Cathodoluminescence F-CLUE

Compact Hyperspectral CL

The F-CLUE is the optical fiber coupled solution offering a flexible interface for Cathodoluminescence Imaging and Spectroscopy analysis.

Thanks to its rugged ultra-compact footprint and deported spectroscopy modules, it can be installed even on very busy microscopes and/or in harsh industrial environments or extreme conditions (clean room, mobile laboratories…).

Like the whole CLUE series, its compact and fully retractable collection interface offers the possibility to upgrade CL on any commercial microscope without any restriction on performance.

The accurate video assisted micropositioning of the mirror permits to optimize collection efficiency and guarantee the best performance and reproducibility of your CL measurement.

Controlled by Labspec 6 Simply Powerful software suite, F-CLUE features advanced unique functionalities for both fast imaging and spectroscopy analysis (KIA spectral database, SWIFT, cosmic ray removal, peak fitting, particle finder, mosaic, multivariate analysis, advanced 3D display…)

Segment: Scientific
Division: Molecular and Microanalysis
Base product
Manufacturing Company: HORIBA France SAS

Flexible solution to fit any kind of environment, featuring:

•     Imaging and/or hyperspectral CL
•     Rugged optical fiber interface
•     Selection of ellipsoidal or parabolic retractable mirror to fit all sample types and applications
•     Powered by LabSpec 6TM Software
•    Fully motorized spectrometer
•    Optional RGB filters

Spectral Range

UV-VIS or VIS-NIR fiber dependent

Diamond turned collection mirror

ellipsoidal mirror
short & long working distances

200 mm retractable interface

Manual fine adjustment under vacuum

CL imaging detector

Standard: Panchromatic and monochromatic CL with ambient PMT
Options: Cooled PMT, IGA monochannel, photon counting PMT, time resolved PMT, RGB filters

CL spectrometer type

microHR (180mm) or iHR 320 (320 mm focal length), up to 3 grating turret, up to 2-entrance / 2 exit

Upgrade available

Upgrade from PL, MicOS systems

Electron beam control

CL-LINK for multiple acquisition processing (Analog, pulse mode, SE), Mapping linescan,
point measurement, Synchronization with spectroscopic detection, Control by external scan input of Electron Microscope

Software

Spectroscopy and imaging powered by LabSpec 6™

Remote Controller

Optional

Clue Accessories

Polarization, ND filter, camera, EMCCD etc

SEM Accessories

LN2, He cryo-stages, EBIC detector and many other accessories to complement our CLUE Series add-on detectors

Defect Evaluation of GaN Epitaxial Wafer by CL
Defect Evaluation of GaN Epitaxial Wafer by CL
The threading dislocation occurs easily in GaN crystal grown on sapphire substrates. It is said that this is caused by the large lattice mismatch of sapphire and GaN. The crystal may seem to be uniform in the SEM image, but the dark spot such as the threading dislocation can be observed when measuring the CL intensity image at the wavelength (362nm) which corresponds to the band edge emission.
Luminescent Defects in Synthetic CVD Diamond Films Localized by Cathodoluminescence Spectroscopy
Luminescent Defects in Synthetic CVD Diamond Films Localized by Cathodoluminescence Spectroscopy
The characterization of synthetic CVD diamond material by hyperspectral cathodoluminescence spectroscopy and imaging allows the detection and accurate location of the promising NV luminescent point defects for innovative solid-state quantum mechanical systems. In this work we performed CVD epitaxial growth on a pattern of micro-pillars etched on a diamond substrate. Cathodoluminescence (CL) analysis revealed that NV centres were successfully localized at the edges of the pillars.
The Evaluation of Phosphor for White LEDs by CL Image
The Evaluation of Phosphor for White LEDs by CL Image
Phosphor plays a key role to obtain white light as for blue LED + phosphor and near ultraviolet LED + phosphors. In order to improve high bright white LEDs, it is necessary that the whole phosphor particle emits light homogeneously. When measuring with CL the phosphor used as white LED, the area which does not emit light in phosphor particle can be observed. CL system is used for evaluation of non-luminescent area to improve luminescent efficiency and characteristics.
Cathodoluminescence F-CLUE
CategoryDocuments
Size 5.18 MB
FiletypePDF

REQUEST FOR INFORMATION

Do you have any questions or requests? Use this form to contact our specialists.

Related products

3D Surface and Volume Display
More3D Surface and Volume Display
3D confocal volume control and display
AFM-Raman - TERS Probes
MoreAFM-Raman - TERS Probes
Reliable, efficient TERS probes for NanoRaman imaging
APDA-372
MoreAPDA-372
Ambient Dust Monitor
APMC-370
MoreAPMC-370
Air Pollution Multigas Calibrator
Auto SE Accessories
MoreAuto SE Accessories
Customize your instrument
Auto Soft
MoreAuto Soft
Intuitive Auto-Soft Interface for the Auto SE and Smart SE
Batch Processing
MoreBatch Processing
High throughput data processing
CaptuR – Laser Trapping Solution - Raman Accessory
MoreCaptuR – Laser Trapping Solution - Raman Accessory
Raman Accessory for Life Science
Cathodoluminescence H-CLUE
MoreCathodoluminescence H-CLUE
Versatile Hyperspectral CL
Cathodoluminescence i-CLUE
MoreCathodoluminescence i-CLUE
Fast Imaging CL
Cathodoluminescence R-CLUE
MoreCathodoluminescence R-CLUE
Raman PL & CL
CC-55 Imaging Spectrometer
MoreCC-55 Imaging Spectrometer
Control unit PE-D20
MoreControl unit PE-D20
Conversion adapters CA series
MoreConversion adapters CA series
CP20 Series
MoreCP20 Series
OEM miniature spectrograph
Customize with VBS
MoreCustomize with VBS
Scripts and ActiveX
Customized reporting
MoreCustomized reporting
Create templates for fast data reports
Dedicated power sources PE Series
MoreDedicated power sources PE Series
DeltaPsi2 Software
MoreDeltaPsi2 Software
A Platform for HORIBA Scientific Ellipsometers
Detector - Hyperspectral camera and imaging sytems (HSI)
MoreDetector - Hyperspectral camera and imaging sytems (HSI)
Display unit DU series
MoreDisplay unit DU series
DuoScan™ Macro and Sub-Micron Raman Mapping
MoreDuoScan™ Macro and Sub-Micron Raman Mapping
Raman Accessory for fast imaging
Eco Web
MoreEco Web
Data Management and Reporting Software
EMIA-Step
MoreEMIA-Step
Carbon/Sulfur Analyzer
Environmental Raman Stages
MoreEnvironmental Raman Stages
Epifluorescence
MoreEpifluorescence
Cooled fluorescence imaging cameras
Ez suite
MoreEz suite
Powerful software suite for high-throughput label-free molecular interaction assays
EzSpec Software
MoreEzSpec Software
Fast Feed Back Auto Focus
MoreFast Feed Back Auto Focus
Raman Accessory for Imaging
Flat Correction
MoreFlat Correction
Unique fluorescence removal tool
GDOES Accessories
MoreGDOES Accessories
Accessories for samples with various shapes, sizes and properties
Gratings - OEM Diffraction Grating
MoreGratings - OEM Diffraction Grating
High Performance Detectors
MoreHigh Performance Detectors
ICP-OES
MoreICP-OES
Complete your ICP-OES Spectrometer for your specific needs
Image Analysis and Display
MoreImage Analysis and Display
Convert map data into chemical images
Instant Processing
MoreInstant Processing
On-the-fly custom data processing
IOX-370
MoreIOX-370
Datalogger IO-Expander
Labspec 6 Spectroscopy and imaging software
MoreLabspec 6 Spectroscopy and imaging software
LabSpec 6: Validated performance
MoreLabSpec 6: Validated performance
LabSpec 6 is a validated software
Mass Flow Checker MFT-20
MoreMass Flow Checker MFT-20
MESA-7220
MoreMESA-7220
Measurement of Sulfur and Chlorine in Petroleum Products
Microscope Objective UVI 74x
MoreMicroscope Objective UVI 74x
Mini CCT Plus
MoreMini CCT Plus
Mini Raman Spectrometer
Monitor unit PE-D10
MoreMonitor unit PE-D10
Motorized XY Mapping Stages
MoreMotorized XY Mapping Stages
Multi-point Chemical Solution Monitor CS-100F4
MoreMulti-point Chemical Solution Monitor CS-100F4
Multivariate Analysis
MoreMultivariate Analysis
Data analysis for complex data sets
MultiWell Module
MoreMultiWell Module
NavMap Application
MoreNavMap Application
Lets you navigate easily through your image
NavSharp
MoreNavSharp
Navigate your sharp image in real-time
OEM Raman Lasers with wavelength-stabilization
MoreOEM Raman Lasers with wavelength-stabilization
Only available for volume OEM purchase, minimum order quantity 50 units.
OEM Raman Miniature Probes
MoreOEM Raman Miniature Probes
OEM Miniature Raman Systems and Components
OneCheck System Validation
MoreOneCheck System Validation
Alignment and calibration tools
OneClick
MoreOneClick
Fast and easy Raman acquisition
OZGU-370SE
MoreOZGU-370SE
Ozone Transferstandard
Particle Finder
MoreParticle Finder
PE-S7
MorePE-S7
PP-TOFMS Software
MorePP-TOFMS Software
Egonomic software for data acquisition, data treatment and technical support
ProtectionPlus Module
MoreProtectionPlus Module
Regulatory compliance and data integrity
PSA300
MorePSA300
Static Image Analysis System Particle Size
Cathodoluminescence H-CLUE
MoreCathodoluminescence H-CLUE
Versatile Hyperspectral CL
Cathodoluminescence i-CLUE
MoreCathodoluminescence i-CLUE
Fast Imaging CL
Cathodoluminescence R-CLUE
MoreCathodoluminescence R-CLUE
Raman PL & CL