HORIBA Advanced Techno
HAT Products
Cleaning of pH electrode with cleaning solution and calibration with standard solution is automated, making it possible to drastically reduce maintenance work.
CODA-500: High-Performance Automatic CODMN Monitor Created Through Advanced Technology and More Than 30 Years of Accumulated Expertise
High accuracy temperature compensation CPU, simultaneous display of conductivity and temperature, and utilization of platinum temperature measuring resistor in temperature compensation element combine to offer specifications ideally suited for highly accurate conductivity measurement of pure water. Moreover, an abundance of proven sensor groups are used to monitor the quality of pure water.
The 250 series consists of dissolved oxygen meters featuring a cleaning timer built into the converter while maintaining practical functions. Elimination of the need to provide a separate timer unit in the case of using in combination with a cleaning system realizes a reduction in total cost.
This conductivity meter measures conductivity, resistivity and salt in water solutions. It is a field type, with a waterproof case, and is easy to hold and move. It enables anyone to conduct high-precision measurement, anytime...
The ESH-01-C-SN conductivity sensor, which is used in conjunction with the HE-960CW conductivity converter, is ideal for controlling conductivity in the purified water, pasteurized water, and water for injection that are used in the production of pharmaceuticals and foods and beverages.
The FES-220 Series sanitary conductivity sensors are electric sensors that target sanitation issues by employing a flat structure that keeps dirt from adhering to the tip of the sensor, and they enable continuous, high accuracy measurement in liquids of various concentrations, from purified water to cleaning solutions. The FES-220 Series, which is used in conjunction with the conductivity converter HE-960HS, demonstrates the optimum high sanitary characteristics that are ideal for the concentration and CIP management employed at food (beverage) and cosmetics plants.
Since the flow-through type sensor FES-310L has no internal protuberances, fluid flows through the sensor with exactly the same inside diameter as the pipe, thus helping reduce fluid retention and ensuring that CIP chemical fluid is drained completely, which results in higher cleaning performance.
By simply inputting the temperature constant recorded on the sensor into the instruction converter, high temperature measurement precision can be achieved.
It is also possible to perform temperature calibration in comparison with standard reference thermometers.
* ERF sensors use 3850 ppm / °C
platinum temperature resistors.
Since the flow-through type sensor FS-01FC has no internal protuberances, fluid flows through the sensor with exactly the same inside diameter as the pipe, thus helping reduce fluid retention and ensuring that CIP chemical fluid is drained completely, which results in higher cleaning performance.
Measures the conductivity ranging from purified water up to 2000 µS/cm for pharmaceuticals, food, and cosmetics applications
The HE-960HI is a wide range conductivity meter, applicable for monitoring high level conductivity concentrations in pharmaceutical, food and sanitary production water.
The HT-110 is an online TOC minitor, applicable for Purified Water (PW), Water For Injection (WFI) and Highly Purified Water (HPW). It is suitable for pharmaceutical and/or semiconductor manufacturing.
The HE-480H industrial conductivity meter is a high-concentration conductivity meter using a four-electrode method, with a wide measurement range of 0 - 50 S/m. It is suitable for a wide range of tasks, from managing the concentration of all types of medicinal solutions, to managing the concentration of liquid fertilizers used in hydroponic farming.
The HE-480C industrial conductivity meter is a low-concentration conductivity meter using a two-electrode method.
This is a highly functional model, with high-performance temperature compensation, and is applicable to a wide range of tasks, from managing pure water for use with semiconductors, to managing the quality of boiler water.
The HO-480 industrial ORP meter is an ORP converter for measuring the oxidation-reduction potential of all types of solvent.
Being combined with a lead-free sensor, it makes measurements in a way that is kind to the environment.
The HP-480 industrial pH meter is a standard type pH meter that mainly includes frequently used functions.
The HP-480PL industrial pH meter is a pH meter with a pulse proportional control function, which can drive a pulse pump directly.
The HP-480TP industrial pH meter is a pH meter with a time sharing proportional control function, making it ideal for tasks such as interval processing in any type of control process.
The HP-960FTP industrial pH meter is a high-end pH meter with a four-point alarm and a time sharing proportional control function.
It can also be linked with a cleaning device via an external input, extending its automatic operation time.
The HE-480R industrial resistivity meter features the high-precision temperature compensation function.
Its high-performance temperature compensation makes it ideal for sequential monitoring of ultra-pure water used in manufacturing processes in the semiconductor field, and many other fields, including the areas of electrical goods, foods and medicines.
This resistivity meter is ideal for such applications as the high-precision water monitoring employed at ultra-pure water plants used in semiconductor manufacturing.
They utilize newly designed, high-precision, high-stability temperature measurement circuitry and a vastly improved temperature compensation function, an important element for measuring the resistivity of ultra-pure water.
Oil film detector LO-300 scans water surface with the laser and detects the film of oil.
The OCMA-500 Oil Content Analyzer has been redesigned for even better operability, maintaining its user-friendly features. After injecting the sample, all you have to do is press a button to get the monitoring operation done...
The OCMA-505 Oil Content Analyzer has been redesigned for even better operability, maintaining its user-friendly features.After injecting the sample, all you have to do is press a button to get the monitoring operation done...
OCMA-550 to measure residual oil on components and concentrations of oil adhered on solids such as soil. Measurement can be easily made only by injecting the extracted water sample into the attached cell and setting it to the equipment. This model features a simple design which allows opening/closing of the door to setting of cell with just one hand. This is best for measurement of extracted samples such as evaluation of residual oil on components and measurement of oil contained in food.
OCMA-555 to measure residual oil on components and concentrations of oil adhered on solids such as soil. Measurement can be easily made only by injecting the extracted water sample into the attached cell and setting it to the equipment. This model features a simple design which allows opening/closing of the door to setting of cell with just one hand. This is best for measurement of extracted samples such as evaluation of residual oil on components and measurement of oil contained in food.
This field-type dissolved oxygen meter measures dissolved oxygen concentration (DO), oxygen concentration (O2), saturation (SAT.RATIO) and temperature of water solutions. It uses a laboratory sensor to enable BOD measurement....
This on-site dissolved oxygen meter realizes even more enhanced self-diagnostic functions, including detection of damaged sensor diaphragm and penetration of water into the probe, while maintaining practical functions. Sensor checks can be performed on a real-time basis during measurement for the realization of highly reliable measurement of dissolved oxygen. In addition, members of the 250 series contain a built-in cleaning timer in the converter, making it possible to eliminate the need to provide a separate timer unit in the case of using in combination with a cleaning system for realization of reduced total cost.
![]()
![]()
The OPSA-150 is a new organic pollutant monitor that uses HORIBA's proprietary Rotary Cell Length Modulation, a measuring technique incorporating 25 years of expertise.
Outdoor setup is possible because it has a rainproof structure. In addition, it features a one-touch calibration function, automatic electrode quality evaluation, and error message display. It also has an innovative design making use of a large, easy-view custom LCD.
The CP-200TP has a function that controls overshooting by varying not only the ON time (injection time), but also the cycle, as deviation becomes smaller.
The 250 series features a converter with built-in cleaning timer for practical use of functions without modification. A separate timer unit is unnecessary when used in combination with a cleaning unit thereby providing total cost-down operation.
This residual chlorine meter realizes simultaneous display of measured values and parameter settings as well as a simplified calibration procedure including a zero calibration omission function and span calibration using low-concentration samples. This makes the CR-200 optimal for measurement of residual chlorine requiring stability and accuracy.
The IF-250 Simple Fluoride Ion Monitor for use in industry provides continuous measurements of the free fluoride ion concentration in waste water and other test samples using the fluoride ion electrode method.
The unit can be used on a range of test samples with varying concentrations from 0.0 to 10.0 mg / L up to 0 to 10,000 mg / L. This makes the IF-250 the ideal unit for monitoring the treatment of waste water and effluent resulting from the semiconductor production process, as well as electronic and glass factories using fluoride in the production process.
In addition to employing a measurement system that is resistant to soiling, the CSS-250 sludge concentration meter employs a new technology for the first time in the industry for containing a cleaning mechanism inside the probe. This makes it possible to prevent sludge and hair from becoming wrapped around and becoming entangled with the probe resulting in significant improvement in cleaning efficiency and ease of maintenance. In addition, the cleaning timer is built into the converter for realization of reduced total cost.
The HD-480 industrial dissolved oxygen meter takes sequential measurements of the concentration of dissolved oxygen, which is an indicator used in the management of activated sludge tanks in waste water processing, and the quality of the water in boilers, or rivers and waterways.
As there is no need to exchange the membrane of the disposable sensor included, it is easy for anyone to use.
The HR-480 industrial residual chlorine meter takes sequential measurements of free residual chlorine, which is an indicator used in the inspection of the anti-bacterial properties of drinking water and swimming pools.
The sensor combined with uses a galvanic method with no drive section, making it highly maintainable, and producing stable measurements over a long period.
![]()
A state-of-the-art model adopting 60 years of water measurement technology, which achieves a reduction in life cycle costs, and compliance with regulations and corporate compliance.
The CP-300 is the newest addition to our lineup of pH / ORP meters offering excellent stability and temperature characteristics. The CP-300 is capable of accommodating a wide range of application fields from general wastewater monitoring to pH measurement of industrial processes.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
U-50 series Multi-parameter water quality checker enables to measure and indicate the monitoring result simultaneously up to 11 parameters with one unit.
The HQ-300 is multiparameter transmitter(1 component can be selected from pH,ORP,dissolved oxygen(DO),fluoride ion*,electrical conductivity and electrical resistivity) with the latest HART communication(protocol revision7).
*Fluoride ion is optional.