50Hz
Power consumption depends on stage of channel

Dimensions

510mm(W) x 310mm(D) x 430mm(H)

Mass

Depends on stage of extension

空气质量监测
在经济高速增长时期,日本饱受水污染、空气污染等各种污染的困扰。回到蓝天白云和青山绿水的第一步是分析。HORIBA 的测量仪器在各个领域发挥着积极作用。通过使用HORIBA的分析仪器,能够确定空气和水的质量是否得到净化以及符合既定环境法规。美丽的环境是世界的财富。今后,HORIBA将继续通过提供测量分析设备为保护全球环境作出贡献。

留言咨询

如您有任何疑问,请在此留下详细需求信息,我们将竭诚为您服务。

* 这些字段为必填项。

更多推荐

AFCU-360M
AFCU-360M

Function Control Unit with Mass Flow Controllers

AFCU-360RC
AFCU-360RC

Function Control Unit by Remote Control

AP-370 系列
AP-370 系列

空气污染监测仪

APCA-370
APCA-370

大气污染监测用二氧化碳监测仪

APDA-371
APDA-371

空气颗粒物监测仪

AQMS
AQMS

空气质量监测系统

ASGU-370 series
ASGU-370 series

Automatic Span Gasgenerator Unit

ASGU-370P
ASGU-370P

Automatic Span Gas Unit for Parallel calibration

ASGU-370S
ASGU-370S

Automatic Span Gas Unit for Serial calibration

ASGU-370TS SPLIT
ASGU-370TS SPLIT

Automatic Span Gas Generator Unit for Quality control at field test

ASS-370
ASS-370

Sampling System

PX-375
PX-375

带 X 射线荧光的连续颗粒物监测仪

ZGG-370
ZGG-370

Zero Gas Generator

AFCU-360M
AFCU-360M

Function Control Unit with Mass Flow Controllers

ASGU-370P
ASGU-370P

Automatic Span Gas Unit for Parallel calibration

ASGU-370S
ASGU-370S

Automatic Span Gas Unit for Serial calibration

ASGU-370TS SPLIT
ASGU-370TS SPLIT

Automatic Span Gas Generator Unit for Quality control at field test

D700MG
D700MG

高响应压力非敏感质量流量器

D700T
D700T

Best Performance Pressure Insensitive Mass Flow Module

D700uF
D700uF

Micro Flow Pressure Insensitive Mass Flow Module

D700WR
D700WR

宽范围压敏质量流量计

FS-3000
FS-3000

热式气体分流器

LF-F/LV-F 系列
LF-F/LV-F 系列

数字式液体质量流量计/控制器

SEC-8000 F/D/E 系列
SEC-8000 F/D/E 系列

高温数字式质量流量控制器

SEC-E 系列
SEC-E 系列

质量流量控制器

SEC-N100 系列
SEC-N100 系列

数字式质量流量控制器

SEC-Z500X
SEC-Z500X

多量程/多气体数字质量流量控制器

SEC-Z700S 系列
SEC-Z700S 系列

新型压力补偿质量流量控制器

SEC-Z700X 系列
SEC-Z700X 系列

压力补偿质量流量控制器

Corporate