On-Site Dissolved Oxygen Meter CD-250SC
Overview
This on-site dissolved oxygen meter realizes even more enhanced self-diagnostic functions, including detection of damaged sensor diaphragm and penetration of water into the probe, while maintaining practical functions. Sensor checks can be performed on a real-time basis during measurement for the realization of highly reliable measurement of dissolved oxygen. In addition, members of the 250 series contain a built-in cleaning timer in the converter, making it possible to eliminate the need to provide a separate timer unit in the case of using in combination with a cleaning system for realization of reduced total cost.
Features
- Self-diagnostic functions for reliable measurement
- One-touch calibration
- Automatic evaluation of sensor performance
- Salt concentration calibration function
- Automatic temperature compensation function
- Saturation measurement
- Enables combination with cleaning systems
- Large, customized LCD
- Simultaneous display of measured values and parameter settings
- Built-in cleaning system control function
Manufactured by HORIBA Advanced Techno
Specifications
Model | CD-250SC |
|---|---|
Measuring method | Galvanic battery method |
Measuring range | Dissolved oxygen: 0.00 - 20.00 mg / L |
Reproducibility | Within ± 2 % / FS (under same temperature conditions) |
Stability | Within ± 2 % / FS / week (under same temperature conditions) |
Transmission output range | 0.00 - 5.00, 0.00 - 10.00, 0.00 - 15.00, 0.00 - 20.00 (mg / L) (selectable with function setting switch) |
Contact output | No. of contacts: 3 |
Cleaning contact output (CLN) | Contact type: Semiconductor (SSR) relay, 1a |
Alarm contact output (RLY1) | Contact type: Relay contact, 1a (no-voltage contact) |
Alarm contact output (RLY2) | Contact type: Relay contact, 1c (no-voltage contact) |
Contact input | DC 4 - 20 mA, isolated input / output type |
Control operation | On / off operation, upper limit (H) or lower limit (L) (selectable with function setting switch) |
Control width | 0.01 - 1.00 mg / L (± 0.50 mg / L) |
Automatic diagnostic function | Alarm output type |
Output of invalidation of measured values | |
Diagnosis contents | System error (meter error, sensor error, power supply interruption) |
Calibration functions | Atmospheric calibration, saturated solution calibration, temperature calibration |
Additional functions | 1) Various error messages
2) Alarm on delay: Delay time setting: 0 - 15 minutes |
Temperature compensation range | 0.0 - 40.0 °C |
Salinity calibration range | 0.0 - 5.0 % |
Ambient temperature and humidity | -5 to 50 °C, 85 % RH or less |
Power supply | AC 100 - 115 V, 50 / 60 Hz, 7 VA or AC 200 - 240 V, 50 / 60 Hz, 7 VA (as per user instructions) |
Structure | Outdoor installation type: JIS C0920 protective grade: 3 (rain-proof type) |
External dimensions | 222 (W) x 180 (H) x 155 (D) (excluding mounting brackets and projections) |
Weight | Approx. 4 kg |