ABX Micros ESV 60

Overview

  • Highly compact and lightweight
  • Micro-sampling on whole blood: 10μL
  • Precise cellular identification through electronic impedance variation method
  • Haemoglobin measurement with photometry

Features

ABX Micros ESV 60

  • External barcode reader (identification of patient samples, QC and reagents)
  • User-friendly interface (colour touch screen, virtual keyboard)
  • Data transfer with USB key (archiving to PC, upload of QC target values)
  • Unique reagent pack system
  • 10 animal species: dog, cat, horse, rat, mouse, rabbit, pig, monkey, cow and sheep

Manufactured by HORIBA ABX SAS

Specifications

Technical

Weight

30.9 lb / 16 kg

Power supply

100 V to 240 V - 50 Hz to 60 Hz

Dimensions

16.9 in x 14.2 in x 14.2 / 43 cm x 36 cm x 36 cm (HxLxP)

Printer

External

Throughput

50 tests/hour

Data Management

Complete QC menu, logs (reagents, calibration, maintenance, errors, blank cycle), easy operation

Transmission of patient & QC results to LAN (local area network)

Mono-directional connection

Memory

1000 patients results with histograms

Screen

LCD colour touch screen

 

Samples

50 tests/hour (Open Tube)

Parameters (8)

For rabbit, rat, mouse, pig, monkey, cow and sheep: WBC RBC PLT HGB HCT MCV MCH MCHC

Parameters (18)

For dog, cat and horse: WBC, LYM# & LYM%, MON# & MON%, GRA# & GRA%, EOS# & EOS%, RBC, PLT, HGB, MPV, HCT, MCV, MCH, MCHC, RDW

Graphics

PLT, RBC, WBC curves

Blood volume

CBC + 4DIFF mode: 10 μL

Stability

48 hours post-draw stability

Operating sample mode

Open tube

Identification

Alphanumeric, External barcode reader

 

Results

Parameters

Presicion (cv %)

Linearity

Cat




WBC

< 3 (at 5.5-19.5 x 103/μL)

0 - 100 x 103/μL

RBC

< 3.5 (at 5-10 x 106/μL)

0 - 12 x 106/µL

HGB

< 3.5 (at 8-15 g/dL)

0 - 900 x g/dL

HCT

< 3.5 (at 24-45 %)

0 - 25%

PLT (whole blood)

< 8.0 (at 300-800 x103/μL)

0 - 70 x 10³/µL

Dog




WBC

< 4 (at 6-17 x 103/μL)

0 - 100 x 103/μL

RBC

< 2.5 (at 5.5-8.5 x 106/μL)

0 - 10 x 106/µL

HGB

< 2.5 (at 12-18 g/dL)

0 - 900 x g/dL

HCT

< 2.5 (at 37-55 %)

0 - 25%

PLT

< 10.0 (at 200-500 x103/μL)

0 - 70 x 10³/µL

Horse




WBC

< 3 (at 5.4 - 14.3 x 103/μL)

0 - 100 x 103/μL

RBC

< 2.5 (at 6.8-12.9 x 106/μL)

0 - 12 x 106/µL

HGB

< 2.5 (at 11-19 g/dL)

0 - 900 x g/dL

HCT

< 2.5 (at 32-53 %)

0 - 25%

PLT

< 10.0 (at 100-350 x103/μL)

0 - 70 x 10³/µL

Related Products

ABX Micros ES 60

OT (Open Tube) & CT (Close Tube)

60 samples/hour (OT) & 50 samples/hour (CT)

CBC and 3 part...

Microsemi CRP LC-667G

CBC+CRP results in 4 minutes (15 tests / hour)

CBC results in 1 minute (55 tests / hour)

19...