Industrial pH meter HP-480

Industrial pH meter HP-480

The HP-480 covers a wide range of usages such as monitoring industrial effluent, monitoring manufacturing processes in various industrial areas and quality inspections, as well as for fisheries industry and aquaculture industry.

 

Segment: Process And Environment
Division: Process Water
Base product
Manufacturing Company: HORIBA Advanced Techno Co. Ltd.

 

  • Easy pH correction
    After immersing the pH poles in the standard fluid, simply follow the instructions displayed and press the ENT key.
    The automatic correction process is plain and simple.
  • Automatic diagnosis function for faults in electrode properties
    If there is an asymmetry potential, sensitivity or response speed in correction, the HP-480 automatically determines whether there is a fault in the pH electrodes, and displays an error message.
  • Compatible with five types of temperature compensation element
    Five types of temperature compensation element are supported: 500 Ω, 6.8 kΩ, 1 kΩ, 10 kΩ and 350 Ω.
  • A line-up of lead-free pH electrodes
    Uses lead-free glass. In addition, almost all sections of the pH electrodes, including lead wires and soldered junctions are lead-free.
  • Uses lead-free solder
    To reduce the burden on the environment, lead-free solder has been used to mount the components on the printed circuit board.

 

 

Product name

Industrial pH meter

Model

HP-480

Measuring range

pH 0 to 14: resolution of 0.01 pH
Temperature 0 to 100: resolution of 1°C (selectable)

Transmission output

4 mA to 20 mA DC, input / output isolated type
Maximum load resistance 900 Ω
Transmission output range: freely selectable within the measurement range

Repeatability

Within ±0.05 pH of the full scale (by equivalent input)

Linearity

Within ±0.05 pH of the full scale (by equivalent input)

Contact output

Output: 2 points
Alarm contact output (R1 and R2)
Contact type: relay contact, SPDT (1c)
Contact capacity: 240 VAC, 3 A and 30 VDC, 3 A (resistance load)
Contact function: selectable from upper / lower limit operation (ON / OFF control), alarm, and maintenance.

Calibration function

Two-point automatic calibration or manual calibration
Temperature calibration (one point)

Transmission output
hold function

 
  • Just before hold
  • Optional value hold
  • Continuous

Selectable from the above (However, only the just before hold is available in the maintenance mode.)

Self-diagnosis function

 
  • Calibration failure
  • Electrode self-check
  • Outside of the measuring range
  • Transducer error
 

Temperature
compensation element

Selectable from compensation ON (500 Ω (25°C), 6.8 kΩ (25°C), 350 Ω (25°C), 1 kΩ (0°C) or 10 kΩ (25°C)) and compensation OFF

Power supply

Rated voltage 100 to 240 VAC, 50/60 Hz, 10 VA (max.)

Structure

Indoor-use panel installation type
Panel: IP65 drop-proof structure

Protective structure

Panel: IP65 (IEC60529, JIS C0920)

Conforming standards

CE Marking
FCC Rule

External dimensions

48 (W) x 96 (H) x 115 (D) mm
Case depth: approx. 105 mm

Mass

Approx. 400 g

Waste Water Treatment and Disposal in Water Waste Management and Remediation Services
Waste Water Treatment and Disposal in Water Waste Management and Remediation Services

REQUEST FOR INFORMATION

Do you have any questions or requests? Use this form to contact our specialists.

Product Accessories

More6155 Series/6855 Series
Industrial Gel-filled pH/ORP Electrode