FluoroLog - TCSPC Lifetimes on your Steady State Spectrofluorometer

Overview

Time Correlated Single Photon Counting on the World's Most Sensitive Spectrofluorometer

We start with the best steady-state optical bench from HORIBA Jobin Yvon SPEX®, add in a pulsed laser-diode or a pulsed spark source, and finish with a superior detector-module.

The Result?

The World's Most Sensitive Spectrofluorometer, with TCSPC ready to perform time-domain lifetime spectroscopy! You get the reliability and know-how of the SPEX® FluoroLog® series, together with the solid-state economy and sensitivity of IBH lifetime analysis, all in one instrument. All functions are software controlled from a host computer, giving you access to data with just a few keystrokes. A high repetition rate light source rapidly builds up a histogram of the sample's fluorescence decay.

So why use TCSPC for time-resolved experiments?

  • Variations of the excitation beam's intensity are irrelevant
  • Detects individual photons
  • No pulse-smearing from boxcar gates
  • High speed data-acquisitions
  • Digial precision, and no analog offset required for fitting results
  • The entire decay curve is examined at once

Of all the modern time-domain methods, including boxcar integration and streak cameras, TCSPC has by far the best dynamic range. If your sample lifetimes are really important, then SPEX®-IBH TCSPC is the method for you.


Manufactured by HORIBA Scientific

Specifications

Exciation Sources

Steady-State

Broadband 450-W Xenon arc lamp from UV to near-IR

TCSPC

  • Fixed-wavelength "Plug and Play" interchangeable NanoLED pulsed laser-diodes and LEDs. Wavelengths of 280, 340, 375, 405, 440, 473, 635, 650, 785 and 830 nm are available for laser-diodes. 370,455, 465, 485, 560, 590, 605, 625 for LEDs. Standard optical pulse durations are <200 ps (<100ps typical) for laser-diodes, <1.5 ns for LEDs.
  • 5000F coaxial nanosecond flashlamp with broadband output from 180-780 nm.
    Thyratron-gated spark and pulse generator (10 Hz - 100 kHz). Minimum optical pulse-width is 0.6 ns.

Spectrometers

Czerny-Turner, with classically-rulled gratings and all reflective optics. Optional double-grating spectrometers available. For standard 1200-grooves/mm.

Resolution

0.2 nm

Accuracy

± 0.5 nm

Speed

150 nm/s

Range

0 - 1300 nm

Detectors

TCSPC and Steady State

TBX-04 photomultiplier tube module, response 185 - 650 nm. Dark counts < 80 cps (< 20 cps typical). Timing jitter typically 180 ps FWHM, 250 ps maximum. Optioncal cooled extended-red detectors are available to 850 nm.

Lifetimes Measureable

TCSPC

< 100 ps to 100 µs lifetimes

MCS

< 10 µs to seconds (depending on source)

Software

Runs under Windows®

Brochures

Phase or Pulse - How to select the best Lifetime Spectrofluorometer

TCSPC on your Fluorolog Spectrofluorometer