discontinued Ce produit a été abandonné et n'est plus disponible. Vous pouvez toujours accéder à cette page à des fins d'information.

PGM1000

Vacuum Spectrometer -Monograph to explore the 1- 125 nm

The Plane Grating Monochromator/Spectrograph (PGM-PGS) series is a unique optical design coupling a toroïdal mirror and an aberration corrected rotating plane grating. Each grating has been especially designed thanks to our Imaging CorrectionPLUS Technology, to have a perfect coupling with its associated toroïdal mirror. Compared to a Rowland-Circle configuration, this solution features two major advantages: firstly it can be used both in multichannel mode (real flat field) and in single channel (with an exit slit); secondly the optical design is straight (entrance and exit arms parallel) and the exit (whether detector or slit) is fixed which makes integration and calibration very easy.

With a large choice of gratings (both master and replica) the PGM/PGS series covers a large VUV range from 2 to 125 nm.

 

 

•     Imaging CorrectionPlus Technology
•    On Axial optical design
•     Choice of master or replica gratings
•     Kinematic Grating Mount or three gratings slider
•    CCD port mounted on X table
•    Patented layout
•    High vacuum compatible

 

Benefits

•     The best image on your CCD over 25 mm focal plane
•     Less room needed and easy to align
•     Optimize damage threshold or cost
•    Interchangeable gratings
•    In vacuum focus adjustment
•     Use grazing incidence angles onto the optics and  normal incidence for CCD illumination
•    5 10-6 mbar– option 5 10-9 mbar

Monograph with 1000 mm focal length to cover the 2-126 nm spectral range.

Optical design

Toroidal Mirror and Plane Grating VLS Type

Focal length

1000 mm

Aperture

f/50

Gratings

1800 gr/mm : 2-35 nm (8-35 nm in monochromator mode)

550 gr/mm : 7-126 nm (30-125 nm in monochromator mode)

Optic coating

Pt or Au

Deviation angle

156°

Dispersion

1800 gr/mm : 0.09 nm/mm at 8 nm

550 gr/mm : 0.3 nm/mm at 30 nm

Drive

Sine arm

Vacuum

5 10-6 mbar (HV version)

5 10-9 mbar (UHV version)

Pumping flange

DN63 CF (DN100 CF)

Entrance port

Micrometric slits (10 µm to 2 mm)

Entrance flange

DN40 KF (DN40 CF)

Exit port

Micrometric slits (10 µm to 2 mm) or Adjustable CCD port

Exit flangeDN40 KF (DN40 CF) for slit version
DN100 CF for CCD version
PC interfaceBuilt-in USB2 (no additional controller)

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

1000M Series
1000M Series

Long Focal Length Spectrometer

Blazed holographic plane gratings
Blazed holographic plane gratings

OEM gratings design and production capabilities

CP20 Series
CP20 Series

OEM miniature spectrograph

DeltaRAM X
DeltaRAM X

Random Access Monochromator

EV 2.0 Series
EV 2.0 Series

Endpoint / Chamber Health Monitor based on Optical Emission Spectroscopy and MWL Interferometry

EV-140C
EV-140C

Optical Emission Spectroscopy Etching End-point Monitor

FHR Series
FHR Series

High Resolution Monochromators

Flat field and imaging gratings - Type IV
Flat field and imaging gratings - Type IV

OEM gratings design and production capabilities

GD-Profiler 2™
GD-Profiler 2™

Le spectromètre d'émission optique à décharge luminescente ouvre de nouveaux horizons d'information

Gemini 180
Gemini 180

Double monochromator

Gratings - Laser Pulse Compression Gratings
Gratings - Laser Pulse Compression Gratings

Pulse compression gratings using holographic techniques

Gratings for Space-Flight
Gratings for Space-Flight

Space qualified and TRL9

Holographic concave gratings - Type I
Holographic concave gratings - Type I

OEM gratings design and production capabilities

Holographic plane gratings
Holographic plane gratings

OEM gratings design and production capabilities

iHR Series
iHR Series

Mid-Focal Length Imaging Spectrometers

LEM Series
LEM Series

Camera Endpoint Monitor based on Real Time Laser Interferometry

LSH Illuminator
LSH Illuminator

Compact Deuterium, Tungsten Halogen or Glow Bar Light Source

Lumetta compact spectrograph
Lumetta compact spectrograph

High Sensitivity Imaging Spectrograph

MicroHR Series
MicroHR Series

Short Focal Length Imaging Spectrometers

Monochromator gratings - Type IV
Monochromator gratings - Type IV

OEM gratings design and production capabilities

Pentra C200
Pentra C200

Clinical Chemistry Analyzer

Pentra C400
Pentra C400

Clinical Chemistry Analyzer

PoliSpectra® VS70 Dual & Quad
PoliSpectra® VS70 Dual & Quad

DUAL & QUAD CCD Mini-Spectrometer

PowerArc
PowerArc

Broadband Xe Light Source

RU-1000
RU-1000

Plasma Emission Controller

Ruled plane gratings
Ruled plane gratings

OEM gratings design and production capabilities

Spectrometers - LIBS spectrometers
Spectrometers - LIBS spectrometers

Laser-induced Breakdown Spectroscopy (LIBS)

Tunable PowerArc
Tunable PowerArc

Tunable 75W Xe Light Source

Yumizen C230
Yumizen C230

Clinical Chemistry Analyzer

Yumizen C240
Yumizen C240

Clinical Chemistry Analyzer

Yumizen C560
Yumizen C560

Clinical Chemistry Analyzer