HE-480R

Panel-mount type resistivity meter (resistivity meter)

UPW (ultra-pure water) monitoring for the semiconductor, electronics, food, and pharmaceutical industries.

A resistivity meter with high-precision temperature compensation performance. Ideal for continuous monitoring of ultra-pure water used in various fields such as semiconductor, electronics, food, and pharmaceutical manufacturing.

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Highly responsive temperature sensor

Helps to minimize fluctuations in measurement values due to delayed temperature compensation in the event of sudden changes in water temperature.

Product nameindustrial resistance meter
ModelHE-480R
Measurement
method
Electrode type (2-electrode method)
Cell constant0.01/cm
Temperature
sensor
specifications
Platinum resistance 1000 Ω/0℃
Measuring rangeMeasurement unitkΩ•m0 to 2.000 to 20.00 to 200.00 to 1000 *
MΩ•cm0 to 0.2000 to 2.000 to 20.000 to 100.0 *
*: Measurable without temperature compensation
Temperature: 0℃ to 100℃ (Select your desired decimal point from 0, 1, and 2 digits.)
RepeatabilityWithin ±0.5% of the full scale (in equivalent input)
LinearityWithin ±0.5% of the full scale (in equivalent input)
Transmission
output
4 mA to 20 mA DC: input/output isolated type
Maximum load resistance: 900Ω
Transmission output range: Freely selectable within the measurement range
Contact outputOutputs: 2 points
Alarm contact output (R1 and R2)
 Contact type: relay contact, SPDT (1c)
 Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
 Contact function: selectable from upper/lower limit operation (ON/OFF control), alarm, and maintenance.
Calibration functionSpecific resistance: Based on the specified compensation coefficient for cell constant (parameter input)
Temperature: Calibrated by comparing with the reference thermometer
Transmission
output hold feature
  • Previous value hold
  • Optional value hold
  • Continuous
    Selectable from the above (However, only the previous value hold is available in the maintenance mode.)
Self-diagnosis
function
  • Sensor diagnosis
    Short-circuit and disconnection of the temperature sensor
  • Out of the measurement range
  • A/D converter scale over
  • Converter error
Temperature
compensation
  • Based on the temperature characteristics of extra deionized water (reference temperature: 25℃)
  • Based on the reference temperature and user-defined temperature coefficient (reference temperature: 5℃ to 95℃)
  • No temperature compensation
Temperature
compensated
range
0℃ to 100℃
Extra deionized
water specific
resistance selection
Measurement
unit
kΩ•m182.3 (standard), 181.8, 182.4Select from options shown on the left.
MΩ•cm18.23 (standard), 18.18, 18.24
Clipping functionWhen the measured value is above the upper limit of the measurement range derived from the specified specific resistance, the specified resistance is used as the measured value.
Ambient
temperature
−5℃ to 45℃
Relative humidity20% to 85% (without dew condensation)
Storage
temperature
−25℃ to 65℃
Power supplyRated voltage 100 V to 240 V AC, 50/60 Hz, 10 VA (max.)
StructureIndoor-use panel installation type
Panel case: ABS, Terminal: PBT
Panel: IP65 dust and water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920)
Rear case: IP20, Terminal:IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Conforming
standards
CE MarkingEMC Directive: EN61326-1
Low Voltage Directive: EN61010-1
RoHS Directive: EN50581
FCC RuleFCC Part15
External
dimensions
48(W) mm × 96 (H) mm × 115 (D) mm
Case depth: approx. 105 mm (when panel-mounted)
MassApprox. 400 g
Compatible sensorsERD/ERF-series specific resistance sensor, cell constant 1.0/m (0.01/cm)

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

HC-200F
HC-200F

Field-installation Type Fluoride Ion Concentration Meter

HC-200NH
HC-200NH

Field-installation type ammonia nitrogen meter

HC-300F
HC-300F

Field-installation Type Fluoride Ion Concentration Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-200FL
HD-200FL

Field-installation type optical dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

HO-200
HO-200

Field-installation type ORP meter

HO-300
HO-300

Field-installation type ORP meter

HP-200
HP-200

Field-installation type pH meter

HP-300
HP-300

Field-installation type pH meter

HP-480
HP-480

Panel-mount type pH meter

HP-480PL
HP-480PL

Panel-mount type pulse proportion control pH meter

HP-480TP
HP-480TP

Panel-mount type pH meter with industrial time sharing proportional control

HP-960FTP
HP-960FTP

Panel-mount type pH meter with 4-point alarm time sharing proportional control

HR-480
HR-480

Panel-mount type galvanic residual chlorine meter

IT-470F-H
IT-470F-H

High-Accuracy Infrared Thermometer [Built-in type]

IT-480 series
IT-480 series

High-Accuracy Infrared Thermometers [Stationary type]

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

HO-200
HO-200

Field-installation type ORP meter

HO-300
HO-300

Field-installation type ORP meter

HR-480
HR-480

Panel-mount type galvanic residual chlorine meter

HT-110
HT-110

On-line TOC analyzer

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

TOCADERO ONE
TOCADERO ONE

Automatic Total Organic Carbon Analyzer (On-line TOC analyzer)

TW-150
TW-150

Water distribution monitor

U-50
U-50

Multi-parameter water quality checker