FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

This small device can accurately measure up to 28 components. such as nitrogen compounds, aldehydes, and alcohol in engine diluted exhaust gas.

Segment: Automotive
Produktionsfirma: HORIBA, Ltd.

Fast Response and Compact Size FTIR Analyzer for the Simultaneous Measurement of Multiple Components of Engine Exhaust Gas

Offers a 5Hz sampling rate and simultaneously measure the concentrations of multiple components including NH3, CH4 and CO2, engine diluted exhaust gas using the Fourier Transform Infrared (FTIR) method in combination with multivariate analysis algorithm.

Applications

Latest Regulations
・Measurements compliant with the latest US EPA regulations*: LDV Tier 3 regulation N2O certification / NMOG certification (NMOG is NG vehicle only), Stationary engine VOC regulation NMNEHC*5 certification (NG engine only) is possible.
・GTR No.15 compliant measurement*: GTR No.15 (Global Unified Technical Regulations for LDV Exhaust Gas Testing) Compatible with measurement methods such as HCHO, C2H5OH, N2O, etc.
・Engine / automobile development for Euro 7*:For R & D applications in anticipation of EU LDV next regulations (measurement of HCHO, C2H5OH, N2O, etc.)

* Please contact our sales staff for details.  ** NMNEHC is an abbreviation for non-methane non-ethane hydrocarbon.

 

Features

Dilution measurement and mass calculation by high-precision measurement
Mass calculation is possible by evaluation in combination with a constant volume dilution sampling device and a test automation system.

Low Sampling Flow Rate
Minimize bag line sampling flow and easily integrate into existing systems.

Compact Design
Approx. 1/2 the installation area and weight.* Improved freedom of layout and maintainability in the lab.

* At the size of the footprint

Outline

 FTX-ONE-CL
Measurement targetExhaust gas from internal combustion engine (Dilute measurement)
Target components*1Max. 28 components
Target components sets*2Standard set : Gasoline / Diesel vehicle
CNG set
PrincipleFourier Transform Infrared (FTIR)
Sampling line temperature113 °C ± 3 °C
Sampling gas flow rateContinuous line: Approx. 3.0 L/min
Bag line: Approx. 1.0 L/min
Operating environmentAmbient temperature 5 - 40 °C
Ambient humidity: less than 80 % relative humidity (non condensing)
Power requirements*3Approx. 2.8 kVA as MAX.,
Approx. 2.2 kVA at stable state
Dimensions*4438(W) × 765(D) × 950(H) mm
Mass*4Approx.160 kg

*1:Select when ordering from the “Measuring Components and Ranges” table
*2:Standard combination of components and ranges, specified at time of order
*3:With heated filter, heated hose (15 m)
*4:Excluding protrusions

Measuring Components and Ranges*1

ComponentsStandard
CO0-100ppm
0-500ppm
0-2500ppm
0-1 vol%
0-5 vol%
CO20-5000ppm
0-2 vol%
0-10 vol%
NO0-100ppm
0-500ppm
0-2500ppm
NO20-100ppm
N2O0-20ppm
0-100ppm
H2O0-15 vol%
NH30-100ppm
0-500ppm
SO20-100ppm
HCHO*20-50ppm
HCOOH0-50ppm
CH3OH0-100ppm
C2H5OH0-50ppm
0-100ppm
CH3CHO0-50ppm
CH40-250ppm
C2H40-100ppm
C2H60-100ppm
1,3-C4H60-100ppm
iso-C4H80-100ppm
C6H60-250ppm
C7H80-250ppm
NOx / HC sumSum

*1: The following are optional: Add other components (methanol, ethanol, acetaldehyde, MTBE, DME, acetone and acetic acid), to interchange other components and to change ranges. Please contact HORIBA for optional arrangements.
*2: Reference component

Informationsanfrage

Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten.

* Diese Felder sind Pflichtfelder.

Related products

CVS-ONE
CVS-ONE

Constant Volume Sampler

EXFM-ONE
EXFM-ONE

Ultrasonic Exhaust Flow Meter

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

MDLT-ONE
MDLT-ONE

Micro Dilution Tunnel

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-2000SPCS series
MEXA-2000SPCS series

Solid Particle Counting System

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-730λ
MEXA-730λ

Air-to-fuel Ratio Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE PM unit
OBS-ONE PM unit

On-board Emissions Measurement System

OBS-ONE PN Unit
OBS-ONE PN Unit

On-board Emissions Measurement System

OBS-ONE SPN10 Unit
OBS-ONE SPN10 Unit

On-board SPN10 measurement for real-world

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

PTFM-1000V2
PTFM-1000V2

Pitot Tube Exhaust Flow Meter

PTFM-ONE-DT
PTFM-ONE-DT

Dual Pitot Tube Exhaust Flow Meter

Torque Matching
Torque Matching

Road-to-Rig Chassis Dyno Replication

51 series
51 series

Explosion-proof Gas Analyzer

AP-370 Serie
AP-370 Serie

Analysatoren zur Überwachung der Umgebungsluft

APCA-370
APCA-370

Kohlendioxid Analysator

APHA-370
APHA-370

THC Analysator

APMA-370
APMA-370

APMA-370 Kohlenmonoxid Analysator

APNA-370
APNA-370

APNA-370 Stickoxid Analysator

APOA-370
APOA-370

Ozon Analysator

APSA-370
APSA-370

APSA-370 Schwefeldioxid Analysator

AQMS
AQMS

Überwachungsstation für die Umgebungsluftqualität

CEMS
CEMS

Continuous Emission Monitoring System

ENDA-5000 series
ENDA-5000 series

Stack Gas Analysis System

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

GA-370
GA-370

CO, CO2, CH4 Spurengas Analysator

GI-700 series
GI-700 series

Stack Gas Analyzer

IR-300
IR-300

Vapor Concentration Monitor

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

PG-300 series
PG-300 series

Portable Gas Analyzer

Process
Process

Process Analyzer System

PX-375
PX-375

Kontinuierlich messendes Feinstaubmessgerät mit Röntgenfluoreszenzanalyse

VA-5000 / VA-5000WM Series
VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

Corporate