EMIA-V series Carbon/Sulfur Combustion Analyzer

Overview

The EMIA-V series measures carbon and sulfur extracted during combustion in a programmable High Frequency furnace without conversion. Combustion control is achieved through the use of the high-frequency induction furnace method. Appropriate heat-control in accordance with the analysis objective enables high-precision analysis for all types of samples. A variety of models allow you to select the furnace system that is best suited to your target samples and application.

  • EMIA-820V C/S analyzer: High performance analyzers with outstanding accuracy of less than 0.3ppm
  • EMIA-320V C/S analyzer: Standard performance analyzers for wide range of applications.
  • EMIA-220V C/S analyzer: Practical analyzers ideal for production and quality control.

Features

  • "Auto cleaner" mechanism reduced maintenance works
    (Standard for 820V, Option for 320V and220V)
  • The Dust filter heating mechanism provides stable analysis with extremely low gas absorption
    (820V only)
  • Real-time simultaneous detection of CO/CO2/SO2 without an oxidizing (COCO2) or SO3 trapping reagents.
  • Wide variety of self diagnostics
  • Programmed temperature curve for optimizing combustion.
  • Choose from standard or wide range models to suit your application requirements.

Manufactured by HORIBA

Specifications

EMIA-820V series
EMIA-820V:Simultaneous carbon/sulfur analysis
EMIA-821V:
Carbon analysis
EMIA-822V: Sulfur analysis

Principle:
NDIR/ Non Dispersive Infrared Gas Anaryzer
High-frequency furnace method in oxygen flow

Range: Carbon: 0-6,0%, Sulfur: 0-1,0%
Up to 100% wt is possible by decreasing the sample weight.

Accuracy
Carbon:
0.0020%(m/m) below sample>>> σn-1≦0.00003%(m/m)
0.0020 %(m/m) and more sample>>> σn-1≦0.0001 %(m/m)
or V≦0.5%

Sulfur:
0.0020%(m/m) below sample>>> σn-1≦0.00003%(m/m)
0.0020 %(m/m) and more sample>>> σn-1≦0.0001 %(m/m)
or V≦0.75%

Sample weight: 1,0g standard

Sensitivit: 0,01ppm

Analysis time: Normally 30 to 60 seconds(after combustion),varies according to the characteristics of the samples

Calibration
One-point or multi-point calibration using standard sample

Combustion furnace method/furnace structure
High-frequency induction furnace method with combustion control function (patent pending)
Anode output: 2300W
Frequency: 20MHz
Plate current: Settable up to 500mA 
Automatic control possible (10 slopes maximum)
Constant dust filter heating function

Operation gas
Oxygen purity: More than 99.5%
Dry air or nitrogen: Supply pressure 0.35MPa

Functions
Interrupt analysis
Self diagnosis
Data storage(Measurement results)
Memory of calibration curve and measurement conditions
Statistic calculation

Automatic cleaning mechanism: Built-in as standard

Oxygen gas purifying unit: Built-in as standard

Power
Main unit: AC200/220/240V  5kVA  50/60Hz
PC: AC100V, 120/200/220/240V  0,5kVA  50/60Hz

Dimensions: 560(W)×927(D)×950(H)mm Approx.170 kg
--------------------------------------------------------------------------------------------------------

EMIA-320V series
EMIA-320V:Simultaneous carbon/sulfur analysis
EMIA-321V:Carbon analysis
EMIA-322V:Sulfur analysis

Principle:
NDIR/ Non Dispersive Infrared Gas Anaryzer
High-frequency furnace method in oxygen flow

Range:Carbon: 0-6,0%, Sulfur: 0-1,0%
Up to 100% wt is possible by decreasing the sample weight.

Accuracy
Carbon: σn-1≦0.0002 %(m/m) or CV≦1.0%
Sulfur: σn-1≦0.0002 %(m/m) or CV≦1.5%

Sample weight: 1,0g standard

Sensitivity: 0,1ppm

Analysis time
Normally 30 to 60 seconds(after combustion),varies according to the characteristics of the samples

Calibration: One-point or multi-point calibration using standard sample

Combustion furnace method/furnace structure
High-frequency induction furnace method with combustion control function (patent pending)
Anode output: 2300W
Frequency: 20MHz
Plate current: Settable up to 500mA 
Automatic control possible (10 slopes maximum)

Operation gas
Oxygen purity: More than 99.5%
Dry air or nitrogen: Supply pressure 0.35MPa

Functions
Interrupt analysis
Self diagnosis
Data storage(Measurement results)
Memory of calibration curve and measurement conditions
Statistic calculation

Automatic cleaning mechanism: Option

Oxygen gas purifying unit: Option

Power
Main unit: AC200/220/240V  5kVA  50/60Hz
PC: AC100V, 120/200/220/240V  0,5kVA  50/60Hz

Dimensions: 560(W)×885(D)×820(H)mm Approx.170 kg
--------------------------------------------------------------------------------------------------------

EMIA-220V series
EMIA-220V:Simultaneous carbon/sulfur analysis
EMIA-221V:Carbon analysis
EMIA-222V:Sulfur analysis

Principle
NDIR/ Non Dispersive Infrared Gas Anaryzer
High-frequency furnace method in oxygen flow

Range: Carbon: 0-6,0%, Sulfur: 0-1,0%
Up to 100% wt is possible by decreasing the sample weight.

Accuracy
Carbon: σn-1≦0.0005 %(m/m) or CV≦1.0%
Sulfur: σn-1≦0.0005 %(m/m) or CV≦1.5%

Sample weight: 1,0g standard

Sensitivity:1ppm

Analysis time
Normally 30 to 60 seconds(after combustion), varies according to the characteristics of the samples

Calibration
One-point or multi-point calibration using standard sample

Combustion furnace method/furnace structure
High-frequency induction furnace method with combustion control function (patent pending)
Anode output: 2300W
Frequency: 20MHz
Plate current: Settable up to 500mA 
Automatic control possible (10 slopes maximum)

Operation gas
Oxygen purity: More than 99.5%
Dry air or nitrogen: Supply pressure 0.35MPa

Functions
Interrupt analysis
Self diagnosis
Data storage(Measurement results)
Memory of calibration curve and measurement conditions
Statistic calculation

Automatic cleaning mechanism: No available

Oxygen gas purifying unit: No available

Power
Main unit: AC200/220/240V  5kVA  50/60Hz
PC: AC100V, 120/200/220/240V  0,5kVA  50/60Hz

Dimensions: 560(W)×927(D)×950(H)mm Approx.170 kg

Schematics

EMIA-Vseries Dimensional outline drawing (mm)

Related Products

EMIA-8100 series

EMIA-8100 series equipped with electrical resistance furnace measures carbon and sulfur contained...

EMIA-110

Elemental analysis plays an extremely important role in quality control in many industries include...

EMGA-920

This is an oxygen and nitrogen elemental analyzer with high accuracy and repeatability suiting to...

EMGA-620W

The HORIBA EMGA-620W Series determine the oxygen and nitrogen contained in ferrous and non-ferrous...

EMGA-620WC

The HORIBA EMGA-620W/C Series determines the high concentration oxygen and nitrogen (up to 60%)...

EMGA-600W

The HORIBA EMGA-600 is a combined model between ON and H analyzers and determines the oxygen,...

SLFA-UV21A

HORIBA's SLFA-UV21A is the latest sulfur analyzer instrument that reflects the demanding needs to...

SLFA-2100/2800

The SLFA-2100/2800 are designed specifically to meet the recent demanding needs of measuring the...

SLFA-20

The SLFA-20 are designed specifically to meet the recent demanding needs of measuring the new low...

XGT-1000WR/1100WR

XGT-1000WR are specially designed for WEEE/RoHS, ELV and Chinese RoHS for the high sensitivity...

XGT-1700WR

New line up of XGT-1000WRseries with high performance functions and increased sensitivity. ...

XGT-5000WR

High sensitivity XRF qualitative and quantitative analysis with an X-ray imaging...

XGT-5700WR

New line up of XGT-5000WR with high performance functions and increased sensitivity. Maintain the...

XGT-7000

Single point analysis and automated hyperspectral imaging.

Dual vacuum modes.

Spot sizes from 1.2...

XGT-5000

Single point analysis and automated imaging.

Atmospheric pressure analysis.

Spot sizes from 1.2...

MESA-500W

MESA-500W handles solid, liquid and powder samples with “One touch” fully automatic operation that...

The GD-Profiler 2™ provides fast, simultaneous analysis of all elements of interest including the...

The HORIBA Jobin Yvon GD-Profiler HR™ gives the optimum in terms of resolution and number of...

High Performance ICP-OES

The ULTIMA 2 offers the highest performance on the market. Specially defined for difficult samples...

High performance simultaneous ICP-OES

The ULTIMA 2C Series of Combination ICP spectrometers offers the ultimate in performance from the...

Assistance tools with ICP-OES

ACTIVA-M, a bronze award winner for best new product at Pittcon 2007 as Master in multi-line...

CCD detection ICP-OES

ACTIVA-S maintains the Strengths of HORIBA Scientific ICP-OES Spectrometers while incorporating...

Low cost  ICP-OES

The JY 2000 2 offers exceptional value with pricing designed to meet even the most challenging...