ABX Pentra XL 80

  • Ideal for "hot lab" working
  • 칼라 터치 스크린 Workstation 장착
  • 전혈 micro-sampling (CBC : 30 μL - DIFF: 53 μL) 
  • Cytochemistry, Impedance(실제 세포수를 측정) & Optical(광학도를 측정함에 따라 세포내부의 구조를 분석)-DHSS* Technology
  • 혈액 검체와 시약의 완벽한 혼합 - MDSS* Technology
Segment: Medical
Division: Hematology
Manufacturing Company: HORIBA ABX SAS

ABX Pentra XL 80

  • 시간당 80 검체 처리
  • 대용량의 Auto-Loader (100 tubes)
  • Open/closed 튜브에서의 응급 검체 sampling
  • 자동 재검
  • 총 4 개 시약 과 1 개 희석제 장착
  • DHSS*기술로 5DIFF 를 완벽하게 분획
  • 5 DIFF Matrix와 함께 RBC, BAS/WBC, PLT 의 3 히스토그램을 보여줌
  • Basophil 별도 채널에서 측정
  • 비정형림프구(ALY***)와 미성숙세포(LIC***)는 높은 해상도의 Matrix에 분획으로 나타남(%, #)
  • 검체 희석률 자동 지정 시스템
  • Validation Station 장착 

* DHSS : Double Hydrodynamic Sequential System (HORIBA Medical Patent)
** MDSS : Multi-Distribution Sampling System (HORIBA Medical Patent)
*** RUO parameters (Research Use Only)

Technical

Weight122 lb, 55 kg.
Power supply100 V to 240 V (± 10%) - 50 Hz to 60 Hz
Dimensions

22 in x 34.1 in x 23.3 in / 54 cm x 82 cm x 57 cm.

PrinterLaser
Throughout80 tests/hour.
Data management

Colour LCD touch screen: 12 in.
PC onboard: Celeron 650 MHz.
Windows XP Prof.TM
RAM (256 Mo), Hard disk (10 Go mini)
Floppy disk & CD-ROM reader
RS 232C, 2 x USB1
User-defined flagging limits
Transmit patient files & QC to LIS
Uni-directional & bi-directional connections
ASTM protocol inside

Memory

10 000 results + graphics

Quality Control
Management
24 selectable QC files
XB: 60 Operator selectable batches with statistics (20 samples per batch)
With-in run
Levey-Jennings Graphs
LogsReagents, Quality Control, Calibration, Maintenance, Blank Cycle, Patients Data, Settings,
Information, Technology Communication, Errors, by date.
Patient reports
Management
Delta check
Anteriority (Matrix, curves, data)
Manual input

Samples

80 samples/hour (open or closed tube)
Parameters (26)WBC, NEU# & NEU%, LYM# & LYM%, MON# & MON%, EOS# & EOS%, BAS# & BAS%, ALY# &
ALY%*, LIC# & LIC%*, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, MPV, PCT*, PDW*. 
GraphsHigh-definition LMNE matrix
PLT, RBC, WBC/BAS curves.

Blood Volume

CBC mode : 30 μL
CBC + DIFF mode : 53 μL

Stability48 hours post-draw stability
Operating sample mode

Autoloader 10 racks (100 tubes) capacity
Sample mixing with end-over-end tube rotation
Closed or open STAT tube

IdentificationAlphanumeric. Bar-code reader (optional)

 * RUO parameters (Research Use Only)

Results

ParametersPresicion (cv %)Linearity limitsLinearity Limits with CDR*
WBC< 2.00-120 x 10³/µL120-360 x 10³/µL
RBC< 2.00-8 x 106/µL0-8 X 106/µL
HGB< 1.00-24 g/dl0-24 g/dL
HCT< 2.00-67%0-67%
PLT (whole blood)< 5.00-1900 x 10³/µL1900-3800 x 10³/µL
PLT (PLT concentrate)< 5.00-2800 x 10³/µL2800-5600 x 10³/µL

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Product accessories

Accreditation Folder (ISO)
Accreditation Folder (ISO)

Accreditation Support

CellaVision®
CellaVision®

Digital Cell Morphology Systems

Hematovision
Hematovision

Accreditation Support

Quality Control Program (QCP)
Quality Control Program (QCP)

Accreditation Support

RAL SmearBox
RAL SmearBox

Blood Smearing Device

RAL StainBox
RAL StainBox

Blood Slide Stainer

Corporate