Patient Demography: Female aged 72

Symptoms: Bilateral lower limb pain? CML

Diagnosis: Chronic Myeloid Leukemia in Blast Crisis

Microscopy: Blast-70%, Lymphocyte-04%, Monocyte-03%, Neutrophil-06%, Eosinophil-02%, Basophils-05%, Promyelocytes-03%, Myelocytes-04%, Metamyelocytes-03%

Other Tests: BCR ABL t (9:22) Philadelphia Chromosome – POSITIVE, MTHFR Gene mutation – POSITIVE

How Yumizen Can Assist: 1. On the DIFF scattergram, we observe a compact blast population between the lymphocyte, atypical lymphocyte, and monocyte areas. The small to moderate-sized blasts are situated in the ALY area. These blasts have basophilic cytoplasm with irregular nuclear contours and contains 2 to 3 nucleoli. 2. WBC distribution histogram also suggests the presence of basophils, which is confirmed in the manual differential count.

(Picture) Test results monitor screen

Microscopy findings showed small to moderate-size blasts having basophilic cytoplasm and irregular nuclear contours with 2 to 3 nucleoli. Basophils were also seen.

This clinical case has been provided by Dr. Sonal Gupta, Lab Head & Pathologist, Redcliffe Diagnostic Lab, Mumbai, India.

HORIBA Medical Chase the Case #15 - Acute Myeloblastic Leukemia

Subscribe Chase the Case

Subscribe and receive the latest Chase the Case by e-mail every month. Once subscribed, you will start to receive it from the next issue.

Subscribe
Yumizen H2500 Hematology Analyzer-V2 logo-HORIBA Medical

Yumizen H2500/H1500 Hematology Analyzer

Mastering the analyzis process to deliver reliable results

more

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Corporate