ENDA-5000 series

Stack Gas Analysis System

Continuous simultaneous and high-precision measurement of NOx, SO2, CO, CO2, O2, CH4 and N2O 

HORIBA has over 100,000 CEM systems installed and 30 years of quality and experience. That is the base on which HORIBA's ENDA-5000 series of stack-gas analysis systems are built. These systems have a small footprint and use cross modulated non-dispersive infrared (NDIR) and magneto-pneumatic detectors that are inherently drift-free. The ENDA-5000 series are superior continuous analysis systems that perform reliably for difficult exhaust gas measurements, when measurement errors cannot be tolerated. This CEM series features a intuitive touch panel that makes every operation available with the touch of a single button. The ENDA-5000 series systems are also designed for ease of maintenance. They are ideal for a variety of uses, including emissions monitoring from steam boilers, refuse incinerators, and electric power generation plants to assure pollution standards are being met.

 

Division: Combustion
Manufacturing Company: HORIBA, Ltd.
  • Long-term stability : Cross-flow modulated non-dispersive infrared (NDIR) detection is renowned for long-term stability
     
    1. No need for optical adjustments
      With  NDIR, the sample gas and reference gas are intromitted into a single measurement cell alternately to obtain modulation signal. Therefore there is no need to adjust two different optical paths so that they are balanced.
    2. A stable zero point
      Since ENDA-5000 series output the difference between the measured gas and the reference gas each time measurement occures (once a second), the zero point is extremely stable.
    3. Continuous cleaning keeps the cell clean
      Since cleaning air is fed into the sample cell in between each batch of sample gas, the cell resistes contamination and normally remains clean.This reduces span drift and makes the equipment safe and stable for long periods of time.
       
  • Compact : Body yields wider maintenance area
    The ENDA-5000 series can be installed almost anywhere, with ample room on all sides for easy access and much easier maintenance.
     
  • Easy to use : Features an intuitive touch panel
    The operator can easily switch between the corrected and converted density settings screens or view alert information with touch of a single button.
     
  • Complies to world environmental regulations by local engineering

* Please consult HORIBA for further details.


<Other Features>

  • Continuous simultaneous measurement of up to 5 components with one system
    HORIBA's innovative optical technology enables ENDA-5000 series measure up to five components which can be arranged any combination.
     
  • Correction for interference
    The interference correcting sensor uses a unique interference filter to compensate for the influence of interference by other gases.
     
  • Better alerts and extra alerts
    In addition to the alert functions available in the past, the ENDA-5000 series feature extra alert functions. A continuous checking process can prevent the unit from stopping due to a failure, reducing the risk of failed measurements and assuring consistent operation.
     
  • Dramatically reduced correction time for SO2
    Corrections of SO2 measurements using wet base methods of the past took a great deal of time (about 15 minutes), but with the ENDA-5000 series' dry base method, correction takes only three minutes. 

 

CH4 and N2O measurement are also available. Please contact us for more information.

 
Related Industries

▶ Thermal Power Generation

▶ Waste to Energy Power Generation

▶ Biomass Power Generation

▶ Iron and Steel Production

▶ Oil Refinery

▶ Petrochemical Industry

Related Applications

▶ Monitoring of SO₂ for Flue Gas Desulfurization

Model

ENDA-5000

Component*1

NOx

SO2

CO

CO2

O2*2

Measurement methods

NDIR

NDIR

NDIR

NDIR

Magneto-pneumatic detection

Range*3

Standard

200~5000 ppm

200~5000 ppm

200~5000 ppm

5~25 vol%

10~25 vol%

 

Option

100 ppm~

50 ppm~

100 ppm~

-

-

Range Ratio

Within a factor of 10

Within a factor of 10

Within a factor of 10

Within a factor of 5

Within a factor of 2.5

Repeatability

Within 0.5% of full scale/week (with optional range, or during O2 measurement, ±1.0% of full scale/week)

Linearity (indicator error)

±1.0% of full scale

Zero drift

±1.0% of full scale/week (assuming surrounding temperature is maintained within 5 °C)
(with optional range, or O2 measurement, ±2.0% of full scale/week)

Span drift

±2.0% of full scale/week (assuming surrounding temperature is maintained within 5°)

Response time*4

Within 60 seconds (Td + T90 from equipment intake area) (sample flow 0.6 L/min.) (within 240 seconds for SO2 only)

Overall interference from co-existing gases

±2.0% of full scale (within standard range, with standard gas formation)

Display

Touch panel LCD (backlight) (four usable lines)

Environment
Condition

Temperature

-5 to 40 °C (away from direct sunlight and radiation heat )*5

Humidity

85% or less (no condensation)

Vibration

100 Hz, 0.3 m/s2or less

Dust

Standard environment or better

Measuring Gas Condition

Temperature

250 °C or lower

Dust

0.1 g/Nm3 or less

Standard gas composition*6

NO: 500 ppm or less; NO2: 15 ppm or less; SO2: 1000 ppm or less; SO3: 50 ppm or less;
CO: 200 ppm or less; CO2: 15% volume or less; H2O: 20% volume or less

Sampling method

Dry sampling using an electric cooler

Sample gas flow

2.5 L/min~3.0 L/min

Sample inlet tube

Teflon tubing (Ø8/Ø6 mm)

Sample gas pressure

±4.9 kPa (three points selected)
(with no sample gas back pressure)

(1) -1.96 to 4.9 kPa
(2) ±3.43 kPa
(3) -4.9 to 1.96 kPa

 

Pressure control

Pressure control uses a regulator and pump; Reduced pressure sampling; Control pressure: -4.9 kPa

Output

DC 4 to 20 mA (absolute output) (DC 0 to 16 mA/DC 0 to 1 V/DC 1 to 5V optional) Max. 12 output systems

External output

Analysis alerts, analysis warnings, range display, corrections, conservation, purging (option)
Contact capacity: DC 30 V 1 A, AC 250 V 1 A resistance load

Correction method

Dry correction, automatic correction (correction cycle: 7 days standard, can be adjusted to between 1 and 99 days), manual correction

Calibration gas

Zero gas

With measurement method authorization: N2, When there is no measurement method authorization: N2 or ambient air

O2 carrier gas

Ambient air

Span gas

Gas cylinder for each component measured (when there is no measurement method authorization: O2 or ambient air can be used)

Probe collection point filter

Flange: JIS 10K, 40 AFF; Sample probe tube length: 1000 mm; Material: SUS-316 stainless steel;
Filter element: SUS-304 stainless steel and 2um-pleated quartz wool; Electric heater: 100 VA, with water droplet proof case

Power supply

AC 100 V ±15 V(85 V~115 V)

Power frequency

50/60 Hz (switchable)

Power consumption

About 800 VA (heated piping 30m: +1100 VA; heater in tray: +300 VA)

Exterior dimensions/Mass

600 (W) x 1770 (H) x 300 (D) mm (high pressure gas cylinders, 3.4 L cylinders, maximum of 3 cylinders); About 180 kg (not including cylinders)
600 (W) x 1770 (H) x 300 (D) mm (high pressure gas cylinders, 3.4 L cylinders, maximum of 3 cylinders); About 200 kg (not including cylinders)

Materials in contract with sample gas

SUS-316 stainless steel, SUS-304 stainless steel, Teflon, polypropylene, polyethylene,
flourorubber, PVC, PVDF, and glass

Enclosure

Independent outdoor installation
Plate thickness: Main unit, doors, top plate, steel plate: 2.3 mm; Channel base: 3.2 mm; Doors: front opening; Interface: right front

Color/Finish

Semi-gloss Munsell 5Y7/1 on all inner and outer surfaces

*1: CH4 and N2O measurement are also available. Please contact us for more information.

*2: No carrier gas cylinder is required.

*3: Up to two ranges are supported for each component.

*4: Response time may vary depending on the sampling system composition.

*5: Support is available for -15 to 40 °C (cold-climate version) and 5 to 50 °C.

*6: An NH3 scrubber is available as an option for cases where a combined gas includes NH3. SO2 measurement corrected for CH4 interference is available for cases where there is CH4 in the sample gas for SO2 measurement. CO measurement corrected for N2O interference is available for cases where there is N2O in the sample gas for CO measurement.

Solid Waste Combustors and Incinerators in Solid Waste Management and Remediation Services
Solid Waste Combustors and Incinerators in Solid Waste Management and Remediation Services
Nitrous Oxide Monitoring for Greenhouse Gas Reduction
Nitrous Oxide Monitoring for Greenhouse Gas Reduction
Monitoring of SO2 for Flue Gas Desulfurization
Monitoring of SO2 for Flue Gas Desulfurization

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

AQMS
AQMS

Ambient Air Quality Monitoring System

CEMS
CEMS

Continuous Emission Monitoring System

GI-700 series
GI-700 series

Stack Gas Analyzer

PG-300 series
PG-300 series

Portable Gas Analyzer

TX-100
TX-100

Tunable Laser Gas Analyzer

VA-5000 / VA-5000WM Series
VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer

51 series
51 series

Explosion-proof Gas Analyzer

AP-370 Series
AP-370 Series

Air Pollution Monitor

APCA-370
APCA-370

Ambient Carbon Dioxide Monitor

APHA-370
APHA-370

Hydrocarbon Monitor / THC Analyser

APMA-370
APMA-370

Ambient Carbon Monoxide Monitor

APNA-370
APNA-370

Ambient NOx Monitor

APNA-370/CU-2
APNA-370/CU-2

Ambient Ammonia Monitor

APOA-370
APOA-370

Ambient Ozone Monitor

APSA-370
APSA-370

Ambient Sulfur Dioxide Monitor

APSA-370/CU-1
APSA-370/CU-1

Ambient Hydrogen Sulfide Monitor

AQMS
AQMS

Ambient Air Quality Monitoring System

CEMS
CEMS

Continuous Emission Monitoring System

FTX-ONE-CL
FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

GA-370
GA-370

Trace Gas Monitor

GI-700 series
GI-700 series

Stack Gas Analyzer

IR-300
IR-300

Vapor Concentration Monitor

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

PG-300 series
PG-300 series

Portable Gas Analyzer

Process
Process

Process Analyzer System

TX-100
TX-100

Tunable Laser Gas Analyzer

VA-5000 / VA-5000WM Series
VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer

51 series
51 series

Explosion-proof Gas Analyzer

AP-370 Series
AP-370 Series

Air Pollution Monitor

AP-380 Series
AP-380 Series

Air Quality Monitor

APCA-370
APCA-370

Ambient Carbon Dioxide Monitor

APMA-370
APMA-370

Ambient Carbon Monoxide Monitor

CEMS
CEMS

Continuous Emission Monitoring System

EMGA-921
EMGA-921

Hydrogen Analyzer

EMGA-Expert
EMGA-Expert

Oxygen/Nitrogen/Hydrogen Analyzer
(Flagship High-Accuracy Model)

EMGA-Pro
EMGA-Pro

Oxygen/Nitrogen Analyzer (Entry Model)

EMIA-Expert
EMIA-Expert

Carbon/Sulfur Analyzer
(Flagship High-Accuracy Model)

EMIA-Pro
EMIA-Pro

Carbon/Sulfur Analyzer (Entry Model)

EMIA-Step
EMIA-Step

Carbon/Sulfur Analyzer (Tubular Electric Resistance Heating Furnace Model)

ENDA-7000 Series
ENDA-7000 Series

Stack Gas Analyzer

GA-370
GA-370

Trace Gas Monitor

GI-700 series
GI-700 series

Stack Gas Analyzer

IR-300
IR-300

Vapor Concentration Monitor

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

LO-300
LO-300

Laser scanning oil film detector

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

OCMA-500
OCMA-500

Oil content analyzer

OCMA-550
OCMA-550

Oil content analyzer

PG-300 series
PG-300 series

Portable Gas Analyzer

TCA-5000
TCA-5000

Hydrogen Gas Analyzer

TX-100
TX-100

Tunable Laser Gas Analyzer

VA-5000 / VA-5000WM Series
VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer

Water & Liquid Corporate