MEXA-2000SPCS series

MEXA-2000SPCS - Solid Particle Counting System
MEXA-2000SPCS - Engine Vehicle Certification Testing
MEXA-2000SPCS - Partial Flow Dilution Tunnel

Solid Particle Counting System

The HORIBA MEXA-2000SPCS series measures the number of solid particles from engine exhaust gas in real-time.
The series can complete engine/vehicle certification testing in the latest regulations*1, such as Euro 6/VI and China 6/VI,along with R&D testing of engines and particulate filters by direct sampling without dilution.

*1: Please contact us for more information on the regulations that the products comply with.

Segment: Automotive
Produktionsfirma: HORIBA, Ltd.

Line-ups

  • Certification tests for the latest regulations
    MEXA-2000 / 2200SPCS
  • R&D tests with high pressure direct sampling  
    MEXA-2100 / 2300SPCS
  • SPN10 particle measurement [New Lineup]  
    (Fulfills GTR No.15, Amendment 6, SPN 10 requirements)  
    MEXA-2010/2110/2210/2310SPCS

 

Sampling methods
ModelsMEXA-2000SPCS
MEXA-2010SPCS
MEXA-210SPCS
MEXA-2110SPCS
MEXA-2200SPCS
MEXA-2210SPCS
MEXA-2300SPCS
MEXA-2310SPCS
Sampling methodFull Flow TunnelFull Flow Tunnel
Direct Sampling
Full Flow Tunnel
Partial Flow Tunnel
Full Flow Tunnel
Direct Sampling
Partial Flow Tunnel

Features

  • Compact design

• Easy to install and transport in a laboratory
• Small footprint 

        
     
       
 
  • High performance sampling system

The set DF is not affected by changes in sample pressure in the CVS or
sampling system. The VPR *1 calibration factor (PCRF *2) can be used
for many applications without specific calibration/correction of the diluters
in VPR.
*1 VPR: Volatile Particle Remover
*2 PCRF: Particle Concentration Reduction Factor

  • Various optional units

The combination of the main unit and optional units allows a wide range of applications and sampling configurations.

 For Measurement
Optional UnitsFunctions2000210022002300
Cyclone Unit (CYU) *1External CycloneBuilt-inBuilt-in
Sample Return Unit (SRU)Returning sample to CVS×××
Cooler Unit (CLU) *2Cooling detector (CPC) for high temperature conditions

For Performance Check
Optional UnitsFunctions2000210022002300
Dilution Factor Checker (DFC)Dilution factor check and flow rate calibration
Linearity Check Unit (LCU)Generating solid particles for linearity check
and penetration efficiency check
Volatile-particle Generation Unit (VGU)Generating particles for removal efficiency
check of evaporation tube

*1: For MEXA-2000/2200SPCS, select a hatted probe or an external cyclone unit set at full flow tunnel side.
*2: Mounted in an optional 19-inch cabinet with main unit.

  • High accuracy dilution

Reliable diluter developed by HORIBA Group
  Patent number: 7201071(US)

  • Dedicated particle number counting

Fully integrated system for stand-alone operation with the comprehensive
data logging functions. Also available for operation with host CPU control
using the AK-LAN host interface.

ModelsMEXA-2000SPCSMEXA-2100SPCSMEXA-2200SPCSMEXA-2300SPCS
Complying Regulations*1GTR No.15,
Amendment 6
Euro 6, Euro VI,
Stage V (NRMM),
China 6, China VI,
Bharat Stage VI (LDV/HDV)
-GTR No.15,
Amendment 6
Euro 6, Euro VI,
Stage V (NRMM),
China 6, China VI,
Bharat Stage VI (LDV/HDV)
-*2
Measuring principleLaser scattering condensation particle counting (CPC)
Lower particle size limitCounting efficiency of 23 nm particles: 50 % ±12 %, Counting efficiency of 41 nm particles: >90 %
Measuring components and rangeNumber concentration of solid particles; 0 – 10000 up to 0 – 50000 particles/cm3 (after internal dilution) *3
Sample handling temperature52 °C or less (Dilute sampling)Maximum permissive temperature
(Direct sampling) 350 °C *4
52 °C or less (Dilute sampling)Maximum permissive temperature
(Direct sampling) 350 °C *4 
Diluted sample temperaturePrimary diluter (PND1):
191 °C ± 10 °C
Evaporation tube (ET):
350 °C ± 10 °C
Secondary diluter (PND2):
< 35 °C (at inlet of CPC)
Pre-classifier: 47 °C ± 5 °C
Primary diluter (PND1):
191 °C ± 10 °C
Evaporation tube (ET):
350 °C ± 10 °C
Secondary diluter (PND2):
< 35 °C (at inlet of CPC)
Primary diluter (PND1):
191 °C ± 10 °C
Evaporation tube (ET):
350 °C ± 10 °C
Secondary diluter (PND2):
< 35 °C (at inlet of CPC)
Pre-classifier: 47 °C ± 5 °C
Primary diluter (PND1):
191 °C ± 10 °C
Evaporation tube (ET):
350 °C ± 10 °C
Secondary diluter (PND2):
< 35 °C (at inlet of CPC)
Dilution factors in diluters Primary diluter (PND1):
10 to 200 *3
Secondary diluter (PND2): 15
Diluter in DSU: 10
Primary diluter (PND1):
10 to 200 *3
Secondary diluter (PND2): 15
Primary diluter (PND1):
10 to 200 *3
Secondary diluter (PND2): 15
Diluter in DSU: 10
Primary diluter (PND1):
10 to 200 *3
Secondary diluter (PND2): 15
PCRF0.95 < fr (30 nm) / fr (100 nm) < 1.3, 0.95 < fr (50 nm) / fr (100 nm) < 1.2
Volatile particle removal efficiency>99.0%, for C40 (30 nm of particle size, and 10000 particles/cm3 or more)
Accuracy of dilution factorWithin ± 10 % of nominal dilution factor setting (for VPR total dilution factor of 150 to 3000, gas based) *5
Operating environmentWithout CLU (standard): Ambient temperature: 5 °C to 30 °C, Ambient humidity: 80 % or less as relative humidity
With CLU (optional): Ambient temperature: 5 °C to 45 °C, Ambient humidity: 80 % or less as relative humidity
Power supply voltage and frequency200/220/230/240 V AC (±10 %, max. 250 V), 50/60Hz (±1.0 Hz), single phase (to be specified at ordering)
Power requirementsMain unit: Max. 2.3 kVA
Main unit and all optional units: Max. 4.5 kVA
Main unit: Max. 2.5 kVA
Main unit and all optional units: Max. 4.4 kVA
Main unit: Max. 2.4 kVA
Main unit and all optional units: Max. 4.3 kVA
Main unit: Max. 2.6 kVA
Main unit and all optional units: Max. 4.5 kVA
Dimensions (excluding any projections) /Mass  
Main unit
(without transfer tube, control unit and optional units)
434(W)×731(D)×637(H) mm
Approx. 115 kg
434(W)×845(D)×637(H) mm
Approx. 120 kg
434(W)×910(D)×637(H) mm
Approx. 140kg
434(W)×910(D)×637(H) mm
Approx. 145 kg
Optional units                                        CYU: Approx. 290(W)×146(D)× 236(H) mm *6 Approx. 4 kg
                                        SRU: Approx. 300(W)×550(D)× 450(H) mm Approx. 35 kg
                                        CLU: Approx. 570(W)×850(D)×1227(H) mm Approx. 80 kg (for CLU and optional cabinet)
                                        DFC: Approx. 464(W)×550(D)× 320(H) mm Approx. 38 kg
                                        LCU: Approx. 350(W)×690(D)× 670(H) mm Approx. 35 kg
                                        VGU: Approx. 550(W)×300(D)× 450(H) mm Approx. 20 kg 


*1: Please contact us for more information on the regulations that the products comply with.
*2: MEXA-2300SPCS can be used in the measurement method according to the regulation. For detailed information, please contact HORIBA.
*3: Dilution factor of the system should be determined so that the particle concentration after dilution fits into the measuring range.
*4: Allowable range of gas temperature at sample probe inlet depends on the sampling condition, because it is limited as the temperature of diluter in DSU (350 °C or less). For detailed information, please contact HORIBA.
*5: Accuracy of dilution factor check with span gas.
*6: The dimensions depend on customers.

Brake Dust Measurement
Brake Dust Measurement
A series of legislative measures has significantly reduced the amount of emissions that is being emitted by internal combustion engines of light and medium-duty vehicles.
Particle Measurement in the Sub-23nm Range
Particle Measurement in the Sub-23nm Range
Concerns exist that advances in modern engine technology may contribute to large portions of solid particles at sizes smaller than 23nm. The EU Joint Research Center has confirmed this concern in several investigations.

Informationsanfrage

Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten. * Diese Felder sind Pflichtfelder.

Related products

More CVS-ONE

Constant Volume Sampler

More EXFM-ONE

Ultrasonic Exhaust Flow Meter

More FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

More FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

More GIANT 6000 Series

Multi-Purpose Brake Dynamometers

More GIANT Evo

Brake Test Systems

More MDLT-ONE

Micro Dilution Tunnel

More MEDAS

Altitude Simulation

More MEXA-1170HCLD

Heated Type NOx Analyzer

More MEXA-1170HFID

Heated Type THC Analyzer

More MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

More MEXA-1300R

Motor Exhaust Gas Analyzer

More MEXA-584L

Automotive Emission Analyzer

More MEXA-730λ

Air-to-fuel Ratio Analyzer

More MEXA-ONE

Motor Exhaust Gas Analyzer

More MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

More MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

More OBS-ONE GS Unit

On-board Emissions Measurement System

More OBS-ONE IRLAM Unit

On-board Emissions Measurement System for NH3/N2O

More OBS-ONE PM unit

On-board Emissions Measurement System

More OBS-ONE PN Unit

On-board Emissions Measurement System

More OBS-ONE SPN10 Unit

On-board Emissions Measurement System for SPN10

More PFS-ONE

Particulate Filter Management System

More PTFM-1000V2

Pitot Tube Flow Meter

More PTFM-ONE-DT

Dual Pitot Tube Flow Meter

More PX-375

Continuous Particulate Monitor with X-ray Fluorescence

More STARS Brake

Test Automation System for Brake Testing

More VULCAN

Chassis Dynamometer

More VULCAN Evo

Chassis Dynamometer

More XploRA™ PLUS

Raman Spectrometer - Confocal Raman Microscope

More AP-370 Serie

Analysatoren zur Überwachung der Umgebungsluft

More APDA-371

Feinstaubmessgerät

More APDA-372

Feinstaubmessgerät

More AQMS

Überwachungsstation für die Umgebungsluftqualität

More MESA-50

X-Ray Fluorescence Analyzer

More MESA-50K

X-Ray Fluorescence Analyzer

More OBS-ONE PM unit

On-board Emissions Measurement System

More PX-375

Continuous Particulate Monitor with X-ray Fluorescence

More TFH-01/47

PTFE Filter/TFH membrane

More XGT-9000

X-ray Analytical Microscope (Micro-XRF)

More XGT-9000SL

X-ray Analytical Microscope Super Large Chamber Model

More OBS-ONE PN Unit

On-board Emissions Measurement System

More OBS-ONE SPN10 Unit

On-board Emissions Measurement System for SPN10

Corporate