HORIBA
  • Products
    • By Segment
      • Automotive
      • Medical
      • Process and Environmental
      • Semiconductor
      • Scientific
    • All Products (A-Z)
    • By Industry
      • Arts, Entertainment and Recreation
        • Art Conservation
        • Museums, Historical Sites and Similar Institutions
      • Education, R&D and Government Institutions
        • Universities
        • Research and Testing Laboratories
      • Energy and Environment
        • Battery
        • Coal and Consumable Fuels
        • Electric Utilities
        • Energy Fuel Oil
        • Environmental Countermeasures
        • Oil and Gas
        • Petroleum and Coal Products Manufacturing
      • Food and Beverage
        • Beverages
        • Food
        • Cosmetics
      • Health Care
        • Biotechnology
        • HORIBA In Vitro Diagnostic solutions for human health care
        • Life Sciences
        • Pharmaceuticals and Medicine Manufacturing
      • Industrials
        • Building Products
        • Commercial and Professional Services
        • Electrical Equipment
        • Machinery
      • Information Technology
        • Semiconductor Manufacturing Process
      • Materials
        • Chemicals
        • Chemical Manufacturing
        • Containers and Packaging
        • Nonferrous Metals
        • Nonmetallic Minerals
        • Paper, Forest Products and Manufacturing
        • Plastics and Rubber
        • Primary Metals
      • Mobility and Transportation
        • Automobiles and Components
        • Automotive Manufacturing
        • Other Transportation Equipment Manufacturing
      • Waste Management
        • Solid Waste Management and Remediation Services
        • Water Waste Management and Remediation Services
      • Water
        • Desalination
        • Drinking Water Utilities
        • High Purity Water
        • Other Industry Water
        • Water Reuse
    • By Technique
      • Atomic Spectroscopy
        • Energy Dispersive X-ray Fluorescence (ED-XRF)
        • Glow Discharge Optical Emission Spectrometry (GD-OES)
        • Inductively Coupled Plasma - Optical Emission Spectroscopy (ICP-OES)
        • Inorganic Elemental Analysis
        • Beta-ray Absorption Analyzer
      • Electrochemistry
        • Potentiometry based on Ion-Selective Electrode (ISE)
      • Life Science Techniques
        • Label-free Detection / Surface Plasmon Resonance Imaging (SPRi)
      • Mass Spectrometry
        • Plasma Profiling Time-Of-Flight Mass Spectrometry (PP-TOFMS)
        • Quadrupole Mass Spectrometry
      • Material Characterization
        • Colorimetry
        • Condensation Particle Counter (CPC)
        • Dynamic Light Scattering (DLS) Particle Size Distribution Analysis
        • Magneto-pneumatic Analysis
        • Mechanical Flowmetry
        • Pressure-based Mass Flowmetry
        • Spectroscopic Ellipsometry
        • Static Light Scattering (SLS) / Laser Diffraction Particle Size Distribution Analysis
        • Fluid Measurement and Control
      • Molecular Spectroscopy
        • Absorption and Transmission Spectroscopy (UV, Visible, NIR)
        • Cathodoluminescence (CL, CLUE)
        • Chemiluminescence
        • Fluorescence Spectroscopy
        • Fourier-Transform Infrared Spectroscopy (FTIR)
        • Non-Dispersive Infrared Spectroscopy (NDIR)
        • Non-Dispersive Ultra Violet Spectroscopy (NDUV)
        • Photoluminescence (PL) & Electroluminescence (EL)
        • Quantum Cascade Laser (QCL) Spectroscopy
        • Raman Imaging and Spectroscopy
        • Vacuum Ultra Violet Spectroscopy
      • Radioactivity
        • Crystal Scintillation
      • Surface Science Techniques
        • Plasma Profiling Time-Of-Flight Mass Spectrometry (PP-TOFMS)
        • AFM-Raman (co-localized measurements & TERS)
  • Applications
    • Arts, Entertainment and Recreation
      • Art Conservation
      • Museums, Historical Sites and Similar Institutions
    • Education, R&D and Government Institutions
      • Universities
      • Research and Testing Laboratories
    • Energy and Environment
      • Coal and Consumable Fuels
      • Electric Utilities
      • Energy Fuel Oil
        • Wear metals and additive Elements Analysis.
      • Environmental Countermeasures
      • Petroleum and Coal Products Manufacturing
        • Petrochemicals
      • Photovoltaics
      • Oil and Gas
      • RoHS and ELV
    • Food and Beverage
      • Agriculture & Crop Science
      • Research & Development
      • Beverages
      • Food
      • Food & Beverage Manufacturing
    • Health Care
      • Biochemistry
      • Biotechnology
        • High Throughput Screening of Affimer Proteins using SPRi Label-Free Technology
        • Analytical Chemistry
      • Human Health Care
      • Life Sciences
        • Cell Biology
        • Blood Testing
        • Proteomics
        • Microbiology
        • Structural Biology
        • Genomics
        • Bioengineering
        • Nanoscience
        • Personal Care
      • Pharmaceuticals and Medicine Manufacturing
        • Cosmetics
        • Drug Discovery and Development
        • Drug Delivery
        • Counterfeit
        • Quality Assurance
        • Vacuum Monitoring in Dryer Equipment for Freeze Dry in Pharmaceuticals and Medicine Manufacturing
        • Bioprocessing
        • Analytical Chemistry
    • Industrials
      • Battery
      • Commercial and Professional Services
        • Gas mass flow control and measurement for reference value of PM2.5 measurement
      • Construction & Engineering
      • Electrical Equipment
      • Machinery
    • Information Technology
      • Semiconductors
        • 2D Materials
        • Graphene
        • Photovoltaics
        • Determination of Perovskite Optical Constants
        • Display Technologies
        • Data Storage
        • Nanomaterials
      • Semiconductor Manufacturing Process
      • Technology Hardware and Equipment
    • Materials
      • Ceramics
      • Chemicals
        • Fertilizers, phyo-sanitary
        • Polymers & Plastics
        • Analytical Chemistry
      • Chemical Manufacturing
      • Construction Materials
      • Containers and Packaging
        • Quality control in the aluminium packaging industry
      • Metal Powder
      • Nonferrous Metals
      • Nonmetallic Minerals
        • Glass
        • Coatings
      • Paper, Forest Products and Manufacturing
      • Plastics and Rubber
      • Primary Metals
      • Material Research
        • Corrosion
        • 2D Materials
        • Quantum Dots
        • Carbon based Materials - Graphene
        • Nanomaterials
      • Photovoltaics
      • Forensics
      • Metal and Mining
        • Gemstones
    • Mobility and Transportation
      • Automotive Manufacturing
      • Engine, Turbine and Power Transmission Equipment Manufacturing
      • Real Driving Emissions
      • RDE Plus
    • Waste Management
      • Solid Waste Management and Remediation Services
      • Water Waste Management and Remediation Services
        • Repeatability of Traces and Major Elements in Water
        • Very Rapid Analysis of Supply Water, Sludge From Purification Station and Animal Food
        • Waste Water and Soil Analysis
        • Waste Water Treatment and Disposal
    • Water
      • Drinking Water Utilities
      • Water Reuse
        • Water Testing
      • General Water Measurement
  • Technology
    • Measurement and Control Techniques
      • Electrochemistry
        • The Story of pH
        • The Basis of pH
        • Measurement of pH
        • The Story of Ion
        • The Basis of Ion
        • Measurement of Ion
        • The Story of ORP
        • The Basis of ORP
        • Measurement of ORP
        • The Story of Conductivity
        • The Basis of Conductivity
        • Measurement of Conductivity
        • The Story of Salt
        • The Story of Dissolved Oxygen
        • The Basis of DO Measurement
        • LAQUA Electrode Technology
      • Elemental Analysis
        • X-ray Fluorescence Spectroscopy (XRF)
        • Glow Discharge Optical Emission Spectroscopy
        • Inductively Coupled Plasma - Optical Emission Spectroscopy (ICP-OES)
        • Carbon/Sulfur & Oxygen/Nitrogen/Hydrogen Analysis
      • Health Care
        • Multi Distribution Sampling System (MDSS)
        • Reticulocytes Analysis
        • CBC + CRP
        • Slide Production
        • Automatic Rerun
        • Absorbance
        • Fluorescence
        • Flow cytometry
        • Impedance / Resistivity
        • Sedimentation
        • Spectrophotometry
        • Potentiometry
        • INR screening
        • Clotting
        • Turbidimetric
        • Chromogenic
      • Light Scattering
        • Dynamic Light Scattering (DLS) Particle Size Distribution Analysis
        • Molecular Weight
        • Raman Scattering
        • Static Light Scattering (SLS) / Laser Diffraction Particle Size Distribution Analysis
        • Zeta Potential
      • Fluid Control
        • Thermal Mass Flowmetry
      • Mass Spectrometry
        • Quadrupole Mass Spectrometry
      • Microscopy and Imaging
        • AFM-Raman
        • Atomic Force Microscopy [AFM]
        • Cathodoluminescence
        • Image Analysis of Particles
        • Micro-X-ray Fluorescence
      • Physisorption
        • Surface Area
      • Spectroscopy
        • Cathodoluminescence Spectroscopy
        • AFM-Raman
        • Detectors
        • 50 years of Diffraction Gratings
        • Diffraction Gratings Ruled and Holographic
        • Fluorescence Spectroscopy
        • Raman Spectroscopy
        • Spectrometers, Monochromators and Spectrographs
        • Spectroscopic Ellipsometry
        • Vacuum Ultra Violet Spectroscopy
        • X-ray Fluorescence
      • Surface Plasmon Resonance
        • Surface Plasmon Resonance Imaging (SPRi)
  • Service
    • Analysis Services
      • Analysis Centers and Services
      • EMC Analysis Service
    • Calibration and Certification
      • Calibration Centers
    • Customer Support
      • HORIBA Medical Documentation Database
      • Medical Customer Support
      • On-Site Support
      • Software Upgrades
      • STARS Helpdesk
    • Maintenance
      • Dynamometer and Other Overhaul Services
      • Periodic Maintenance
    • Spare Parts and Consumables
    • Testing and Consulting
      • Testing Centers
    • Training
      • Product Training
        • Scientific Product Training
        • Automotive Product Training
        • Medical Product Training
      • Technology Training
        • Raman Training
        • Glow Discharge Training
        • Fluorescence Training
        • Ellipsometry Training
        • SPRi Training
        • Inductively Coupled Plasma Training
        • Inductively Coupled Plasma Training (USA)
        • PSA Training
        • Carbon, Sulfur, Oxygen, Nitrogen and Hydrogen Analyzers Training (USA)
        • Online-OnSite Training
  • Company
    • About HORIBA
      • Message
      • Company Profile
        • Board of Directors
        • Corporate Officers
      • Culture
        • Corporate Philosophy
      • History
        • 1945–1960s
        • 1970s
        • 1980s
        • 1990s
        • 2000s
        • 2010s
      • Technical Journal "Readout"
        • Masao Horiba Awards Research Articles
        • Readout No. E54 - Microplastics and Nanoplastics: Analysis and Method Development
        • Readout No. E53 - 2019 Masao Horiba Awards - Advanced Analytical and Measurement Technologies for Efficient Control System to Maximize the Performance of Electric Power and Batteries Usage
        • Readout No. E52 - Green Innovation for Marine Shipping Industry
        • Readout No. E51 - 2018 Masao Horiba Awards Advanced analytical and measurement technologies in semiconductor manufacturing processes
        • Readout No. E50 - Low-Carbon Society and Environmental Improvement
        • Readout No. E49 - Photonic Instrumentation in Life Science
        • Readout No. E48 - Water Measurement Experts
        • Readout No. E47 - Application for Semiconductor Manufacturing Process
        • Readout No. E46 - New Development for Automotive Test Systems
        • Readout No. E45 - Application Technology in Analysis
        • Readout No. E44 - Contribution of Diagnostics to Total Medical Care/Healthcare
        • Readout No. E43 - Watching the Environmental and Society with Measurements
        • Readout No. E42 - More Efficient Testing on Automotive Development, Improving the Accuracy of Fuel Consumption Measurement
        • Readout No. E41 - Application
        • Readout No. E40 - Application
        • Readout No. E18 - EUROPE
        • Readout No. E17 - AMERICA
        • Readout No. E16 - Chinese (Asia)
        • Readout No. E15 - Technologies for HORIBA STEC
        • Readout No. E14 - Masao HORIBA Awards"Measurement of Bioparticles" and "Measurement of Internal Combustion"
        • Readout No. E13 - Technologies for Automotive Testing
        • Readout No. E12 - Masao Horiba Awards "X-ray Analysis Technology"
        • Readout No. E11 - The Second Masao Horiba Awards
        • Readout No. E10 - Environmental Analysis Technologies for the Management of Global Environment and the Development of Industry
        • Readout No. E09 - The First Dr.Masao Horiba's Award and the 50th Anniversary Products
        • Readout No. E08 - Products and Technologies of HORIBA ABX
        • Readout No. E07 - Products and Technologies of Jobin Yvon HORIBA Group
        • Readout No. E06 - 50th Anniversary of HORIBA, Ltd. Products and Technology of HORIBA Group
        • Readout No. E05 - Semiconductor Instruments
        • Readout No. E04 - Hematology Instruments
        • Readout No. E03 - Paticulate Matter
        • Readout No. E02 - The Technolgy Alliance for X-ray Analysis
        • Readout No. E01 - the Analysis of the Global Environment
      • Virtual Patent Marking
    • Events
    • Career
    • Investor Relations
      • Home
      • Investor Relations News
      • Management Policies
        • Message from the CEO
        • Mid-Long Term Management Plan
        • Corporate Governance
        • Corporate Culture "Joy and Fun"
        • Corporate Philosophy
      • IR Library
        • Financial Statements
        • Presentation Materials
        • HORIBA Report
        • Financial Information
      • Stock Information
        • Basic Stock Information
      • Investor Relations Contact
      • Other IR Information
        • Investor Relations Calendar
        • Disclaimer
    • News
    • Social Responsibility
      • Home
      • Message
      • HORIBA's CSR
        • CSR Policy, CSR Promotion System
        • UN Global Compact
        • HORIBA and the SDGs
      • Environment
        • Policy
        • Environmental Activities
        • Eco-Friendly Products
        • Actions for RoHS Directive, REACH Regulation and GHS Regulations
      • Social
        • Home
        • Integrated Management System
        • Quality
        • Occupational safety and health
        • Promotion of Diversity
        • Material Procurement
        • Social Activities
      • Governance
        • Corporate Governance
        • Code of Ethics
        • Internal Controls
        • Compliance Promotion Systems
        • Risk Management
      • HORIBA Special Contents
      • Library
      • HORIBA Group Social Media
        • Social Media Registered Accounts
        • HORIBA Group Social Media Policy
        • HORIBA Group Terms of Use for Social Media
      • Integrated Report
    • Group Companies
      • Americas
        • Brazil
        • Canada
        • United States
      • Asia
        • China
        • India
        • Indonesia
        • Japan
        • Korea
        • Philippines
        • Singapore
        • Taiwan
        • Thailand
        • Vietnam
      • Europe
        • Austria
        • Belgium
        • Czech Republic
        • France
        • Germany
        • Italy
        • Netherlands
        • Poland
        • Portugal
        • Romania
        • Russia
        • Spain
        • Sweden
        • Turkey
        • United Kingdom
  • Contact
    • Contact Form
    • Worldwide Locations
Glow Discharge Optical Emission Spectroscopy (GD-OES) open open
  • Basic Concepts
  • Sample Measurement with GDOES
  • Sample Test and Analysis
  • Comparison with Other Techniques: Surface Analysis
  • Comparison with Other Techniques: Bulk Analysis
  • Instrument Introduction
  • Benefits and Features of Pulsed RF GDOES
  • Join the GD Community
  • Bibliography
  • HORIBA
    • Products
    • Applications
    • Technology
    • Service
    • Company
    • Contact
    Technology
    • Measurement and Control Techniques
    Measurement and Control Techniques
    • Basic Concepts
    • Sample Measurement with GDOES
    • Sample Test and Analysis
    • Comparison with Other Techniques: Surface Analysis
    • Comparison with Other Techniques: Bulk Analysis
    • Instrument Introduction
    • Benefits and Features of Pulsed RF GDOES
    • Join the GD Community
    • Bibliography
    Sample Test and Analysis

Sample Test and Analysis

Can GDOES analyze small size samples?

Samples on small sample holder.

Fig 35: Samples on small sample holder.

The standard diameter is 4 mm corresponding to optimum compromise between crater shape and quantity of light collected. 2 mm, 7 mm and 1 mm anodes are also available. We have also done some 8 mm, 10 mm and 6 mm anodes on request. As long as the sample size is larger than the o-ring of the ceramic, we can directly analyze these samples.

Samples smaller than the o-ring can also be measured using an accessory – the small sample holder shown below. With this accessory, the vacuum seal is assured by the holder itself; the sample just needs to cover the anode diameter (5 mm for a 4 mm anode, 3 mm for a 2 mm anode etc). This accessory can also be used for rough surfaces.

Can hygroscopic or inflammable samples be measured by GDOES?

“Li bell” - a dedicated accessory for measuring hygroscopic or inflammable samples.

Fig 36: Li Bell

Hygroscopic or inflammable samples can also be done with care. A dedicated accessory (“Li bell”) was designed for the measurement of Li ion electrodes specifically. It allows transporting the samples to the instrument under an inert atmosphere and running the analysis without contact to air.

Can fragile samples and soft thin films be measured by Pulsed RF GDOES?

Craters obtained on a coated polymer foil after mounting on an Al substrate.

Fig 37: Craters obtained on a coated polymer foil after mounting on an Al substrate.

Fragile samples and soft thin films can be measured by Pulsed RF GDOES.

GD operation requires the use of a primary vacuum. Thin films or soft samples can be deformed due to the mechanical stress induced when vacuum to close the chamber, is applied on the samples. The analysis is then affected or even made impossible if the sample comes in contact with the anode, possibly creating a short circuit. So when analyzing this kind of sample, we need to glue the sample on a rigid substrate.

Appropriate gluing of such samples on a rigid support is the best way to maintain the quality of the analysis (control of the crater shape and preservation of the depth resolution).

Pulsed operation is most often needed for such fragile samples.

How to measure polymer films

The domain of polymer films is vast, applications are many and one could wonder why an elemental technique as GD would be of interest, thinking that Raman would be more appropriate.

Actually GD provides complementary information to other techniques that are useful for process development and failure analysis. Pulsed RF GDOES has for instance, measured paints on car bodies, plastic films to protect mobile phones, plastic DVD, or organic solar cells. Several papers have been published on these applications.

Pulsed operation is often needed to avoid thermal damage to the samples and preparation strategies may be required if thin films are to be measured.

The patented UFS might also be of interest in many cases as, for example, the analysis of protective films for mobile phones. In this example, 110 microns are sputtered in 11 minutes using the UFS, the presence of tracer elements permits identification of the layers and their function: Na, for instance is there for the capacitive contact – assuring that when typing on your film, information is sent to the phone glass window below.

How do you get information on layers buried below a thick polymer rapidly?

DVD featuring multi layers 100 nm thick below a 70 μm polymeric layer.

Fig 38: DVD featuring multi layers 100 nm thick below a 70 μm polymeric layer.

A very new patented development from HORIBA Scientific allows rapid (1-10 mn) sputtering of polymer layers, providing an optimum flat crater bottom when previously hours were needed. This is ideal to look at buried interfaces for painted car bodies, plastic DVDs, encapsulated solar cells, etc.

This new development keeps enlarging the range of applications for which the Pulsed RF GDOES benefits of speed and ease of use can be employed with great profit.

How can you easily remove oils, oxide films and other contaminants from surface for bulk analysis?

This applies to bulk analysis only where the purpose is to measure the core of the sample. The idea is to use preburning. Pre-burning the sample, also called pre-integration, simply means igniting the discharge, and waiting to reach a steady state before integrating the spectral intensities. Igniting the discharge also helps remove vapors, such as water, from the discharge cavity by destroying their molecular structure.

The result is an improved relative standard deviation (RSD) for calibration and bulk analysis measurements. Typical preintegration times are between 30s and 90s. Double preintegration and the use of different conditions could help to minimize this time or make it more efficient.

For obvious reasons, this pre-integration is not applied for surface and coating analysis, but plasma cleaning strategies (described later) can be applied.

How can you eliminate the influences of residual air in the source or adsorbed contaminants on the sample surface?

Principle of the GD process.

Fig 39: Principle of the GD process.

Even with clean Ar plasma gas, residual gas species (H, N, O, CO2 or H2O) are present from the sample surface (that can be porous, hydrated, etc.) or from leaks. They have a nonnegligible effect on the light intensities as they contribute to changes in the plasma. They should be minimized as much as possible.

“Plasma Cleaning” strategies offer elegant, practical ways to minimize such effects. They are based upon the following considerations: anode and sample surfaces, and gas atmosphere are sources of contamination (one more than the others, depending on the configuration) requiring the setting of a dedicated optimum strategy:

  • Use of higher purity Ar and longer flush time prior to analysis.
  • A silicon or alumina sample can be sputtered just prior to the analysis of a clean sample (without lamp cleaning in between). This deposits a small protective film on the tip of the anode that contributes to clean anode walls.
  • A first measurement can be done and the sample then moved on the side without the lamp being in contact with air. The second measurement will be cleaner.
  • Finally, and this is unique to pulsed RF operation, it is possible to operate the RF source at ultra low power in pulsed mode without sputtering the material. This creates a soft plasma which has too low an energy for material sputtering, but is sufficient in combination with the gas flow to clean the surfaces prior to analysis. After a few minutes of such “surface cleaning,” the normal analysis can start.

The Plasma Cleaning has been described in a paper published in JAAS.

Fig 40: Left: without plasma cleaning (high C signals, instabilities on Fi), Right: same sample with plasma cleaning (low C signals, stable plasma from the start).

How to do a normal quantitative analysis with GDOES?

Multimatrices calibration for Cr.

Fig 41: Calibration without SR.

Calibration principles are simple, and based on the unique feature that in the GD plasma, the erosion and the excitation are physically, spatially separated and can be treated in first approximation as independent features.

Step by step procedures are available from HORIBA Scientific and presented during our user trainings.

The sputtering efficiency (SR or q depending on notations) is taken into account - this is expressed as the mass removed per unit of time. It is dependent on the sample (or the layer) and of the operating conditions. It is a material property, not an element property.

Multimatrices Calibration for Cr.

Fig 42: Calibration with SR.

The intensity of light for an element is proportional to the concentration of this element in the plasma, and this relates to the concentration in the sample by the simple q factor.

ciqM = kiIi

ci composition
qM sputtering rate
Ii intensity
ki constant

If the SR is taken into account, one can perform calibration mixing samples from different families.

During a measurement, at any time, all intensities are recorded so all (cc*q) values are calculated, and by summing these numbers (knowing that sum of cc is always 100% at any depth) both the SR and the cc are known at each depth.

So quantification simultaneously gives the concentrations and the mass removed at each time, hence the depth (by calculating densities). In this standard approach, depths are calculated, such as erosion rates. Of course with DiP, these values are measured and therefore the quantification becomes more accurate, as no approximation is made at any step.

What are Certified Reference Materials (CRMs)?

A CRM is by definition a Reference Material, accompanied by a certificate, one or more of whose property values are certified by a procedure which establishes its traceability to an accurate realization of the unit in which the property values are expressed, and for which each certified value is accompanied by an uncertainty at a stated level of confidence. CRMs are most often bulk samples, though some layered samples can be found.

For most GD applications, CRMs do not exist and so reference materials – often provided by the customers themselves – are to be used.

For such reference materials, homogeneity can be checked by GD itself, while composition is to be determined by other techniques.

Why do we need Reference Materials?

Sample analyzed.

Fig 43: Sample analyzed.

As with all comparative techniques, Pulsed RF GDOES requires calibration to provide concentrations vs. depth (named “QDP” Quantitative Depth Profile or “CDP” Compositional Depth Profile) from the measured Intensities vs Time (Qualitative Depth Profile).

Qualitative depth profile.

Fig 44: Qualitative depth profile.

With pulsed RF, all types of samples can be used for calibrations, and not only bulk metallic samples as at the origin of GD. Samples can now be bulk (conductive or non) or layered samples – conductive or non. Oxides can be mixed within the calibrations to provide data points for O, and polymer layers can be added when organic layers are of interest.

QDP (Quantitative Depth Profile).

Fig 45: QDP (Quantitative Depth Profile).

How do you do quantitative analysis of advanced materials and new materials with GDOES?

For some advanced materials and new materials, it is very hard to get adequate reference materials to do normal quantitative analysis. But HORIBA GDOES instruments are designed to perform quantification with only one sample representative of the material investigated. This is called the layer mode.

The layer mode is a very elegant and the most simple way to calibrate the instrument for a certain application. It only requires knowing one type sample, representative of the material of interest. In the case of PV cells for instance, the availability of one cell, well characterized in thickness and composition, is enough to calibrate the instrument for the application.

How to measure crater depth and erosion rates

The measurement is done by interferometry. A unique laser beam (from a laser diode) is split. The reference beam goes to the intact sample surface near the crater when the sensing beam is directed in the middle of the crater. The reflecting signals are collected and measured in real time providing erosion rates and depth.

GD source with reference hole for DIP implementation.

Fig 46: GD source with reference hole for DIP implementation.

Fig 47: DiP logo

How do you increase the measurement time during the analysis without stopping the source?

The Time Plus function allows increasing the measurement time during the analysis without stopping the source. It is especially useful in depth profiling when unknown samples are run and one realizes that the present timing is not sufficient, and that the source will stop before the last layer is reached. Time Plus is a standard feature of the HORIBA GD instruments.

How do you reduce the ingress of air inside the source?

Each time the sample is removed from the source, the source is exposed to air. The discharge cavity will therefore contain some air every time the sample is changed or moved to a new position, even if the source is flushed with argon during the positioning process, though a constant argon stream should reduce the ingress of air. To obtain a pure argon atmosphere inside the source, after placing the sample, the closed source cavity is first evacuated and then flushed with argon. An effect of flushing the cavity prior to analysis is to reduce the time for the plasma to become stable during the analysis.

How are GDOES test results interpreted?

Typical questions arise when people look at a GD profile for the first time, notably the qualitative analysis.

How do you compare the elements?

Sample is a fake 1 Euro coin.

Fig 48: Piece of Euro.

The following example is shown during our trainings. Sample is a fake 1 Euro coin.

The central part which should be pure Ni in a real Euro is here a coated material: Ni/Cu/Fe.

Different lines are measured with different detectors and have different sensitivity and after quantification, this issue disappears. GD is a comparative technique.

This is why you cannot easily compare elements from their relative intensities in a qualitative profile. After quantification, this issue disappears.

Diffusion or roughness?

Overlay of measurements to study a varying process.

Fig 49: Overlay of measurements to study a varying process.

The second question is how can it be assessed that there is diffusion within a layer? Diffusion and roughness will both lead to enlarged interfaces (also the crater shape, but this is easier to assess with a profilometer, and to correct using adequate conditions).

A single profile does not easily permit differentiation between the two phenomena.

But if one looks at a sample before and after annealing for instance, and overlay the two results, the diffusion can easily be derived.

For this question also comparing samples is the key to proper interpretation of a GD profile.

  • Products
    • By Products (A-Z)
    • Automotive
    • Medical
    • Process and Environment
    • Scientific
    • Semiconductor
  • Applications
    • Drinking Water Utilities
    • Automotive Manufacturing
    • Semiconductor Manufacturing Process
    • Research and Testing Laboratories
  • Technology
    • Glow Discharge Spectroscopy
    • Pressure-based Flowmetry
    • Quadrupole Mass Spectrometry
    • Raman Spectroscopy
  • Service
    • On-Site Support
    • Spare Parts and Consumables
  • Company
    • News
    • Events
    • Career
    • History
    • Corporate Culture
  • Contact
    • Contact Form
    • Worldwide Locations

Terms and Conditions Privacy Notice Cookies Imprint