Hyperspectral PoliSpectra® H116

PoliSpectra H116 -Hyperspectral Imaging Spectrometer

Hyperspectral Imaging Spectrometer Applications

HORIBA has developed a unique hyperspectral imaging spectrometer with an integrated scientific CMOS camera (12-16 bit) featuring HDR (95dB Dynamic Range and 1.7e- noise) and 95% Q.E peak efficiency:

PoliSpectra® H116 features broad UV-NIR coverage in one acquisition (185-1050 nm) combined with the highest spectral resolution (<1 nm).

The elegant all-concentric design combines high spatial and spectral resolution using a type-I holographic diffraction grating. This system is used as a line-scanning instrument (push-broom) that collects full spectral data simultaneously, across the input slit height at 188 frames per second (or higher with AOI/binning).

For OEM hyperspectral and multispectral applications

  • Remote Sensing (Aerial - drone/uas/uav or aircraft…)
  • Quality Control Inspection / Optical metrology in Semiconductors
  • DNA sequencing / Capillary Electrophoresis / PCR
  • Process Monitoring by Reflectometry, Emission, Raman, Fluorescence…
  • Microscopy (Mapping, Complete custom solutions)
  • Advanced Machine Vision / Industrial camera
  • Recycling (Sorting and quality control in recycling plants)
  • Food & Beverage Inspection

 

Alternatively, we offer H135, a more compact product with less spectral resolution and coverage

*Available in select countries.

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

Segment: Scientific
Výrobní společnost: HORIBA Scientific
  • Superb imaging quality
  • Frame rates as fast as 188 fr/s 
  • High spectral and spatial resolution at F/2.3
  • High throughput combined with low stray light performance
  • 2D Scientific CMOS with high quantum efficiency and low noise
  • Broad wavelength coverage from 185 nm to 1050 nm
  • Stable and robust

 

Thermal stability study cycling from -20ºC to 50ºC

 

Scientific CMOS Back-Illuminated Sensor Quantum Efficiency

 

Hyperspectral Imaging Distortions: Keystone and Smile

View Hyperspectral Imaging Distortions: Keystone and Smile

 

OEM Spectrometer Selection Guide

View and Download our OEM Spectrometer Selection Guide

 

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

 

 

General Spectrometer Specifications*
Spectral Coverage185–1050 nm
Tunable at factory between these ranges: 185-920 nm and 280-1050 nm
Spectral Resolution 1.25 nm typical (22 μm slit width) and up, depending on the slit size
Spatial Resolution50 µm typical
Spectral Dispersion34.6 nm/mm; 0.38 nm/pixel
Focal Length116 mm
F/#F/2.3
Smile and Keystone1.5 pixel (typical)
Stray Light**< 0.1% (typical)
Wavelength Accuracy0.1 nm (using multi-area wavelength calibration)
SoftwareLabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration)

 

Specifications for Scientific Back-Illuminated CMOS Image Sensor with High Speed Electronics
Detector ModelsCMOS BI sensor with electronic rolling shutter (All the parameters are specified at normal room temperature of 25º C unless otherwise noted)
Sensor Format***2048 x 512
CMOS Pixel Size11 µm x 11 µm
CMOS Height5.6 mm
CMOS QEThe peak QE is 77% at 250 nm and 95% at 560 nm (refer to graphs below)
Thermoelectric CoolingUncooled
Frame Rate94 fps (HDR mode), 188 fps (STD mode) on 2D sCMOS sensor
Full Well80 ke¯ typical (HDR mode)
Readout Noise1.6 e¯ typical, 2.0 e¯ maximum
Digitization16-bit (HDR mode), 12-bit (High Sensitivity mode
Dynamic Range (HDR mode)93.9 dB typical in HDR mode
Non-linearity
(measured on each system)
< 1.8% (maximum) in HDR mode  <0.9% (maximum) at high gain
CommunicationUSB 3
Environmental ConditionsOperating temperature 15° C to 40°C  ambient; 
Relative humidity <70% (non-condensing); Storage temperature -25° C to 45° C
Power requirements
AC/DC Power Supply (provided)
90-264 VAC, 47–63 Hz


* Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW license is needed to run our acquisition software.
** Stray light using BP Filter: Baseline light level, outside the band, divided by BP peak (unsaturated) value.
*** See sensor manufacturer’s Blemish / Defect information

 

Scientific CMOS Back-Illuminated Sensor Quantum Efficiency

Mechanical Drawings

Download Mechanical Drawings

 

 

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

Požadavek na informaci

Máte nějaké dotazy nebo požadavky? Pomocí tohoto formuláře kontaktujte naše specialisty.

* Tato pole jsou povinná.