CRITERION D500

Pressure Insensitive Mass Flow Module D500

Pressure Insensitive Mass Flow Module

Criterion D500는 Pressure Insensitive Mass Flow Module입니다. 이 Pressure Insensitibe Mass Flow Module은 차압 감지 및 Piezo actuator valve와 함께 장착됩니다. Criterion D500에서 제공하는 높은 수준의 성능은 압력에 민감하지 않고 다중 범위/다중 가스/다중 압력, G-LIFE(Integrated Flow Restrictator Equiation의 가스법 검사) 자가 진단 기능, 높은 정확도, 빠른 응답, 넓은 범위 및 모든 금속 등 다양한 고급 반도체 제조 공정에 사용할 수 있습니다.

여기에서 MFC 비교 차트를 확인하십시오.

Segment: Semiconductor
Division: Fluid Control
Manufacturing Company: HORIBA STEC, Co., Ltd.
  • Pressure Insensitive Performance
    A new high-performance Pressure Insensitive function provides a simplified gas supply system
  • Multi-range, multi-gas, multi-pressure solution
    The new functions allow the user to change gas type, Full-scale flow rate, and supply pressure range
  • G-LIFE (Gas Law check of Integrated Flow restrictor Equation) Self-Diagnosis function
    The advanced process health monitoring function allows operators to conduct their own tests, typically in three seconds or less for improved throughput
  • High Accuracy
    Flow rate accuracy for process gas has been improved with an advanced three-dimensional adjustment
  • Fast Response
    Response: < 0.8 second
    Accurate, stable flow control can be achieved 
  • Dynamic Range
    Wide control range: 0.2% F.S. to 100% F.S.

 

Technical Article

Pressure-Based Mass Flow Control Module CRITERION D507 Series (1.7MB)

Abstract
"Recently, with the increase of application of a semiconductor device according to IoT, the latest semiconductor factories are focusing to minimize the downtime of the apparatus. Therefore, for the purpose of failure pre-detection of semiconductor tools and its components, the managed parameters of semiconductor process are increased, and its specification is getting tighter. In order to satisfy the required control criteria, the mass flow control module is required to have high-speed communication and failure pre-detecting function as well as flow rate accuracy and reproducibility, inlet pressure insensitivity performance. D507 series is lined up on D500 series to meet strict management at recent semiconductor factory."

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Product accessories

Related products

CRITERION D500
CRITERION D500

Pressure Insensitive Mass Flow Module

CVS-ONE
CVS-ONE

희석 배기가스 분석기

D700MG
D700MG

High Speed & Precision Pressure Insensitive Mass Flow Module

D700WR
D700WR

Wide Range Pressure Insensitive Mass Flow Module

DZ-100
DZ-100

Ultra-thin Mass Flow Controller

EXFM-ONE
EXFM-ONE

초음파 배기 유량계

FS-3000
FS-3000

Thermal Flow Splitter

High Temperature Digital Mass Flow Controller SEC-8000F/D series
High Temperature Digital Mass Flow Controller SEC-8000F/D series

High Temperature Digital Mass Flow Controller

LE Series
LE Series

Large Flow Liquid Source Vaporization Control System

MV-2000
MV-2000

Mixed Injection System Liquid Vaporizer

S48 Series
S48 Series

General Purpose Mass Flow Controller

SEC-400 Series
SEC-400 Series

Mass Flow Controller

XF Series
XF Series

Digital Liquid Mass Flow Meters

CRITERION D500
CRITERION D500

Pressure Insensitive Mass Flow Module

D700MG
D700MG

High Speed & Precision Pressure Insensitive Mass Flow Module

D700WR
D700WR

Wide Range Pressure Insensitive Mass Flow Module

DZ-100
DZ-100

Ultra-thin Mass Flow Controller

VG-200S
VG-200S

Capacitance Manometer

XF Series
XF Series

Digital Liquid Mass Flow Meters

Corporate