pH Electrodes
3-in-1 Electrode (Waterproof, Silver Ion Trap Construction)
【3-in-1 electrodes incorporate a glass electrode and a reference electrode-plus a temperature compensation electrode -into a single unit】
Quick stability, and reduction of drift.
No more worries about the timing of your measurement value readings.
Stable measurement can also be achieved for highly viscous samples.
This pH electrode with temperature compensation sensor can take measurements from samples as small as 50 μL*, the smallest in the world.
283 mm length & 8 mm diameter.
The long, thin design makes this electrode perfect for measuring in large containers and test tubes.
- 1
ISFET Electrode
The sensor is located on the flat surface of the tip, with less than a 100 μm difference from the housing.
The sharp tip can pierce solid samples to take measurements.
•Use of a semiconductor sensor means there are no concerns that the electrode will be damaged.•Waterproof•Pb free
(Recommended)For measuring inside foodstuffs, such...
Replacement for 0030-10D
Replacement for 0040-10D
- 1
3-in-1 Electrode
Cased in a plastic body to enable field measurements.The slide-type internal solution filler permits submerged measurements in depths up to 1m (for up to 30 minutes)
WaterproofPb free
(Recommended)Suitable for measurements for...
Uses a sleeve for the liquid junction, improving the stability and repeatability. For measuring pH at high accuracy. (Standard accessory for model F-24II.)
Uses a glass membrane highly sensitive to lowconductivity water and non-aqueous solvents. Movable sleeve used at the liquid junction.
Needle electrode allows measurement of aqueous solutions too.
- 1
Combination Electrodes
【A combination electrode incorporating a glass electrode and a reference electrode into single unit. Please use combination electrode with temperature compensation electrode.】
For measuring pH of a small amount of sample in a slender tube (more than 3.5 mm dia.) such as a NMR test tube.
Since the pH response membrane and the liquid junction are located on the same surface, pH values on the surfaces of skin, leather, paper, and leaves can be measured.
- 1
Glass Electrodes
【Reference electrodes and temperature compensation electrodes are needed for measurement glass electrode is used.】
Very durable minimum alkali errors. Most widely used for general pH measurements.
Uses a glass membrane highly sensitive to lowconductivity water and nonaqueous solvents. Can also be used for ordinary pH measurement.
- 1
Reference Electrodes
Suitable for a wide range of pH measurements since the resistance of the liquid junciton is small.
Suitable for measurements of liquid other than normal aqueous solutions, such as suspensions, emulsions, paste, and non-aqueous solutions. When the potassium chloride solution of the internal solution reacts with the sample,...
- 1
Temperature Compensation Electrodes
Used to automatically compensate the changes in the electromotive force of the pH electrode due to temperatures and also to measure temperatures.