EMGA-600W Oxygen/Nitrogen/ Hydrogen Combined Analyzer

Overview

The HORIBA EMGA-600 is a combined model between ON and H analyzers and determines the oxygen, nitrogen and hydrogen contained in ferrous and non-ferrous metals, semiconductors, electronic materials and so on using the inert gas fusion method.

The oxygen is measured as carbon monoxide by a non-dispersive infrared detector and the nitrogen and hydrogen are measured by a thermal conductivity detector. The detectors for O/N/H are connected to the same single furnace through a gas selection unit.

Features

  • Different analysis modes for different samples

  • Precision control of extraction furnace

  • Multistep slope power control

  • Real-time temperature hold function

  • Temperature programmable pattern memory function

  • Peak level setting function

  • Multifunctional graphic printout

  • Dual sample/flux introduction mechanism (HORIBA patent)


Manufactured by HORIBA

Specifications

EMGA-600W: Oxygen,Nitrogen, Hydrogen analyzer

Principle
Iner gas fusion in impulse furnace
Oxygen: NDIR
Nitrogen&Hydrogen: TCD

Range
Oxygen: 0-0,1%
Nitrogen: 0-0,5%
Hydrogen: 0-0,02%  
Up to 100% wt is possible by decreasing the sample weight.

Accuracy
Oxygen/Nitrogen (For standard sample)
σn-1≦0.0001%(m/m) (Sample conc.is under 0.002%(m/m))
σn-1≦0.00015%(m/m) (Sample conc.is 0.002%(m/m) and above) or CV≦1.5%

Hydrogen (Reference gas)
σn-1≦0.04ppm(m/m) or CV≦1,0%

Sample weight: 1,0g standard

Sensitivity
Oxygen/Nitrogen: 0,01ppm
Hydrogen: 0,001ppm

Analysis time
Oxygen/Nitrogen: Approx. 40sec from gas extraction to measurement result display
Hydrogen: Approx. 100sec from gas extraction to measurement result display
Depending on the sample and extractions.

Analysis conditions
Extraction conditions:
Furnace control:Electrical power control
 Wattage setting 
 Temperature setting

Operation mode:2 operation modes are available depending on the sample
 Block mode
 Power mode

Integration conditions:
3 integration methods are available.
 Preset time integration
 Integration up to reach comparator level
 Preset time integration or integration up to reach comparator level, whichever is shorter

Calibration
One-point or multi-point (up to 30 points) calibration using standard sample
Option:Gas dosing calibration

Extruction furnace
Furnace structure
Enable to set the generating power 0-8kw
Enable to temperature programmed analysis in controlling temperature, power current and electricity.
Internal cooling water circulation method

Functions
Interrupt analysis
Alarm display
Data storage (Preset list up to 100 items, Result up to 1000 per file)
Memory of calibration curve and measurement conditions
Out put (RC-232C)
Furnace control: 10 furnace control patterns can be programmed
Self diagnosis

Automation function
Autocleaning function (Option)

Power
Main unit: 200/220/240V, 50/60Hz
PC:100/120/200/220/240V, 50/60Hz

Dimensions
2Analyzer unit 450W×920D×725H (By one unit)  
Combustion unit: 550W×920D×725H

Weight
Analyzer unit: approx 100kg  Combustion unit: approx 170kg

Schematics

EMGA-600W Schematics

Related Products

EMGA-920

This is an oxygen and nitrogen elemental analyzer with high accuracy and repeatability suiting to...

EMIA-8100 series

EMIA-8100 series equipped with electrical resistance furnace measures carbon and sulfur contained...

GD-Profiler

The GD-Profiler 2™ provides fast, simultaneous analysis of all elements of interest including the...

GD-Profiler HR

The HORIBA Scientific GD-Profiler HR™ gives the optimum in terms of resolution and number of...

Assistance tools with ICP-OES

ACTIVA-M, a bronze award winner for best new product at Pittcon 2007 as Master in multi-line...

SLFA-2100/2800

The SLFA-2100/2800 are designed specifically to meet the recent demanding needs of measuring the...

XGT-5200WR

High sensitivity XRF qualitative and quantitative analysis with an X-ray imaging...

XGT-7200

Single point analysis and automated hyperspectral imaging.

Dual vacuum modes.

Spot sizes from 1.2...

XGT-5200

Single point analysis and automated imaging.

Atmospheric pressure analysis.

Spot sizes from 1.2...