Elemental Analyzers
ACTIVA S, The Art in ICP-OES Spectrometer
Overview
ICP-OES Spectrometer with CCD Detection
ACTIVA-S maintains the Strengths of HORIBA Scientific ICP-OES Spectrometers while incorporating advanced CCD technology, thus offering Simplicity in a high performance ICP-OES Spectrometer:
- High Scientific Spectroscopy quality CCD, adapted to the Superior Total Plasma View, and offering the complete Spectral range of 160 – 800 nm.
- Reliable ICP-OES method development thanks to the proprietary S3-base database.
- Semi-quantitative analysis of all elements is performed from full Spectrum acquisition for concentration calculation, data reporting and data reprocessing
The unique HORIBA Scientific features of low noise CCD, holographic gratings, constant resolution across the full spectrum, superior vertical torch-based Total Plasma View, unique sheath gas device and low argon consumption expand the range of ICP-OES applications in correlation with the large analytical benefits:
- Few spectral interferences, few matrix effects, few memory effects allowing complex matrix, high dissolved solids or organic sample analysis
- Excellent limits of quantification thanks to simultaneous measurement of background
- Perfect reproducibility, facilitating multi-user operation
- High practical dynamic range of 107 with a linear response range of 5 decades minimum, for each line
The ACTIVA-S offers the practical use of ICP-OES analysis by first time operators or sophisticated users, through easy operation steps, for all types of applications.
Manufactured by HORIBA Scientific
Specifications
Generator | Solid-state, 40.68 MHz, water-cooled |
|---|---|
Cooling system | GenCo water chiller for the generator and the coil |
Exhaust | Direct Exhaust connection for plasma compartment |
Plasma | Fully demountable torch, 3 mm i.d. injector, 12 L/min plasma gas, 0.2 L/min sheath gas |
Sample introduction | Concentric glass nebuliser and glass cyclone spray chamber, 3-channel peristaltic pump |
Optical system | Thermo-regulated, 0.64 meter focal length, dual back-to-back gratings 4343 g/mm & 2400 g/mm used in the 1st order with optical resolution <12 pm for 160-430 nm and <22 pm for 430-800 nm |
Wavelength range | 160 – 800 nm |
Detection | Open Electrode CCD, 1024 x 256 pixels, pixel size 26 x 26 μm, Peltier cooled |
Brochures
Resources
- I need the detection limits offered by an axial or dual view ICP
- I need the best spectral resolution for difficult, line-rich matrices
- I need an introductory level ICP
- I am searching for an ICP to replace my current Atomic Absorbtion Spectrophometer
- I need fast analysis times for a high throughput laboratory
- I need the flexibility of a combined sequential and simultaneous ICP
- I need a custom instrument for a unique environment