Partica mini LA-350– Compact Routine Laser Diffraction Analyzer

Overview

HORIBA's new LA-350 Laser Diffraction Particle Size Distribution Analyzer is the ideal combination of performance, price, and packaging. The LA-350 excels in applications as diverse as slurries, minerals, and paper chemistry. Based on the advanced optical design of previous LA-series analyzers, the LA-350 strikes a harmonious balance between high-functionality, easy operation, low maintenance, and cost-effectiveness.

Bench space is used efficiently due to the LA-350’s compact size (297 mm x 420 mm). The clever design and precision, high quality manufacturing ensure convenient, reliable operation and accurate results, now with a wider size range (0.1-1,000 µm).

In addition, access to world class HORIBA support and training comes with purchase of all HORIBA products. HORIBA offers scheduled service agreements, regular instructional videos, and scheduled classes. HORIBA customers not only have the best analyzers in the business ... they are the best analysts in the business.

Features

  • Range: 0.1 - 1,000 µm which matches the widest range of applications with a performance equivalent to many other full range systems.
  • Compact Size: Crowded lab? Multiple locations? The compact size preserves bench space and makes it possible to transport the instrument to different locations within a facility or ship to remote locations for on-site testing where it is not practical to purchase an analyzer.
  • Fast Analysis: The highly-refined optical design and algorithm provides measurement results in three easy steps: click, add sample, and review data. Data can be obtained in as little as ten seconds.
  • Powerful Software: The LA-350 uses the same fully featured software package as our other LA-series analyzers, providing a wide range of statistical measures, data analysis, and presentation tools.
  • Ease of Use: With automatic alignment, a built-in ultrasonic system for sample dispersion, and a powerful pumping system, combined with the automation features of the software, sample analysis on the LA-350 is extremely easy and straightforward. Sample analysis can be a one-button operation.

Benefits

  • Flexible Operation: Readily adapt to changing measurement needs with a wider size range and flexible software.
  • Simple Operation: One button operation is possible by using the methods and sequence options built into the software.
  • Fast Analysis: Get answers now with quick measurement and analysis.

Manufactured by HORIBA

Specifications

Contents

Specification

Measurement Principle

Laser diffraction and Mie light scattering theory

Size Measurement Range

0.1-1,000 μm

Analysis Time

Typical measurement takes about 10 seconds from "Measure" to "display the result".

Analysis Materials

Powders, slurries, emulsions etc.

Measurement Output

Particle size and size distribution, size related theoretical calculated values

Measurement Method

Wet method: Liquid dispersed particles with flow sampling system

Required Sample Amount

10 mg-5 g (depending on the sample size, distribution and materials)

Wet Flow System Liquid Volume

Approximately 130-230 mL

Organic Solvent Compatibility

Available in solvent resistant flow sampling version or fraction cell system (optional)

Measurement Performance Guarantee

HORIBA selected NIST traceable standard materials

Interface

USB data communication with PC

Data Processing/Results Display

Desktop or laptop PC/LCD; Printer

Operating Conditions

15° to 35° C
85% RH or less (non-condensing)

Power

AC100/120/230V, 50/60Hz, 150VA

Dimensions

W 297mm x D 420mm x H 376mm (excluding PC)

Mass

Approximately 23 kg

Optics

Light source: Laser diode 5mW, λ=650nm
Analyzer Classification: Class 1A laser product
Detectors: 64 ring detectors x 1, Silicon photo detectors x 6

Wet Sampling System

Ultrasonic: Ultrasonic probe inside of the flow system, 7 steps power adjustment
Circulation pumping system: Centrifugal pump, 15 steps of speed control
Drain: Solenoid valve
Flow cell material: Borosilicate glass

Measurement Techniques

The LA-350 uses Mie Scattering Theory (laser diffraction) to measure particle size over the range of 0.1-1,000 µm. A 650nm solid-state, diode laser is focused by an automatic alignment system through the measurement cell. Light is scattered by the particles to a 70-element detector system, including high-angle and back-scatter detectors for a full angular light intensity distribution. The thick, cast-aluminum optical bench provides stable, high-precision results. For more information on laser diffraction, visit our Laser Diffraction Technique page.

Accessories

  • Fraction Cell/Holder: The 5 mL cuvette-type Fraction Cell allows measurement of small volumes of liquid suspensions, making it is perfect for measuring very valuable or extremely small or hazardous samples.

Related Products

LA-960

The LA-960V2 uses Mie Scattering (laser diffraction) to measure particle size of suspensions or dry...

SZ-100 Nanopartica Series Instruments

Industry's widest range and highest precision measurement instrument for Nanoparticle...