CS-600F

Fiber Optic Type Chemical Concentration Monitor CS-600F

Fiber Optic Type Chemical Concentration Monitor

The CS-600F achieves a higher level of functionality best suited for manufacturing, such as the ability to perform in-line measurement of high temperature chemical solutions in various applications, stable operation for reduced downtime, and compact size for improved space productivity in order to meet the precise chemical solution concentration management required in leading-edge semiconductor wet process.

 

Segment: Semiconductor
Fabricant: HORIBA Advanced Techno Co., Ltd.

 

  • Reduced Sizes for More Flexible Layout
    The CS-600F monitor is compact in size; height has been reduced by 36%, volume by 40%, and the space required by the cell cables by 46% compared to previous models (CS-100F1 series).
    The light source unit and monitor main body can be installed remotely and in separate locations, which allows installation flexibility based on the locations of chemical solution unit and cleaning equipment.
  • High-stability, In-line Measurement of High Temperature Chemical Solutions (20 to 80℃)
    The all-new optical system and improved processing algorithms enable in-line measurement of high temperature chemical solutions, a critical step for leading-edge wet processes. This eliminates the need to cool-down the chemical sample., HORIBA’s CS-600F provides a high-stability, enables more efficient and precise chemical solution management.
  • Significantly Reduced Background Correction Frequency
    The regular correction frequency is significantly reduced compared to the previous model (CS-100F1 Series), which in turn significantly reduces unit downtime and greatly contributes to improved throughput.
  • A Single Monitor is Capable of Measuring Up to Six Types of Chemical Solutions (solution types or ranges)
    A single monitor can measure up to six types of chemical solutions (solution types or ranges). Solution types and ranges can be freely specified, enabling the CS-600F to meet a wide variety of monitoring requirements.
  • Capable of Outputting Measured Values of Up to Six Components (Serial Output)
    The previous model (CS-100F1 Series) was able to output four components (serial output). This new model can output up to six components through the serial output. Analog output of new model is four components versus two on the previous model.

 

 

ModelCS-600F
Measurement
principle
Absorption spectroscopic method
Calculation
principle
Temperature compensation type multivariate analysis
Measurement targetNH3/H2O2/H2O (reperesentative specification)
* Please contact HORIBA regarding other chemicals.
Measurement rangeNH3:0.00~1.20mass%、H2O2:0.00~5.50mass%、
H2O:93.3~100.0mass%
RepeatabilityNH3:±0.05mass%、H2O2:±10mass%、H2O:±1.0mass%
Chemical temperature: Within ±1℃/1 hour
Sample solution
temperature
20〜80℃
Measurement cycleApprox. 3 seconds
LCD
display
(1) Measured value (%)
(2) Concentration alarm (HH/H/L/LL)
(3) Error code (EXXX)
(4) Chemical temperature (°C)
(5) Serial/parallel communication status (P/S)
(6) The times of background correction failure (CXXX)
Key input(1) Concentration alarm setting (HH/H/L/LL)
(2) Concentration value shift
(3) Background correction
(4) Hot water correction
(5) Temperature dependent concentration shift
Parallel
input
Input voltage of 12 V to 30 V DC by insulating with photo coupler
(1) Parallel concentration alarm output (On/Off)
(2) Switching chemical solution for measurement
(including background correction)
(3) Hot water correction
Parallel
output
Transistor output (NPN open collector) by insulating with photo coupler
Maximum current when powered ON: 5 mA DC (no internal protective resistance)
Maximum voltage when powered OFF: 30 V DC
(1) Concentration alarm (ON at HH/H/L/LL alarm)
(2) Monitor error (OFF at error)
(3) Measuring (ON at measurement)
(4) Chemical solution type for measurement
(5) Echo to hot water correction input
(6) Warning (ON at occurred)
(7) Background correction status 8) Hot water correction status
Serial inputRS-232C
(1) Request for readout of measurement data
(2) Select chemical solution type to be measured
(3) Hot water correction
Serial
output

RS-232C
(1) Measured data No.
(2) Chemical solution type
(3) Concentration value
(4) Error code
(5) Chemical temperature

Analog
output
4 mA to 20 mA
In case of monitor error occurs, measurement is stopped or
invalid chemical range is selected, the signal output is fixed at 1.5 mA. The load resistor must be 500 Ω maximum.
Chemical solution
temperature input
Terminal block inlet (terminal screw M3)
Platinum resistance temperature sensor: Pt100
(Three-conductor type, Class A) *Temperature sensor is not included.
Air
(for operation and purge)
Connection port: 4 mm O.D. quick joint,
Pressure: 0.2 MPa ±0.02 Mpa
Power source100~230V AC(Single-Phase)、50/60Hz
Power consumptionApprox. 85 VA
(transient electric current at the time of the start is excluded)
Weight(Monitor) Approx. 3.6 kg
(Lamp unit) Approx. 2.8 kg
(Sample cell) Approx. 1.2 kg
Ambient temperature(Monitor, Lamp unit) 20°C to 30°C
(Sample cell, Optical fiber) 20°C to 35°C
(Sudden temperature change should be avoided, within ±1°C/1 hour)
Ambient humidity(Monitor, Lamp unit, Sample cell) 40% to 70%
(Should be no dew condensation)
Slanting angle at installation(Monitor, Lamp unit) within ±1°
Optical fiberLength: 5 m, minimum bend radius: R 150 mm

Schematics


 

Request for Information

Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

Related products

CS-100 Series
More CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-100F1 Series
More CS-100F1 Series

Fiber Optic Type Chemical Solution Concentration Monitor

CS-620F
More CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-700
More CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
More CS-900

Non-Contact Chemical Concentration Monitor

HD-960L
More HD-960L

Dissolved Oxygen Monitor in Low Concentration

HD-960LR
More HD-960LR

Dissolved oxygen concentration monitor series for semiconductor manufacturing

HE-200C
More HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-300C
More HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
More HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
More HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480R
More HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HE-480R(W)
More HE-480R(W)

Industrial resistivity meter

HE-960CA
More HE-960CA

Citric Acid Monitor

HE-960H-TM
More HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
More HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
More HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960LC
More HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
More HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity meter

HE-960R-GC(W)
More HE-960R-GC(W)

Carbon Sensor Resistivity Meter

HE-960RW-GC(W)
More HE-960RW-GC(W)

2-Channel Resistivity Meter

HE-960TM
More HE-960TM

TMAH Conductivity Meter. Perfect for Controlling TMAH Developer Concentrations

HF-960EM
More HF-960EM

In-line Sensor & Auto Range Switching Concentration Monitor

HF-960H
More HF-960H

HF / HCl Concentration Monitor

HF-960M
More HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HF-SP-CU
More HF-SP-CU

2-channel High Precision HF Concentration Monitor

HP-480(W)
More HP-480(W)

Industrial pH meter

HZ-960
More HZ-960

Dissolved Ozone Monitor

SLIA-300
More SLIA-300

Highly Sensitive Silica Monitor

UP-100
More UP-100

Micro Volume pH Monitor

CS-100 Series
More CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-100F1 Series
More CS-100F1 Series

Fiber Optic Type Chemical Solution Concentration Monitor

CS-620F
More CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-700
More CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
More CS-900

Non-Contact Chemical Concentration Monitor

EG-100
More EG-100

Washwater Monitoring System

HC-200F
More HC-200F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Four-Wire Transmission)

HC-200NH
More HC-200NH

Field-installation Type Ammonia Nitrogen Meter(Four-Wire Transmission)

HC-300F
More HC-300F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Two-Wire Transmission)

HD-200
More HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-200FL
More HD-200FL

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Optical Type)

HD-300
More HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-480
More HD-480

Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-960L
More HD-960L

Dissolved Oxygen Monitor in Low Concentration

HD-960LR
More HD-960LR

Dissolved oxygen concentration monitor series for semiconductor manufacturing

HE-200C
More HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-200H
More HE-200H

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)

HE-200R
More HE-200R

Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)

HE-300C
More HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
More HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
More HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
More HE-480H

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480R
More HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HE-480R(W)
More HE-480R(W)

Industrial resistivity meter

HE-960CA
More HE-960CA

Citric Acid Monitor

HE-960CW
More HE-960CW

Panel-mount Type Conductivity Meter (Four-Wire Transmission, 2-channel)

HE-960H-TM
More HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
More HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
More HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
More HE-960HI

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Wide Range)

HE-960LC
More HE-960LC

Carbon Sensor Conductivity Meter

CS-100 Series
More CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-100F1 Series
More CS-100F1 Series

Fiber Optic Type Chemical Solution Concentration Monitor

CS-620F
More CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-700
More CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
More CS-900

Non-Contact Chemical Concentration Monitor

EG-100
More EG-100

Washwater Monitoring System

HF-960M
More HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HU-200SS
More HU-200SS

Field-installation Type MLSS Meter (Four-Wire Transmission)

HU-200TB-H
More HU-200TB-H

Field-installation Type Turbidity Meter (Four-Wire Transmission, High-sensitivity)

HU-200TB-IM
More HU-200TB-IM

Field-installation Type Turbidity Meter (Four-Wire Transmission, Immersion Type)

HU-200TB-W
More HU-200TB-W

Field-installation Type Turbidity Meter (Four-Wire Transmission, For Wide Range)

HZ-960
More HZ-960

Dissolved Ozone Monitor

OPSA-150
More OPSA-150

Organic Pollutant Monitor

TPNA-500
More TPNA-500

Automatic Total Nitrogen/Phosphorus Monitoring

U-50
More U-50

Multi-parameter Water Quality Checker

VUV Transmission
More VUV Transmission

Use of H20UVL for VUV transmission