HR-200RT

Field-installation type residual chlorine meter

HORIBA's long-selling water quality meter that excels in indoor applications.

Ideal for measuring the concentration of free residual chlorine in tap water, swimming pools, spas and similar environments. By adopting physical polishing cleaning with rotating electrodes, long-term stable measurements can be achieved.

Division: Process Water
Fabricant: HORIBA Advanced Techno Co., Ltd.

Parts can be replaced without the use of tools

Consumables (cathode electrode, filter, beads) can be replaced without the use of tools.

Equipped with rotation stop detection function and re-rotation function

If the rotating sensor stops, an error message will be displayed. Additionally, it will automatically initiate re-rotation.

Equipped with pH correction function

The HORIBA pH meter (HP-200) can be connected, applying pH correction to the residual chlorine measurement values.

Converter

Product nameResidual Chlorine Monitor
ModelHR-200RT
Sensor typeRA-30
Measurement
range
Concentration0 mg/L to 3 mg/L (Display range: 0 mg/L to 5 mg/L)
Temperature0℃ to 50℃ (Display range: -10℃ to 110℃)
Display
resolution
Concentration0.01 mg/L
Temperature0.1℃
PerformanceConcentrationRepeatabilityWithin ±0.05 mg/L (Equivalent input)
LinearityWithin ±0.05 mg/L (Equivalent input)
TemperatureRepeatability±0.5℃ (Equivalent input)
Linearity±0.5℃ (Equivalent input)
Transmission
output
Number of current outputs2 (Negative terminals of each transmission output channel are connected inside and thus have the same electrical potential)
Output type4 mA to 20 mA DC, input/output isolated type
Load resistance900 Ω (Max.)
LinearityWithin ±0.08 mA (limited to the current linearity)
RepeatabilityWithin ±0.02 mA (limited to the current repeatability)
Output rangeOutput 1Residual chlorine concentration: An arbitrary value can be set within the range from 0 mg/L to 5 mg/L
Output 2Temperature: An arbitrary temperature can be set within the range from -10℃ and 110℃
Error outputProvided with burnout function (3.8 mA or 21 mA)
Hold functionSelectable from between the latest value hold and the preset value hold
Contact outputNumber of current outputs4
Output typeNo-voltage output contact
Contact typeRelay contact, R1 to R3: SPST (1a), FAIL: SPDT (1c)
Output capacityR1, R2, FAIL: 250 V AC 3 A/30 V DC 3 A (resistance load)
R3: 30 V DC 1 A (resistance load)
Contact
function
R1, R2, R3Selectable from among the upper limit alarm, lower limit alarm, ON/ OFF control, during transmission output hold, and during calibration
(closed at alarm operation, open under normal conditions and in a power-OFF state)
FAILError alarm (closed under normal conditions, open in an error or power-OFF state)
Description of alarm operation
  • Setting range: 0.00 mg/L to 3.00 mg/L
  • Delay time: 0 s to 600 s
Description of control operation
  • Setting range: 0.00 mg/L to 3.00 mg/L
  • Control width: 0.02 mg/L to 1.00 mg/L (±0.01 mg/L to 0.50 mg/L)
Contact inputNumber of input points2
Contact typeOpen collector no-voltage “a” contact
ConditionON resistance: 100Ω (max.)
Open-circuit voltage: 24 V DC
Short-circuit current: 12 mA DC (max.)
Contact functionSelectable from among the external input for transmission output hold, flow switch input for interlock (open when the flow rate drops), and calibration command
Communicati
on function
typeRS-485
Number of circuits1
Signal formTwo wire type, the power source of the communication is isolated from the power of measurement circuit (the power source of transmission and communication are not isolated).
pH correctionTypeConnected with expansion connector
pH correction range5.8 pH to 8.6 pH
Temperature
compensation
Applicable temperature elementPt1000: 1 kΩ (0℃) (embedded in the detector unit)
Compensation range0℃ to 50℃
Calibration functionOne point calibration compared with reference temperature range
CalibrationCalibration methodZero calibration (with zero water)
Span calibration (comparative calibration with the value measured with the DPD method including electrical zero calibration)
Additional functionCalibration log (number of days elapsed since the zero or last calibration), calibration error automatic judgment (zero)
Calibration
control output
(ZERO CAL)
Number of contact output1
Output typeVoltage contact output (connected power source voltage output)
Contact capacity250 V AC 0.5 A
Calibration cycle setting1 hour to 999 hour
CALR1Contact typeRelay contact, SPST (1a)
Contact functionZero water switching driven by solenoid valve
Self-checkCalibration errorZero calibration error, outside the temperature calibration range
Temperature sensor diagnosisTemperature sensor short-circuit, temperature sensor disconnection
Converter errorCPU abnormality, ADC abnormality, memory abnormality
Operating temperature range-20℃ to 55℃ (without freezing)
Operating humidity rangeRelative humidity: 5% to 90% (no condensation)
Storage temperature-25℃ to 65℃
Power supplyRated power supply voltage100 V to 240 V AC ±10% 50/60 Hz
Power consumption35 VA (max.)
OthersWith built-in power switch for maintenance
StructureInstallationOutdoor installation type
Installation methodPole-mounted or wall-mounted
Protection classIP65
Material of caseAluminum alloy (coated with epoxy-modified melamine resin)
Material of mounting bracketsSUS304
Material of sun shade hoodSUS304 (coated with epoxy-modified melamine resin)
Material of display windowPolycarbonate
Display elementReflective monochrome LCD
External dimensions180 (W) mm × 155 (H) mm × 115 (D) mm (excluding brackets)
MassMain frame: approx. 3.5 kg, Hood, bracket: approx. 1 kg

Note

Although an arrestor (400 V discharge starting voltage) is mounted for the transmission output, contact input, and communication, install an optimum surge absorber element on the connection line, depending on the surrounding environment, device installation conditions, and externally connected devices.

Detector and measuring cell

Product nameRotating electrode polarographic residual chlorine sensor
ModelRA-30
Measurement methodRotating electrode polarographic method
Measurement targetFree residual chlorine in sample water
Measurement range0 mg/L to 3.00 mg/L
Temperature compensationAutomatic temperature compensation using Pt1000
PerformanceLinearityWithin ±5% full-scale range
RepeatabilityWithin ±2% full-scale range or ±0.05 mg/L, whichever is larger
Response timeWithin 120 s from the inlet of the measuring cell (90% response)
Zero driftWithin ±1% full-scale range/month
Span driftWithin ±10% full-scale range/month
Sample
condition*6
Temperature0℃ to 45℃
Flow rateMeasuring cell flow rate: 0.1 L/min to 0.5 L/min*1
Primary pressure0.01 MPa to 0.15 MPa*2
pH value5.8 pH to 8.6 pH (with no fluctuation over 1.0 pH)*3
Electrical conductivity8 mS/m or more*4
CalibrationZero calibrationZero water calibration, electrical zero calibration
Span calibrationComparative calibration with the value measured with the DPD method
(including electrical zero calibration)
Material of
liquid contact
section
ElectrodeAu, AgCI
BeadsCeramic beads
FilterNylon
OtherPVC, PPO, PTFE, EPDM, Q
Piping
connection
sample inletφ6 mm × φ8 mm tube or Rc1/8
sample outletVP16
Cleaning methodPhysical cleaning with beads
Cable lengthProvided standard cable: 1.5 m, max. extension distance: 10 m
Operating temperature range0℃ to 45℃*5
Operating humidity rangeRelative humidity: 5% to 90% (no condensation)
Storage temperature0℃ to 45℃
StructureInstallation method50 A pole-mounted or wall-mounted
Protection classIP53
External dimensions110 (W) mm × 340 (H) mm × 110 (D) mm (excluding brackets)
MassApprox. 1.5 kg
Standard accessoriesBeads, abrasive paper, mesh filter (2 types), O-ring

1: If use our designated flow switch (RA-FS30), regulate flow rate in 0.3 L/min to 0.5 L/min.
2: The measurement section is under an open air environment.
3: If pH of the measured sample varies, the value of residual chlorine also varies. Perform measurement in an environment in which pH variations are less likely to occur.
4: Measurement cannot be performed correctly when the electrical conductivity falls below 8 mS/m (80 μS/cm). Be sure to perform measurement in this conditions.
5: If the electrode is exposed to the direct sunlight, the anode and cathode electrode could deteriorate. Install the instrument where it is not exposed to direct sunlight (indoors).
6: If a reducing agent or oxidizer exists in a sample, it affects the reading. Do not use a sample containing a reducing agent such as thiosulfate or sulfite, or oxidizer such as O3, hydrogen sulfide or chlorine dioxide, as measurement cannot be performed correctly.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HC-200F
HC-200F

Field-installation Type Fluoride Ion Concentration Meter

HC-200NH
HC-200NH

Field-installation type ammonia nitrogen meter

HC-300F
HC-300F

Field-installation Type Fluoride Ion Concentration Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-200FL
HD-200FL

Field-installation type optical dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

HE-960RW-GC
HE-960RW-GC

2-Channel Resistivity Meter

HF-700A
HF-700A

Low Concentration Monitor- Sulfuric Acid/Hydrogen Peroxide

HF-960H
HF-960H

HF / HCl Concentration Monitor

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HO-200
HO-200

Field-installation type ORP meter

HO-300
HO-300

Field-installation type ORP meter

HO-480
HO-480

Panel-mount type ORP meter

HR-200
HR-200

Field-installation type polarographic residual chlorine meter

HR-480
HR-480

Panel-mount type galvanic residual chlorine meter

Corporate