Elemental Analyzers
ULTIMA 2
Overview
High performance ICP-OES Spectrometer
The ULTIMA 2 ICP-OES spectrometer with its innovative design provides a tool that increases lab productivity not only with fast analysis times, but with less complicated methods, shorter warm up time and high performance.
The high quality optics offer the lowest detection limits combined with the best spectral resolution. Full spectrum acquisition from 120 to 800 nm is available.
- Radial viewing and Total Plasma View provides lowest detection limits in ICP-OES spectrometry.
- Unique sheath gas feature, allows continuous analysis of 30% dissolved solids.
- Continuous wavelength coverage from 160 - 800nm standard with optional extension down to 120nm for Far UV analysis of the halogen elements or the use of alternative wavelengths.
- Unmatched spectral resolution of 5 pm at <320 nm minimizes interferences, with optional grating to further improve resolution for line rich matrices such as rare earth elements, geological or precious metals.
- Patented HDD® detection provides analysis of sub-ppb to percent level in one analysis.
- Dynamic range of up to 10 orders of magnitude using Win-IMAGE.
CLIP, save time and find easily the right line
In ICP-OES spectrometry, line-rich spectra are often observed and it is difficult to find analyte lines free of interference from all the matrix or concomitant element lines. This is especially true with matrices such as steel, tungsten, zirconium, precious metals and other complex matrices.
Usually the analyst prepares known solutions, makes profiles for each wavelength at different concentrations of the analyte and concomitant elements and finally selects a line free of interference with adequate sensitivity. This crucial step in ICP-OES method development is long and tedious. It must be conducted with great care because it can greatly influence the accuracy of the results.
HORIBA Jobin Yvon simplifies this step with CLIP (Collection of Line Intensity Profiles), which assists the analyst in the development of methods for high resolution sequential ICP-OES: no more solutions to prepare and no more profiles to acquire. The profile of each line is calculated according to the instrument’s configuration: focal length, slit combination, diffraction grating and order used. Only a few minutes are needed to select lines for every element.
Manufactured by HORIBA Scientific
Specifications
Generator | Solid-state, 40.68 MHz, water-cooled |
Cooling | GenCo cooler for generator and coil |
Exhaust | Direct exhaust connection for plasma compartment |
Plasma | Fully demountable torch, 3 mm i.d. injector, 12 l/min plasma gas, 0.2 l/min sheath gas |
Sample introduction |
|
Optical system | Optional dual back-to-back gratings with 4343 g/mm and 2400 g/mm gratings used in the 1st order with optical resolution <6 pm for 160-430 nm and <11 pm for 430-800 nm 160 – 800 nm |
Wavelength range | Optional Far UV for extended wavelength range 120 – 800 nm |
Detection | PMT detection with High Dynamic Detection system (HDD®) |
Brochures
Resources
- I need an ICP with a solid state detector
- I need a simultaneous ICP
- I need an introductory level ICP
- I am searching for an ICP to replace my current Atomic Absorbtion Spectrophometer
- I need fast analysis times for a high throughput laboratory
- I need the flexibility of a combined sequential and simultaneous ICP
- I need a custom instrument for a unique environment