IT-550 Series IR Non-Contact Thermometers

Vue d'ensemble

The HORIBA IT-550 Series non-contact thermometers are equipped with a twin-beam marker that enables you to target the location that you want to measure quickly and accurately, and to confirm the measurement point at a glance. Choose from one of three models for an ideal match to your temperature measurement application! IT-550F is designed for field use, the IT-550L is for laboratory use, and the IT-550S is for making spot measurements.

Fonctions

Realization of a Ø 24/1000 mm (IT-550F/L)The IT-550F and IT-550L have a measurement field that is about 1/3 the size of previous models, allowing accurate temperature measurement of areas from a distance. The IT-550Shas a measurement spot size of Ø 2.5mm and a range of 70mm.

Realization of a splash-resistant, non-contact thermometer. The IT-550 Series thermometers are splash-resistant, so they can be safely used with wet hands, and in wet environments and rain. This instrument is ideally suited for monitoring the temperature of food items.

IECIP54 (splash resistant): no adverse effects resulting from exposure to splashed water from any direction.

The IT-550 Series thermometers are equipped with a data hold function, and have both digital and analog outputs for connection to computers and printers for flexible data manipulation and output.

Data printout is possible by connecting the expansion kit to the IT-550F model (which is equipped with data hold), and the IT-550L and IT-550S units have an analog output that can be used to record data on a data logger or to process data using a personal computer.Expansion kit sold separately.


Fabriqué par HORIBA

Caractéristiques

Spectral response:

8 to16 µm

Measurement temp.range:

-50 to 500 °C

Display range (resolution):

IT-550F -55.0 to 505.0°C(0.1°C)
IT-550L/S -55.0 to 505.0°C(1°C) or -55.0 to 505.0°C (0.1°C)

Display range (resolution):

-55.0 to 505.0°C(0.1°C)(IT-550F)
IT-550L/S -55 to 505°C(1°C) or -55.0 to 505.0°C(0.1°C)

Accuracy:

IT-550F -50.0 to -0.1°C:within ±(10% of read value -2)°C 0.0 to °C: within ±2°C200.0 to 500.0°C: within ±(1% of read value)°C Conditions: case temperature 18 to 28°C, relative humidity 55%, ε=1.00

IT-550L/S -50.0 to -0.1°C(or -50 to -1°C): within ±(10% of read value -2)°C 0.0 to 200°C(or 0 to 200°C):within ±2 °C(or±2.0°C) 200.0 to 500.0°C (or 200 to 500°C): within ±(1% of read value)°C Conditions: case temperature 18 to 28 °C, relative humidity 55%, ε=1.00

Repeatability:

IT-550F Within ±1°C(0-50.0 to -0.1°C) Within ±0.5°C(0.0 to 500°C)
IT-550L/S 0.1°C display resolution: Within ±1°C(-50.0 to -0.1°C) Within ±0.5°C (0.0 to 500°C)1°C display resolution: Within ±2°C(-50 to -1°C)

Response time:

IT-550F 1.6 sec. max. (95%)
IT-550L/S 0.7 sec. max. (95%) 1°C display resolution: 1.6 sec. max. (95%) 0.1°C display resolution:

Target size:

IT-550F φ24 ±3 mm/1000 mm,90% energy limit)
IT-550L/S φ2.5 mm/73 mm(planned)

Emissivity setting:

0.10 to 1.00 in 0.01 steps

Sighting:

Two-point laser marker

Water resistance:

IP54 (IEC529)

Operating time, humidity:

0 to 40°C, relative humidity 35 to 85%, and no condensation

Power:

One 9 V dry battery (6F22 or 6LR61), or special- purpose AC adapterPower

Battery life:

20 continuous hours using laser marker (alkaline battery)

Dimensions/Weight:

200(L) x 47(W) x 48(H)mm 280g(battery included)

Functions:

IT-550F Data memory (130 points), printer output, RS-232C, auto off, screw hole for camera tripod.
IT-550L/S Analog output (0 to 1V scaling function), RS-232C, Max./Min. value display, auto off, screw hole for camera tripod.

Temperature:

-20 to 55°C no condensation storage

Standard accessories:

Instruction manual, Carry case, hand strap, battery, opener for the battery lid.

Note: Use of analog output, printer output, RS- 232C, and the AC adapter requires the expansion kit option (sold separately).