IT-480 series

High-Accuracy Infrared Thermometers [Stationary type]

Industry Leading* High Accuracy Thermometer

IT-480 series are compact, stationary type infrared thermometers with industry-leading* accuracy, which enables measurement without damaging the object.
These infrared thermometers are suitable for industrial applications such as temperature control of various product lines, devices and plants.
Also, by connecting USB to a personal computer (PC) equipped with Windows®, IT-480 series can be widely used for laboratory and R&D.
IT-480 Data Acquisition Software is required to connect PC to IT-480 series. This software can be downloaded free of cost.

 

*Resuts of 2018 in-house study

Division: Thermometer
Manufacturing Company: HORIBA, Ltd.

<Features>

  • High precision: Industry’s highest precision standard thermometer.
  • Traceability: Adjustment/Calibration according to the Japanese national standards.
  • Product conformity according to various country standards: CE, WEEE/RoHs, FCC, KC, laser pointer related (PSC, FDA)
  • Application software: Provided for free of cost
     

▶ Non-contact, non-destructive system allows measurement without damaging the products whether stationary, rotating or moving.
▶ Industry-leading high accuracy and real-time response.
▶ A wide measurement range. -50°C to 1000°C (IT-480F/480P)
▶ Compact, lightweight design allows installation in various devices and production lines.
▶ Allows flexible use. For R&D, experiments, confirmation before the installation of IT-480 etc.
    Easy to set and use anywhere.
    ・USB bus powered type, which requires no external power supply.
    ・Available to mount on the camera tripods.
    Use of Data Acquisition Software (downloadable free of cost)
    ・Up to 8 units of IT-480 can be connected to a Windows® PC by USB cable.
    ・Easy to setup by Windows® PC, and collects temperature data

<Software Screen example-Device Setup>

<Software screen example-Data acquisition>

<Software>

IT-480 Data Acquisition Software "IT-480 Data Acquisition" is software dedicated to the radiation thermometer IT-480 series. Check/Change of Various settings, operation check and data acquisition are available for IT-480 connected to a personal computer via USB with "IT-480 Data Acquisition".
This IT-480 Data Acquisition software is freely downloadable.
Many other items, other than this software are also downloadable.

*To use IT-480 series without this software current output: 4 mA to 20 mA is also available.

Software requirements

• This software functions on PC or tablets installed with either the 32-bit or 64-bit version of Windows 7, Windows 8, Windows 8.1, and Windows 10.
• At least 1 GB of hard disk space is required to install this software.
• A screen resolution of at least 1280 dots X 800 dots (100% scaling ratio) is recommended.

Function

This software can be used to execute the following functions:
• Checking and changing settings
• Auto emissivity setting
• Current output test
• Measurement data collection (maximum of 8 units can be connected)
General-purpose communication software can also be used.

Downloadable items:

  • Instruction Manual for the IT-480
  • Data Acquisition Software "IT - 480 Data Acquisition"
    • 32 bit.zip
    • 64 bit.zip
    • User Manual for the IT-480 Data Acquisition
  • Virtual COM port driver for IT-480
    • driver.zip

    Serial communication with IT-480 is available with communication software such as "Tera Term" or a program created by a customer by installing the virtual COM port driver for IT-480 on the personal computer.
    Check/Change of Various settings and measurement value acquisition for IT-480 are available with serial communication.
    When only IT - 480 data collection software "IT - 480 Data Acquisition" is used, Installation of the virtual COM port driver is not required.

    • Reference Manual for the IT-480 Virtual COM Port Driver

    This software works on personal computers or tablets equipped with Windows 7, Windows 8, Windows 8.1, Windows 10 (32 bit, 64 bit). Operation check is done at factory.
    It does not guarantee the operation on all devices.

    Download

■IT-480S, IT-480L

TypeMicro-spot typeSpot type
ModelIT-480SIT-480L
Spectral response8μm to14μm
Measured temperature range-50℃ to 500℃
OutputUSB (resolution = 0.1℃)
Current (4 mA to 20 mA, resolution =0.24μA, non-insulated)
Currnent output range-50℃ to 500℃ (factory setting 0℃ to 500℃)
Accuracy〔USB Output〕
Within ±(-8%rdg+1)℃[-50℃ to 0℃]
Within ±1℃[ 0℃ to 200℃]
Within ±0.5%rdg℃[200℃ to 500℃]
〔Current Output〕
Difference from USB data is within ±(0.1% output range )℃
RepeatabilityWithin 0.5℃
Response TimeCurrent output 0.14 s or less
(95% response, moving average count is 1.)
Measurement diameterφ3 mm/ distance 30 mmφ8 mm/ distance 100 mm
Temperature driftWithin ±0.5℃/℃[-50℃ to 0℃]
Within ±0.25℃/℃[0℃ to 500℃]
EmissivityFactory setting: 0.950
(Setting range is 0.100 to 1.999.)
Ambient temperature / humidityTemperature: 0°C to 55°C
Humidity: 35% to 85% (No condensation)
Power supplyUSB bus power /12 V DC to 24 V DC
Power consumption30 mA or less (at 24 V DC)
Material of the body caseAluminum
MassApprox. 95 g
(Body only. Excluding cable and metal brackets)
SightSetting gauge

■IT-480N, IT-480W, IT-480F, IT-480P

TypeGeneral purpose typeNarrow view type
ModelIT-480N / IT-480W*1IT-480F / IT-480P*1
Spectral response8μm to 14μm
Measured temperature range-50℃ to 500℃-50℃ to 1000℃
OutputUSB (resolution = 0.1℃)
 Current (4 mA to 20 mA, resolution =0.24μA, non-insulated)
Currnent output range-50℃ to 500℃ (factory setting 0℃ to 500℃)-50℃ to 1000℃ (factory setting 0℃ to 500℃)
Accuracy〔USB Output〕
Within ±(-8%rdg+1)℃
 [-50℃ to 0℃]
Within ±1℃
 [ 0℃ to 200℃]
Within ±0.5%rdg℃
 [200℃ to 500℃]
〔Current Output〕
Difference from USB data is within ±(0.1% output range )℃
〔USB Output〕
Within ±(-8%rdg+1)℃
 [-50℃ to 0℃]
Within ±1℃
 [ 0℃ to 200℃]
Within ±0.5%rdg℃
 [200℃ to 1000℃]
〔Current Output〕
Difference from USB data is within ±(0.1% output range )℃
RepeatabilityWithin 0.5℃Within 1℃[ -50℃ to 0℃]
Within 0.5℃[ 0℃ to 500℃]
Within 1℃[ 500℃ to 1000℃]
Response TimeCurrent output 0.14 s or less
(95% response, moving average count is 1.)
Measurement diameterφ72 mm/ distance 1000 mmφ35 mm/ distance 1000 mm
Temperature driftWithin ±0.5℃/℃
 [-50℃ to 0℃]
Within ±0.25℃/℃
 [0℃ to 500℃]
Within ±0.5℃/℃
 [-50℃ to 0℃]
Within ±0.25℃/℃
 [0℃ to 500℃]
Within ±0.5℃/℃
 [500℃ to 1000℃]
EmissivityFactory setting: 0.950
(Setting range is 0.100 to 1.999.)
Ambient temperature / humidityTemperature: 0°C to 55°C
Humidity: 35% to 85% (No condensation)
Power supplyUSB bus power / 12 V DC to 24 V DC
Power consumption30 mA or less (at 24 V DC, laser: OFF)
40 mA or less (at 24 V DC, laser: ON)
Material of the body caseAluminum
MassApprox. 95 g
(Body only. Excluding cable and metal brackets)
Approx. 115 g
(Body only. Excluding cable and metal brackets)
SightLaser (Class 1)*1

*1) IT-480W and IT-480P are not equipped with the laser pointer

Request for Information

Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

Related products

IT-470F-H
More IT-470F-H

High-Accuracy Infrared Thermometer [Built-in type]

IT-545 Series
More IT-545 Series

High-Accuracy Infrared Thermometers [Handheld type]

CS-600F
More CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
More CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
More CS-900

Non-Contact Chemical Concentration Monitor

FES-310L
More FES-310L

Sanitary Conductivity Sensor (Flow Through type)

FS-01FC-SL Series
More FS-01FC-SL Series

Sanitary Conductivity Sensor (Flow Through type) for Low Concentrations

HC-200F (Four-Wire Analyzer)
More HC-200F (Four-Wire Analyzer)

Field-installation Type Simplified Fluoride Ion Concentration Meter(Four-Wire Transmission)

HC-200NH
More HC-200NH

Field-installation Type Ammonia Nitrogen Meter(Four-Wire Transmission)

HC-300F
More HC-300F

Field-installation Type Simplified Fluoride Ion Concentration Meter

HD-200
More HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-200FL
More HD-200FL

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Optical Type)

HD-300
More HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-480
More HD-480

Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HE-200C
More HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-200H (Four-Wire Analyzer)
More HE-200H (Four-Wire Analyzer)

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)

HE-200R
More HE-200R

Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)

HE-300C
More HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
More HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
More HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
More HE-480H

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480R
More HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HE-480R(W)
More HE-480R(W)

Industrial resistivity meter

HE-960CA
More HE-960CA

Citric Acid Monitor

HE-960CW
More HE-960CW

Panel-mount Type Conductivity Meter (Four-Wire Transmission, 2-channel)

HE-960H-TM
More HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
More HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
More HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
More HE-960HI

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Wide Range)

HE-960LC
More HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
More HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity meter

HE-960R-GC(W)
More HE-960R-GC(W)

Carbon Sensor Resistivity Meter