EMIA-110 Carbon Combustion Analyzer

Overview

Elemental analysis plays an extremely important role in quality control in many industries include not only steel and non ferrous metals but also ceramics and catalysts.

The EMIA-110 equipped with electrical resistance furnace measures carbon in these samples by NDIR and supports quality control.

This model offers low cost performance and decrease running cost by HORIBA original NDIR design without platinum catalysis and removing SO3 unit.

Features

  • High efficiency and low cost performance
  • Compact design for easy installation
  • Automatic calibration by Microcomputer
  • Speedy analysis – 20 to 60 sec after combustion
  • Selectable combustion extraction temperature provides for broad range of application
  • Stability and high accuracy analysis for long term

Manufactured by HORIBA

Specifications

Model

EMIA-110 (Available only Japan)

 

Carbon analysis

Principle

NDIR/ Non Dispersive Infrared Gas Anaryzer

 

Tube-shaped electric resistance furnace method
in oxygen flow

Samples

Metals, Cement, Ceramics, Coals etc

Range

Carbon: 0-9.999%

 

Up to 100% wt is possible by decreasing
the sample weight.

Accuracy

Carbon

 

σn-1≦0.001 %(m/m) or CV≦1.5%,
whichever is greater

Sample weight

0.5g standard

Sensitivity

0.001% (10ppm)

Analysis time

Approx. 20-60 sec from combustion to display

Calibration

Automatic using standard sample

Display

DPM in wt% and printer

Weight compensation

By digital switch, weight input range: 0.001-5.0g
Automatic with optional electronic balance

Combustion furnace

Tube-shaped electric resistance furnace
Operating temperature range: 500 to 1350°C
Temperature rise time: Approx. 30min from room
temperature to 1350°C
Inner diameter of combustion tube: 20Ф

Combustion time setting

By digital switches (Up to 999sec at Max)

Operation gas

Oxygen purity: More than 99.9%

External output

1V DC

Power

Combustion unit:
AC200/220V/240V  4kVA  50/60Hz

Control unit:
AC100/115/200/220/240V  0,5kVA  50/60Hz

Grounding

Apply independent ground resistance
less than 10Ω

Dimensions

Control unit: 440(W)×540(D)×239(H)mm 
Approx.42 kg
Combustion uniut: 490(W)×650(D)×570(H)mm
Approx.48 kg

Schematics

EMIA-110 Dimensional outline drawing of the combustion units
EMIA-110 Dimensional outline drawing of the measurement units

Related Products

EMIA-V series

The HORIBA EMIA-V series determine the carbon and sulfur contained in steels, nonferrous metals,...

EMIA-8100 series

EMIA-8100 series equipped with electrical resistance furnace measures carbon and sulfur contained...

EMGA-920

This is an oxygen and nitrogen elemental analyzer with high accuracy and repeatability suiting to...

EMGA-620W

The HORIBA EMGA-620W Series determine the oxygen and nitrogen contained in ferrous and non-ferrous...

EMGA-620WC

The HORIBA EMGA-620W/C Series determines the high concentration oxygen and nitrogen (up to 60%)...

EMGA-600W

The HORIBA EMGA-600 is a combined model between ON and H analyzers and determines the oxygen,...

SLFA-UV21A

HORIBA's SLFA-UV21A is the latest sulfur analyzer instrument that reflects the demanding needs to...

SLFA-20

The SLFA-20 are designed specifically to meet the recent demanding needs of measuring the new low...

SLFA-2100/2800

The SLFA-2100/2800 are designed specifically to meet the recent demanding needs of measuring the...

XGT-1000WR/1100WR

XGT-1000WR are specially designed for WEEE/RoHS, ELV and Chinese RoHS for the high sensitivity...

XGT-1700WR

New line up of XGT-1000WRseries with high performance functions and increased sensitivity. ...

XGT-5000WR

High sensitivity XRF qualitative and quantitative analysis with an X-ray imaging...

XGT-5700WR

New line up of XGT-5000WR with high performance functions and increased sensitivity. Maintain the...

XGT-5000

Single point analysis and automated imaging.

Atmospheric pressure analysis.

Spot sizes from 1.2...

XGT-7000

Single point analysis and automated hyperspectral imaging.

Dual vacuum modes.

Spot sizes from 1.2...

High performance simultaneous ICP-OES

The ULTIMA 2C Series of Combination ICP spectrometers offers the ultimate in performance from the...

High Performance ICP-OES

The ULTIMA 2 offers the highest performance on the market. Specially defined for difficult samples...

Assistance tools with ICP-OES

ACTIVA-M, a bronze award winner for best new product at Pittcon 2007 as Master in multi-line...

CCD detection ICP-OES

ACTIVA-S maintains the Strengths of HORIBA Scientific ICP-OES Spectrometers while incorporating...

Low cost  ICP-OES

The JY 2000 2 offers exceptional value with pricing designed to meet even the most challenging...