Measures the density of the ozone fluid that is used for cleaning and oxide film formation, etc. This is an dessolved ozone concentration monitor that can be attached to a main pipe and allows continuous measurement. No bypass line is required for measurement.  

기능

  • Can be attached in a line
  • Selectable from three pipe diameter types
  • Transmission output with any settings
  • Can change the number of digits below the decimal point
  • Zero-point stability
  • Compact sensor size
  • 24V DC power supply
  • Can withstand 0.5 MPa pressure
  • Remote zero calibration function
  • PFA, quartz, and PTFE are used as materials for contact with fluids

제조원 HORIBA Advanced Techno

사양

Model

Converter: OZ-96 Detector: CZ-10i/40i/100i/200i/300i

Measurement target

Ozone concentration in pure water

Measurement principle

UV absorption (254 nm)

Measuring range

CZ-10i: 0-10 mg/L CZ-40i: 0-40 mg/L CZ-100i: 0-100 mg/L (Standard) CZ-200i: 0-200 mg/L CZ-300i: 0-300 mg/L

Reproducibility

Within ±0.2%FS

Stability

Zero point drift: Within ±0.05%FS/day

Transmission output

4-20 mA DC or 0-16 mA DC Isolated input/output type Maximum load resistance: 600Ω

Transmission output range

Arbitrarily set between -10% and +110% of the measuring range

Contact output

3ch contact a output Capacity: 24V DC, 1A max (Resistance load) Functional assignment from upper limit, lower limit, FAIL, and UV LOW alarms Setting of alarm delay time: 0-60 seconds Holding during calibration/reset selection Remote zero calibration judgment signal: If the zero calibration result is normal, the contact is closed while the zero calibration command is being input.

Contact input

Calibration is performed immediately after the zero calibration command is received. Holding during reception

Calibration function

Zero point calibration, span sensitivity adjustment, span check, signal level check function

Ambient temperature

5-40°C

Humidity

85% or less (Perform purge if the piping tube condensates.)

Power supply

24V DC 15W

Converter structure

Panel mounted: DIN 96 x 96 Indoor installation case: SUS304 Panel: ABS

External dimensions

Converter: 96 (W) x 96 (H) x 145 (D) mm Detector: 80 (W) x 159 (H) x 154 (D) mm (excluding projections)

Weight

Converter: Approx. 700 g Detector: Approx. 2 kg

Sampling conditions

Pressure: Within 0.5 MPa Flow rate: 1/2 inch: 10 L/min 3/4 inch: 40 L/min 1 inch: 100 L/min

Detector

Light source: Low-pressure mercury lamp Detector: Silicon photocell Chemical contact material: PFA, quartz glass, PTFE

Scramble

Standard: PFA 3/4 inch Option: 1/2, 1 inch tube

Purge mouth

6-dia. tube Flow rate: 100 mL/min

Attachment

Exclusive-use cable: ZK-05 Standard: 5 m, Option: 3 m,10 m, 20 m

Expendable

Low-pressure mercury lamp Life cycle: 2 years (Guaranteed life: 1 year)

Compliance

CE marking