EM-D5000 dust concentration and opacity monitor

Overview

EM-D5100 dust concentration / opacity monitor measure correlation between manual analysis and absorbance continuously. It employs light transmission method to be built in while LED and auto collimation function, which enables long-tem stability monitoring. Measuring value(opacity %, absorbance, mg/m3) can be switchable from LCD display.

Features

  • Stabilize and long life light source according to SWBD (super wide band diode) employment.
  • Light maintain Parallel reflection at all time according to auto collimation function.
  • Auto zero calibration function (automated detection to lens contamination).

Manufactured by HORIBA

Specifications

EM-D5100

Measuring range

Dust

0-300 mg/m3~0-4800 mg/m3 (Duct diameter: 1m)

Opacity

0-20%~0-100%

Lower detectable limit

3% of F.S.

Linearity

2% of F.S.

Temperature/Humidity

-20 ℃~50℃ / 95% RH or less

Sample gas condition

Temperature

Saturated temperature of sample gas water volume

Water

Dew condensation or less

Pressure

-5~2kPa

Particle diameter

4µm or less

Output

 

DC4-20mA (2 systems)

Auto zero calibration

Arbitrarily setting available from 1 to 99 hours (per 1 hour)

Mass

Control box

approx. 5kg

Photo transmitter

approx. 11kg

Photo receiver

approx. 7kg

Splash-proof construction

IP65

 Purge air unit

 

Supply air volume

approx. 80 to 90 m3/h

Mass

approx. 12kg / set

Splash-proof construction

IP55