Microanalysis
FT-700 Series
Overview
Available only Japan
Obtain consistent, highly precise measurement data with the HORIBA FT-700 series of maintenance-free Fourier Transform Infrared Spectrometer
FT-700 series is the state-of-the-art spectroscopy with the Fourier Transform Infrared and provides high performance measurements to detect the functional group of organic substances. A variety of application software for the efficient analytical work is equipped. A highly accurate measurement can be easily done without maintenance works.
FT-700 series is good tool for sample measurements in electricity, electronic field, polymer, pharmaceuticals, petrochemical etc. fields.
Features
- A unique enclosed environment creates a truly moisture-resistant FT-IR
- A new long life, high intensity light source provides a superior S/N ratio(10000:1)
- The user-friendly, energy-saving design of the FT-700 series units allows them to be powered on only when needed and that means lower energy costs.
- New interferometer requires no alignment adjustments
- A multitude of high performance features for to improve operability and data reliability
- Easily create customized data analysis reports with HORIBA’s unique print layout function
- Validation software with enhanced features that dramatically improve operation for device validation efficiency
Manufactured by HORIBA
Specifications
FT-730
Meas.Wavenumber range(cm-1): 7700-350
Resolution(cm-1): 0.5, 1, 2, 4, 8, 16
S/N ratio: 10000:1
Interferometer: Michelson interferometer
Beam splitter: Ge deposited film (KBr plate with humidity-proof coating)
Infrared light source: Long life, high luminosity light source
Detector: High sensitivity pyroelectric detector (DLATGS)
Optional detector: LN2-less MCT, LN2-cooled MCT
Data sampling: Uses interference signal of He-Ne laser
Gain control: AUTO or selectable in 8 steps from x1to x128
Mirror scanning speed: 2.5, 5, 12.5, 25mm/sec
Polystyrene shutter: Standard
Sample shuttle: Option
Auto sampler: Option (with auto measurement software)
Light extraction unit: Option
Interface: SCSI-2
Conditions: Ambient temperature: 15-30 degree, Humidity: Max70%
Weight: 39kg
Power supply: AC 100/110/120/220/230/240V, 50/60Hz
Power consumption: 150VA
----------------------------------------------------------------------------------------------------
FT-720
Meas.Wavenumber range(cm-1): 7700-400
Resolution(cm-1): 1, 2, 4, 8, 16
S/N ratio: 10000:1
Interferometer: Michelson interferometer
Beam splitter: Ge deposited film (KBr plate with humidity-proof coating)
Infrared light source: Long life, high luminosity light source
Detector: High sensitivity pyroelectric detector (DLATGS)
Optional detector: -
Data sampling: Uses interference signal of He-Ne laser
Gain control: AUTO or selectable in 8 steps from x1to x128
Mirror scanning speed: 2.5, 5, 12.5, 25mm/sec
Polystyrene shutter: Standard
Sample shuttle: Option
Auto sampler: Option (with auto measurement software)
Light extraction unit: Option
Interface: SCSI-2
Conditions: Ambient temperature: 15-30 degree, Humidity: Max70%
Weight: 39kg
Power supply: AC 100/110/120/220/230/240V, 50/60Hz
Power consumption: 150VA