TX-100

Tunable Laser Gas Analyzer

TX-100 is HORIBA’s in-situ laser-based HCl analyzer with a probe type optical system. The TX-100 is suitable for monitoring HCl concentrations in incineration plant flue gas streams and for the control of HCl removal processes.

Division: Combustion
Manufacturing Company: HORIBA, Ltd.

Probe type optical system

  • Both laser and receiver are installed at the same side of the stack

  • Just one flange installation is sufficient for the setup

  • Easy replacement to an existing analyzer with no additional work

  • The stabilized optical axis provides excellent performance

  • Continuous moisture correction function supports high accuracy measurement

 

HORIBA’s original calibration mechanism


TX-100 implements calibration without any disruption to the facility’s operations. The zero point can be checked automatically and the signals are kept in stable condition over long term
(US patent No. 8934101; China patent No. ZL201280039440.7; patent applied for Japan, Europe)

 

<Measurement> Zero point checking and measurement are conducted alternately

Zero point checking mode
Zero point checking is carried out while the prism is inserted into the optical path at fixed intervals.

 

Measurement mode
In measurement mode, the prism moves upward and leaves the optical path

 

<Calibration> Calibration is conducted after span gas is filled in the calibration cell
Gas calibration is completed leaving the probe attached in the stack. 

 

Data management for the TX-100 can be selected from various components; Analyzer’s display, HMI (Human Machine Interface) unit, or from PC-HMI software

Analysis unit display
Basic display to confirm and control information such as equipment status, gas status and comunication status. 

 

HMI unit (option)
A touch panel screen that can set and confirm concentration, transmittance, trend graph, maintenance info, alarm status, etc.

 

PC-HMI (software)
PC-HMI is a software that includes almost the same function as the software instaled in HMI unit.  Install this software in a PC or other devices to operate. Ethernet is available for data transmission between PC and TX-100.  
Free download available from our website. 

 

Related Industries
NameTunable Laser Gas Analyzer
ModelTX-100
Measurement targetHCl and H2O in process gas
Measurement componentHCl, or HCl and H2O simultaneous measurement
Measurement principle

Non Dispersive Infrared (NDIR)

Measurement typeProbe type
Laser classCLASS1(IEC60825-1: 2014)
Protection degreeIP65
Wetted materialsSUS316L、SUS304、BK7、FKM、PTFE、aluminum alloy
Tube connectionsRc1/8 (Tube of 8 mm O.D./6 mm I.D.)
External dimentions

Analyzer: Max: 358 (W) x 517 (D) x 453 (H) mm
Probe
Flange diameter (Max.):  Φ235 mm、 Length: 1500 mm
Probe diameter: Φ 89 mm

Weight

Analyzer: 19 kg
Probe: 20 kg

Flange specificationsJIS10K-100AFF、JIS5K-125AFF、ANSI 150 Lb 4BRF
Power supply voltageDC24V±10%
Power consumption90 W
DisplayLCD (128 × 64 dots), LED (3 units: Status display)
Display contentsGas concentration, transmission, process gas temperature, process gas pressure, system status, alarm information, system information (product serial no., output signal, IP address, optical path length, analyzer unit internal temperature)
CommunicationModbusTM/TCP
Analog input/output

Input:
Two channels (Process gas temperature, process gas pressure)
4 to 20 mA (isolated input)

Output:
Two channels (Process gas concentration*, transmission, process gas temperature, process gas pressure)
4 to 20 mA (isolated output) Max. load: 550 Ω

Digital input/output

Input:
One channel (External alarm) 
Non-voltage digital input (isolated input) 
Input open signal: 100 kΩ or more 
Input close signal: 200 Ω or less

Output:
Two channels (Warning/Calibration/Warm-up/Maintenance state/Fault)
Relay contact output (isolated output) Max. 24 V, 1 A at each terminal

*You can select either fixed value or real time HCl correction using H2O concentration.
-Modbus is a trademark of Schneider Electric Inc.
-Consult HORIBA if special probe length is required.

 

Performance

Measurement component

HCl, H2O

Measurement range (250℃、101.3kPa)

HCl: 0-50,100,200,300,400,500 ppm*1

H2O: 0-50 vol%

Measured optical path length2m
Repeatability

HCl: +/- 1.0% F.S.

H2O: +/- 2.0% F.S.

Linearity

HCl: +/- 1.0% F.S.

H2O: +/- 2.0% F.S.

Zero drift

+/- 2.0% F.S. / 6 months

Span drift+/- 2.0% F.S. / 6 months
Data update cycleApprox. 2sec
Recommended Calibration cycle6 months
Calibration methodHCl: Manual calibration using gas cell
H2O: Factory calibration*2
Interference

+/- 2.0% F.S.
Gas conditions (at standard process gas condition range)

Warm-up time3hours

*1: Select a measurement range.
*2: You can adjust the H2O indicated value to the manual analysis value. Consult HORIBA for more details. 

 

 

Usage Conditions

Ambient temperature-20 ~ 55°C (no direct sun rays, radiant heat and heat conduction from flange)
Ambient humidityRelative humidity: 90% or less (no condensation)
DustAmbient criterion or less
Air purge

Instrument air (must not contain oil or mist; no dew formation)
Pressure: 0.2 to 0.25 MPa*

Air purge flow rate

60 L/min or more (depend on the process gas conditions)

VibrationAt 1 to 200 Hz, 1.96 m/s2 or less (excluding resonant frequency)
Process gas conditions

Temperature: 150 to 250°C

Pressure: 101.3 ± 10 kPa

Flow speed: 25m/s

Dust: 0.1mg/Nm3 or less

* This value is supplied pressure to TX-100 main unit.  In case air passes through the purge unit, the pressure value at the purge unit is 0.2 to 0.9 MPa.

Solid Waste Combustors and Incinerators in Solid Waste Management and Remediation Services
Solid Waste Combustors and Incinerators in Solid Waste Management and Remediation Services

Solicitud de Información

Tiene alguna pregunta o solicitud? Utilice este formulario para ponerse en contacto con nuestros especialistas.

* Estos campos son obligatorios.

Related products

ENDA-5000 series
ENDA-5000 series

Stack Gas Analysis System

51 series
51 series

Explosion-proof Gas Analyzer

AP-370 Series
AP-370 Series

Air Pollution Monitor

APCA-370
APCA-370

Ambient Carbon Dioxide Monitor

APHA-370
APHA-370

Hydrocarbon Monitor / THC Analyser

APMA-370
APMA-370

Ambient Carbon Monoxide Monitor

APNA-370
APNA-370

Ambient NOx Monitor

APNA-370/CU-2
APNA-370/CU-2

Ambient Ammonia Monitor

APOA-370
APOA-370

Ambient Ozone Monitor

APSA-370
APSA-370

Ambient Sulfur Dioxide Monitor

APSA-370/CU-1
APSA-370/CU-1

Ambient Hydrogen Sulfide Monitor

AQMS
AQMS

Ambient Air Quality Monitoring System

CEMS
CEMS

Continuous Emission Monitoring System

ENDA-5000 series
ENDA-5000 series

Stack Gas Analysis System

FTX-ONE-CL
FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

GA-370
GA-370

Trace Gas Monitor

GI-700 series
GI-700 series

Stack Gas Analyzer

IR-300
IR-300

Vapor Concentration Monitor

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

PG-300 series
PG-300 series

Portable Gas Analyzer

Process
Process

Process Analyzer System

VA-5000 / VA-5000WM Series
VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer

51 series
51 series

Explosion-proof Gas Analyzer

AP-370 Series
AP-370 Series

Air Pollution Monitor

AP-380 Series
AP-380 Series

Air Quality Monitor

APCA-370
APCA-370

Ambient Carbon Dioxide Monitor

APMA-370
APMA-370

Ambient Carbon Monoxide Monitor

BE-150
BE-150

OEM gas (CO/HC) analyzer

BE-220FSD
BE-220FSD

OEM gas (NO) analyzer

CEMS
CEMS

Continuous Emission Monitoring System

EMGA-921
EMGA-921

Hydrogen Analyzer

EMGA-Expert
EMGA-Expert

Oxygen/Nitrogen/Hydrogen Analyzer
(Flagship High-Accuracy Model)

EMGA-Pro
EMGA-Pro

Oxygen/Nitrogen Analyzer (Entry Model)

EMIA-Expert
EMIA-Expert

Carbon/Sulfur Analyzer
(Flagship High-Accuracy Model)

EMIA-Pro
EMIA-Pro

Carbon/Sulfur Analyzer (Entry Model)

EMIA-Step
EMIA-Step

Carbon/Sulfur Analyzer (Tubular Electric Resistance Heating Furnace Model)

ENDA-5000 series
ENDA-5000 series

Stack Gas Analysis System

ENDA-7000 Series
ENDA-7000 Series

Stack Gas Analyzer

GA-370
GA-370

Trace Gas Monitor

GI-700 series
GI-700 series

Stack Gas Analyzer

IR-300
IR-300

Vapor Concentration Monitor

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

LO-300
LO-300

Laser scanning oil film detector

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

OCMA-500
OCMA-500

Oil content analyzer

OCMA-550
OCMA-550

Oil content analyzer

PG-300 series
PG-300 series

Portable Gas Analyzer

TCA-5000
TCA-5000

Hydrogen Gas Analyzer

VA-5000 / VA-5000WM Series
VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer

Corporate