Laser Spectroscopic Motor Exhaust Gas Analyzer
The MEXA-ONE-QL-NX is an analyzer for the direct, simultaneous real-time measurement of the four relevant nitrogen-containing exhaust gas components NO, NO2, N2O and NH3.
The analyzer combines a light source based on the new quantum cascade technology (efficient lasers in the mid-infrared spectral region) with a precisely adjusted dual path cell to measure low concentrations with maximum sensitivity. The detection limit complies with current European legal requirements.
Furthermore, the MEXA-ONE-QL-NX offers wide measuring ranges of up to 5000 ppm (for NO). By using extremely narrowband light sources and measuring under reduced pressure the cross-sensitivity to other exhaust gas components can be drastically minimized.
The complete measuring system - including filtration - is specifically developed for the measurement of NH3 and thus guarantees a very fast NH3 rise time (T10-T90) of less than 5 seconds.
The MEXA-ONE-QL-NX can be operated as a stand-alone analyzer or integrated into the MEXA-ONE software interface for user-friendly and simplified system operation.
Model | MEXA-ONE-QL-NX |
---|---|
Measuring principle | Quantum Cascade Laser Infrared (QCL-IR) Spectroscopy |
Measuring components | NO・NO2・N2O・NH3 |
Measuring range | NO: (low) 0-100 ppm (high) 0-5000 ppm NO2:(low) 0- 50 ppm (high) 0-2000 ppm N2O:(low) 0-100 ppm (high) 0-2000 ppm NH3:(low) 0- 50 ppm (high) 0-2000 ppm |
Zero noise(2σ) (σ:standard deviation) | NO :(low) < 0.4 ppm (high) < 20 ppm NO2:(low) < 0.2 ppm (high) < 8 ppm N2O:(low) < 0.4 ppm (high) < 20 ppm NH3:(low) < 0.2 ppm (high) < 8 ppm |
Sample line temperature | 113 ± 6ºC |
Response time ( t10-90) | NO, NO2, N2O: < 2 s NH3: < 5 s* |
Dimensions/mass | Main unit:440×660×877 (mm) Approx.: 120 kg (excluding protruding objects) |
Sampling rate | 10 Hz |
Flow rate | 8 L/min ± 1 L/min |
Inlet pressure | standard: - 5 kPa to +30 kPa (relative) optional: -5 kPa to + 200 kPa (relative) |
Span noise | < 2% full scale (FS) |
Zero/ span drift | < 1% FS/ 8 h |
Warm-up time | 2 h |
* determined with NH3 (50 ppm) supplied to the sample inlet at a flow rate of 8 L/min via a 0.3 m sample probe, a heated filter and a 6 m heated line.
Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten. * Diese Felder sind Pflichtfelder.
FTIR Exhaust Gas Analyzer Dilute Measurement Type
FTIR Exhaust Gas Analyzer Direct Measurement Type
Altitude Simulator
Altitude Simulation
Heated Type NOx Analyzer
Heated Type THC Analyzer
Motor Exhaust Gas Sulfur Analyzer
Motor Exhaust Gas Analyzer
Solid Particle Counting System
FTIR Motor Exhaust Gas Analyzer
On-board Emissions Measurement System
On-board Emissions Measurement System for NH3/N2O
On-board Emissions Measurement System
On-board Emissions Measurement System
On-board Emissions Measurement System for SPN10
Pitot Tube Flow Meter
Dual Pitot Tube Flow Meter
Chassis Dynamometer
Chassis Dynamometer
Analysatoren zur Überwachung der Umgebungsluft
Ambient Ammonium Monitor
Ambient Hydrogen Sulfide Monitor
Stack Gas Analysis System
FTIR Exhaust Gas Analyzer Dilute Measurement Type
FTIR Exhaust Gas Analyzer Direct Measurement Type
Stack Gas Analyzer
Heated Type NOx Analyzer
Heated Type THC Analyzer
Motor Exhaust Gas Sulfur Analyzer
Motor Exhaust Gas Analyzer
FTIR Motor Exhaust Gas Analyzer
On-board Emissions Measurement System
On-board Emissions Measurement System for NH3/N2O
Portable Gas Analyzer
Multi-Component Gas Analyzer