FLIA-101 Fluoride Ion Analyzer
Overview
The FLIA-101 Series is a lineup of units for continuously analyzing fluorine ion concentrations in the comparatively broad area of industrial waste fluids. Using a Japan Industrial Standards (JIS) ion-specific electrode method, the FLIA-100 Series, accurately measures fluorine ion concentrations in water samples that are maintained at a stable level of 5pH-6pH. The FLIA-100 Series offers fully automated calibration and washing functions, a simplified design, and few parts that require maintenance, all making for easy operation. The FLIA-100 Series allows users to analyze fluorine ion concentrations in a wide variety of ranges, from low-concentration samples (0.01ppm-1ppm) at water purification plants to high-concentration (10ppm-1,000ppm) industrial wastewater.
Features
- The units use a JIS-compliant ion electrode method.
- The units offer analysis in variety of ranges, from high concentrations (10ppm-1,000ppm) to low concentrations (0.01ppm-1ppm).
- The calibration and washing functions are fully automated, and the analysis cycle can be set from 2 to 24 hours.
- The units have alert functions for such conditions as reaching upper concentration limits, sample rejection, noncalibration, insufficient pH adjustment, calibration, and washing fluids.
Manufactured by HORIBA
Specifications
Model | FLIA-101 | FLIA-102 | |
|---|---|---|---|
Measuring Method | Continuous | Intermittent | |
Measuring Principle | Fluoride ion electrode method | ||
Measuring Range | 0.1to 10ppm/0.5 to 50ppm/1 to 100ppm/10 to 1000ppm | ||
Repeatability | ±3% of full scale (at constant temperature using standard solution of 0.1ppm or more) | ||
Stability | ±4% of full scale (at constant temperature using standard solution of 0.1ppm or more) | ||
Response Time | Approx. 5 min. for 90% response (when at calibration, concentration increased tenfold using standard solution of 1 ppm ore more | ||
Measurement Cycle | 1/2/4/6/8/12/24 hour cycles, and EXT. START | ||
Automatic Calibration | Method | 1 point calibration with standard solution of concentration approximating that of sample. | |
Cycle | Unconditional START; | 2/4/6/8/12/24 hour cycles, and EXT. START | |
Time | 40 min. | 1 hour | |
Indications | Indicated value immediately before calibration held | ||
Standard solution tank | 20 L (Usable volume 16 L due to level alarm float switch) | ||
Standard solution replenishment cycle | 1 month | 3 weeks (at calibration cycle of 12 hours) | |
Automatic Cleaning | Washing solution | Diluted hydrochloric acid | |
Cycle | Unconditional START; | Cleaning after every measurement | |
Time | 40 min. | ||
Indications | Indicated value immediately before cleaning held. | ||
Tank capacity | 20 L (Usable volume 16 L due to level alarm float switch) | ||
Consumption | 3 months (12 hour cycle) | 2 weeks (at measurement cycle of 1 hour) | |
pH control solution | TISAB solution | Sodium chloride, Ferric ammonium citrate, Acetic acid, Sodium hydroxide | |
Tank capacity | 20 L (Usable volume 16 L due to level alarm float switch) | ||
pH cycle | 3 weeks | 1 months (at measurement cycle of 1 hour) | |
Alarm | Displayed on operation panel; | ||
Output | Measurement output | 4 to 20mA DC or 0 to 16mA DC | |
Alarm output | Concentration upper limit / Samle suspension / Power failure / Undergoing maintenance
| Concentration upper limit / Power failure / Undergoing maintenance
| |
Operation output | Cleaning / Calibration | Calibrating | |
Input | Start clean / Start calibration | Start measurement / Start calibration | |
Ambient conditions | Temperature | 0 to 40°C | |
Ambient humidity | 85% Rh or less | ||
Sample conditions | Temperature | 0 to 40°C | |
Flow rate | 0.5 to 3 L/min | ||
Suspended solid (SS) | 30mg/L or less (using standard overflow tank) | ||
Dimensions | Instrument | 700(w) x 500(d) x 1500(h)mm | |
Overflow tank | 290(w) x 400(d) x 500(h)mm | ||
Mass | Instrument | Approx. 150kg | |
Overflow tank | Approx. 10kg | ||
Power | AC 100V, 50 or 60 Hz | ||
Power consumption | Instrument | 0.7kVA | |
Receptacle | 0.2kVA | ||