GI-700 series

Stack Gas Analyzer

Increase your CEMS Capabilities with a HORIBA Multi-gas Analyzer

Experience HORIBA, the Global Single Source Solutions Provider with over 50 years of technological advancements and unparalleled reliability, dependability and operability.The GI-700 stack gas analyzer is designed to continuously measure the concentrations of nitrogen oxides (NOx), sulfur dioxide (SO2), carbon monoxide (CO), carbon dioxide (CO2), oxygen (O2), and ammonia (NH3) in stack flue gas streams.

 

Abteilung: Combustion
Produktionsfirma: HORIBA, Ltd.
  • Ultimate Dependability
    Proven cross-flow modulation technique
    Continuous base line validation
     
  • Ultimate Low cost ownership
    Up to 6 gases can be measured using a single analyzer with multiple detectors. Works with a simple sampling unit having less tubing, fewer power cables. Simplified wiring translates into less time required for installation. Minimum function for the operation. Any additional functions can be added from controlling PLC.
     
  • Ultimate Sensitivity
    5 ppm High-Precision measurement (NOx, SO2 and CO) is available.
     
  • Others
    - An external converter provides for separate measurements of NO and NO2.
    - All component modules can be easily installed with in a single 19 inch case. The compact design saves space, facilitates maintenance and requires less wiring and tubing during installation.
    - Power consumption is reduced by approximately 50% as compared to systems using individual analyzers (NH3 analyzer).
     
  • User Friendly


     
  • Various Applications include:
    Stack emission monitoring, SCR control, Desulfurization control, Greenhouse gas monitoring, Boiler emissions measurements, Gas separation, Coal and gas fired emission sources,  incinerator emissions monitoring...

Model

GI-700

Component

NOx

SO2

CO

CO2

O2

NH3*3

Measurement methods*1

NDIR
CLA

NDIR
NDUV

NDIR

NDIR

MPA

CLA

Range*1

Standard

10~5000 ppm

10~5000 ppm

50~5000 ppm

5~25 vol%

10~25 vol%

 10-100
ppm

 

Optional

5 ppm~

5 ppm~

5 ppm~

10 vol%~

-

 -

Range Ratio*1

Standard1:101:101:101:51:51:10
 

Optional

1:201:201:20*21:5--

Indicated error
(Linearity)

± 1.0 % of full-scale value for each component and range (Standard range ratio)
± 2.0 % of full-scale value for each component and range (Optinonal range ratio)

Zero drift

± 1.0%/week of full scale (standard range) (if the ambient temperature change is ≤ 5°C)
± 2.0%/week of full scale (optional range and O2 carrier specification O2 analyzer) (if the ambient temperature change is ≤ 5°C)

Span drift

± 2.0%/week of full scale (if the ambient temperature change is ≤ 5°C)

Response time

T90=45s from the analyzer inlet

Interference

±2.0% of full scale

Environment
Condition

Temperature

0° to 40°C (No direct sun light or no radiation heat)

Humidity

≤ 90%

Vibration

100Hz, 0.3m/s2 or less

Dust

Less than environment standard

Measuring Gas Condition

Temperature

Ambient temperature

Dust

None

Standard gas composition

NO :Up to 5000 ppm
NO2: None
SO2: Up to 5000 ppm
SO3: None
CO :Up to 5000 ppm,
CO2:3 vol% to 15 vol%
O2  :0.2 vol% to 15 vol%
HCl : None
H2O: Saturated at 5°C

Sample inlet tube

Polytetrafluoroethylene tube (6 mm O.D./4 mm I.D.)

Sample gas pressure

Atmospheric pressure ± 4 in. W.C.

Pressure control

Not including (Vacuum regulator (-9.8 kPa))

Output(Option)

Analog output: 6 channels 4-20mA, 0-1V, 0-5V
Digital input: 8 channels 24V/10mA
Digital output: 16channels 24V/0.5A

Calibration gas

Zero gas : Nitrogen
Span gas : Gas to be measured

Carrier gas for (Oxygen analyzerNitrogen (for N2 carrier specification), Air (for air carrier specification)
Air for ozone generationDry air (saturated at ≤ -30°C)

Power supply

100 - 240 VAC (Depends on components)

Power frequency

50/ 60 Hz for common use

Power consumption

240 VA

Exterior dimensions/Mass

5U below in (H)19 in. (W)22 in. (D) / Approx. 19kg (depends on the incorporated components)

Materials in contract with sample gas

PTFE, Nylon, PP, FKM, SS304, SS316
Serial CommunicationsModbusTM, Ethernet (Modbus address will be disclosed)
*Modbus is a trademark of Schneider Electric Inc.

*1: Depends on measurement range specifications.
*2: A range ratio of 1: 40 is also possible for special applications.
*3: A range ratio of CLA NH3 and CLA NOx should be 1: 5 or less.

Informationsanfrage

Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten. * Diese Felder sind Pflichtfelder.

Related products

More AQMS

Überwachungsstation für die Umgebungsluftqualität

More CEMS

Continuous Emission Monitoring System

More ENDA-5000 series

Stack Gas Analysis System

More PG-300 series

Portable Gas Analyzer

More VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer

More 51 series

Explosion-proof Gas Analyzer

More AP-370 Serie

Analysatoren zur Überwachung der Umgebungsluft

More APCA-370

Kohlendioxid Analysator

More APHA-370

THC Analysator

More APMA-370

APMA-370 Kohlenmonoxid Analysator

More APNA-370

APNA-371 Stickoxid Analysator

More APNA-370/CU-2

Ambient Ammonium Monitor

More APOA-370

Ozon Analysator

More APSA-370

APSA-370 Schwefeldioxid Analysator

More APSA-370/CU-1

Ambient Hydrogen Sulfide Monitor

More AQMS

Überwachungsstation für die Umgebungsluftqualität

More CEMS

Continuous Emission Monitoring System

More ENDA-5000 series

Stack Gas Analysis System

More FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

More FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

More GA-370

CO, CO2, CH4 Spurengas Analysator

More IR-300

Vapor Concentration Monitor

More IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

More MEXA-1170HCLD

Heated Type NOx Analyzer

More MEXA-1170HFID

Heated Type THC Analyzer

More MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

More MEXA-1300R

Motor Exhaust Gas Analyzer

More MEXA-584L

Automotive Emission Analyzer

More MEXA-ONE

Motor Exhaust Gas Analyzer

More MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

More MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

More OBS-ONE GS Unit

On-board Emissions Measurement System

More OBS-ONE IRLAM Unit

On-board Emissions Measurement System for NH3/N2O

More PG-300 series

Portable Gas Analyzer

More Process

Process Analyzer System

More PX-375

Continuous Particulate Monitor with X-ray Fluorescence

More TX-100

Tunable Laser Gas Analyzer

More VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer

More 51 series

Explosion-proof Gas Analyzer

More AP-370 Serie

Analysatoren zur Überwachung der Umgebungsluft

More APCA-370

Kohlendioxid Analysator

More APMA-370

APMA-370 Kohlenmonoxid Analysator

More APNA-370

APNA-371 Stickoxid Analysator

More APNA-370/CU-2

Ambient Ammonium Monitor

More APOA-370

Ozon Analysator

More EMGA-920

Oxygen/Nitrogen Analyzer

More EMGA-921

Hydrogen Analyzer

More EMGA-930

Oxygen/Nitrogen/Hydrogen Analyzer

More EMGA-Expert

Oxygen/Nitrogen/Hydrogen Analyzers

More EMGA-Pro

Oxygen/Nitrogen/Hydrogen Analyzers

More EMIA-Expert

Carbon/Sulfur Analyzer

More EMIA-Pro

Carbon/Sulfur Analyzer

More EMIA-Step

Carbon/Sulfur Analyzer

More ENDA-5000 series

Stack Gas Analysis System

More GA-370

CO, CO2, CH4 Spurengas Analysator

More IR-300

Vapor Concentration Monitor

More IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

More LO-300

Laser scanning Oil Film Detector

More MEXA-1170HCLD

Heated Type NOx Analyzer

More MEXA-1300R

Motor Exhaust Gas Analyzer

More MEXA-584L

Automotive Emission Analyzer

More MEXA-ONE

Motor Exhaust Gas Analyzer

More OBS-ONE GS Unit

On-board Emissions Measurement System

More OBS-ONE IRLAM Unit

On-board Emissions Measurement System for NH3/N2O

More OCMA-500

Oil Content Analyzer

More OCMA-550

Oil Content Analyzer

More PG-300 series

Portable Gas Analyzer

More TX-100

Tunable Laser Gas Analyzer

More VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer

Corporate