HORIBA's SLFA-UV21A is the latest sulfur analyzer instrument that reflects the demanding needs to measure ultra-low sulfur fuels, diesel and RFG.

HORIBA's SLFA-UV21A sulfur in oil analysis system is the latest sulfur analyzer instrument that reflects the demanding needs to measure ultra-low sulfur fuels, diesel and RFG. The combination of HORIBA's years of experience in sulfur analysis and the proven technology of our atmospheric sulfur detector creates a revolutionary analyzing technology that involves high sensitivity and precision. SLFA-UV21A confirms to the standard "ASTM D5453(USA)"

The use of combustion ultraviolet fluorescence provides a lower detection limit of 30 ppb and a measurement range of 30 ppb to 1 wt%.

A detection limit of 30 ppb sulfur takes you to new realms of measurement sensitivity. HORIBA's high sensitivity analyzer makes quick, accurate measurements of petroleum fuel samples from gasoline to light oils. Windows-based application software allows easy operation and sophisticated functions.

Low level nitrogen analysis is now possible utilizing HORIBA's recognized chemiluminescence nitrogen detector technology. This is in addition to the hightly accurate and reliable low-level sulfur analysis by the UV fluorescence method.

Merkmale

  • Reflective filter for high sensitivity analysis
  • Horizontal oven offers higher combustion efficiency
  • Excellent repeatability and 30ppb detection limit
  • Unique 4 axes auto sampler with automatic syringe cleaning mechanism
  • Windows-based application software allows easy operation and sophisticated functions.
  • SLFA-UV21A confirms to the standard "ASTM D5453 (USA)"

Hergestellt von HORIBA

Spezifikationen

Model

SLFA-UV21A

Principle

Combustion ultraviolet fluorescence method

Sample

Gasoline, Kerosene, Light oil etc
(Viscosity under 20mm2/S)

Element

Sulfur

Range

0-1%

Detection Limit

30 ppb (Toluene measurement 3sigma)

Accuracy

SD0.5 ppm (at 30 ppm)
SD0.2 ppm (at 15 ppm)

Sample requirement

5-20µL (standard: 10µL)

Measurement time

Approx 1 to 5min from the start of sample injection

Functions

Cleaning: Cleaning and combustion tube washing
Interrupt: Editable sequence of measurement
Self-diagnosis: Alarm display, maintenance counter
Memory: Measured values automatically saved
Graph data: Extraction curves automatically saved
Statistic: Average, SD, CV, graphics
Option: Automatic input of density from the optional density meter

Auto sampler

Type: X,Y,Z,R drive(horizontal oven)with
syringe cleaning function
Sample: Up to 42 samples

Gass supply

Oxygen 99,5% or higher
Argon 99,99%

Power

AC 100/120, 200/220/240V, 50/60Hz
Approx 1,5kVA
(When powered at AC100V, an AC100/120V
step-up transformer is used.)

Mass

70kg (Combustion unit 40kg, Detector unit 30kg)

Option

Density meter

Diagramme

SLFA-UV21A Dimensional outline (mm)

Ähnliche Produkte

SLFA-2100/2800

Die SLFA-2100/2800 Geräte sind für höchste Ansprüche in Bezug auf Detektionslimit, Messbereich und...

SLFA-20

Das SLFA-20 wurde speziell für die neuen Anforderungen bei der Bestimmung von Schwefel in Öl mit...

EMIA-V series

Die HORIBA EMIA-V Serie ist besonders geeignet zur Bestimmung von Kohlenstoff und Schwefel in...

EMIA-8100 series

Die EMIA-8100 Serie ist mit einem elektrischen Widerstandsofen ausgestattet und misst Kohlenstoff...

XGT-1000WR/1100WR

Das XGT-1000WR wurde speziell für WEEE/RoHS/ELV Anwendungen mit hoher Sensitivität bei der...

XGT-1700WR

Neuestes Modell der XGT-1000WR Serie mit höherer Performance und Sensitivität durch ein...

XGT-5000WR

Hochsensitives Röntgenfluoreszenzgerät für qualitative und quantitative Analyse inklusive eines...

XGT-5700WR

Neuestes Modell der XGT-5000WR Serie mit höherer Performance und Sensitivität durch ein...

XGT-7000

Einzelpunktanalyse und automatisiertes hyperspektrales Imaging

zwei verschiedene...

XGT-5000

Einzelpunktanalyse und automatisiertes Imaging

Probe unter Normaldruck

Analysenspot-Durchmesser...