VS20-VIS

Miniature High Throughput Spectrometer

HORIBA designs and manufactures miniature high-throughput OEM spectrometers from 190 nm to 1700 nm for various applications. Thanks to a low stray light aberrations corrected concave holographic grating, the VS20-SYS platform offers in a 1.68 x 1.87 x 2 inches footprint a very reliable and robust spectrometer.

VS20 OEM spectrometers can be fully customized in sensors, entrance, slit size, electronics board, interface, etc. 

For OEM Industrial Applications

  •  Fluorescence
  •  Transmission and Reflectance
  • Examples:
    • Semiconductor Process Inspection
    • LED Testing
    • Color Measurement
    • Environmental monitoring
    • Food & Beverage Safety

 

*Available in select countries.

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

Segment: Scientific
Fabricant: HORIBA Scientific
  • Very compact and robust
  • Cost effective OEM solution
  • Mass production capability
  • Various wavelength ranges UV/VIS/VNIR/NIR
  • Low stray light
  • Customizable to customers'requirement

 

Quantum Efficiencies

 

OEM Spectrometer Selection Guide

View and Download our OEM Spectrometer Selection Guide

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

 

 

General Spectrometer Specifications
Spectral Coverage 390 – 770 nm extending to UV or NIR range is possible upon request
 
Spectrometer Resolution <4 nm with 50 μm slit width (Narrower slits available)
Spectral Dispersion 56.51 nm/mm (in average); 0.44 nm/pixel
Focal Length 20 mm
Options Selection of different high grade sensors : CMOS-APS*, CMOS-PPS** (PDA), optional
CCD on request
Input port: SMA, other options available upon request
F/# ~ F/2.7
Wavelength Accuracy <0.4 nm (using multi-area wavelength calibration)
Stray Light < 0.15%
Software LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration)

 

Detector Options and Specifications
Detector Type Hamamatsu CMOS-APS linear image sensor
S13014N with active pixel structure and global
e-shutter
Other detector options
such as CMOS-PPSs
with passive pixel structure
and full well up to several
100,000,000 e– and back
illuminated CCDs available
upon request.
See some options in the
table below.
Detector Sensor Format 512 x 1 pixels
Detector Pixel Size 14 μm x 200 μm
Detector QE refer to graphs below
Full Well Capacity 100,000 e¯ (typical)
80,000 e¯ (minimum
Readout Noise 16 e¯ (typical) to
20 e¯ (maximum)
Maximum Spectral Rate 44 spectra/s
ADC 16-bit
Dynamic Range (FW/RN) 7053:1
Non-linearity <1% (corrected)
Dark Current 375 e¯/pixel/s (typical)
500 e¯/pixel/s (maximum)
Communication USB 2
Environmental Conditions Operating temperature 0°C to 40°C ambient
Relative humidity <70% (non-condensing)
Storage temperature -25° C to 45° C
Power Requirements
AC/DC Power Supply (provided)
90-264 VAC, 47–63 Hz

 

Some CMOS-PDA Options (other sensors available upon request)
Sensor type S10113-256N S8378-256N S9226N-03 S9227N-03
Pixel format  25μm (W) x 500μm (H)
x 256 pixels
25μm (W) x 500μm (H)
x 256 pixels
7.8μm (W) x 125μm
(H) x 1024 pixels
12.5μm (W) x 250μm
(H) x 512 pixels
Detector QE refer to graphs below      
Linear Full Well (e-) ~94M e- (typical) ~43M e- (typical) ~1.9M e- (typical) ~3M e- (typical)
Readout Noise (e-) 5200 e¯ (typical) 3370 e¯ (typical) 390 e- (typical) 290 e- (typical)
Spectrometer housing will be slightly different depending on CMOS-PDA options

*Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW™ license is needed to run our acquisition software.
*APS stands for active pixel sensor CMOS (buried PD, high sensitivity similar to CCD)
**PPS stands for passive pixel sensor CMOS (surface PD, large full well capacity - replaces NMOS-PDAs)

 

Quantum Efficiencies

 

Mechanical Drawings

Download Mechanical Drawings

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.