Fluorescence Spectroscopy
See Us at
- Advanced Materials Characterization Workshop - June 6th-7th
- Biofinders Texas Medical Center Commons- June 12th
- FluoroFest - August 1st - 3rd
- Biofinders University of VA School of Medicine - August 7th
- Biofinders VA Tech Corporate Research Park - August 8th
- Biofinders Fralin Life Sciences Institute - August 9th
News
- Aqualog CDOM Fluorometer Wins Award as one of Best New Instruments in 2011...Read more
- HORIBA Scientific and NKT Photonics Introduce the World’s First Commercial Integrated Supercontinuum Powered Spectrofluorometers... Read more
- Aqualog®, the only simultaneous absorbance and fluorescence system, measures CDOM (colored dissolved organic matter) in water 100 times faster than previous fluorescence methods...Read more
- World's First 100MHz Picosecond Diode Source With USB Interface and Plug-and-Play Interchangeable Heads ...Read more
TBX
Overview
The TBX is a compact single-photon detection module containing all the electronics necessary to detect single photons with picosecond accuracy. The module contains a fast rise-time photomultiplier (PMT), wide bandwidth GHz pre-amplifier, picosecond constant fraction discriminator (CFD) and regulated high voltage supply, all in one compact, fully integrated package.
The TBX is the first, and only, product to integrate all of the above functions into one module. The casing is machined from metal and gold-plated to achieve the highest level of electromagnetic shielding. Optical coupling is via a custom 40mm bayonet which allows easy interchange while still providing a light-tight seal.
There are three different models available for the TBX series of photon detection modules; TBX-650, TBX-850C and TBX-900C. The TBX-850C and TBX-900C have extended red sensitivity and are thermoelectrically cooled.
Due to its high level of integration, the TBX is an easy retrofit to existing systems and is easer to use than a SPAD module because the active detection area is many times bigger.
Applications include:
- Time-resolved fluorescence detection
- Chemi-luminescence detection
- Bioluminescence
- Single molecule detection
- Photon correlation spectroscopy
- LIDAR
- Particle sizing
- Adaptive optics
- Microscopy
- General purpose photon counting and low light level detection
Manufactured by HORIBA Scientific
Specifications
Model | Spectral response | Peak response | Typical dark counts | Transient Time Spread | Thermoelectric cooled |
|---|---|---|---|---|---|
TBX-650 | 185-650nm | 420nm | <80cps | <250ps | No (not required) |
TBX-850C | 250-850nm | 400nm | <50cps | 150ps typical (200ps max.) | Yes |
TBX-900C | 300-900nm | 630nm | <500cps typical (1000cps max) | 150ps typical | Yes |
Specifications and appearance are subject to change without notice.