Automatic Span Gas Unit Transferstandard

The portable calibration unit ASGU-370TS is designed for the dynamic and continual manufacture of zero and span gas to perform all ongoing quality control procedures according EN Norms. To prepare various span gas concentrations the unit uses technologies like dilution, permeation, Gas Phase Titration.

 

Division: Ambient
Manufacturing Company: HORIBA (Austria) GmbH
  • Portable one component multipoint calibration system acc. EN 14211 or EN 14212 or EN 14626
  • High accuracy of span gas in cause of usage of factory calibrated digital thermal mass flow controllers in high quality
  • Comfortable operation via big illuminated Touch-Screen-Display
  • Operation via RS232 and Ethernet interface (Bayern Hessen protocol)
  • Delivery scope includes remote software for easy external handling (Ethernet)
  • High flexibility by free definable span points (up to 20)
  • High flexibility by free definable cycles (e.g. Lack of fit)
  • High flexibility by free definable sequences (stringing cycles together)
  • Programmable timer allows time shifted start of calibration process
  • Internal data logger (option) stores raw values from calibration procedure (set value and actual value, status) for reporting with evaluation software (included in scope of delivery)

 

 

Principle

Dilution (incl. built in cylinder), Permeation,  Gas Phase Titration, (Mixed gas dilution)

Application

Quality control in Laboratory
Quality control in field

Stage of extension

Only one channel (module) per unit

Flow regulation

Digital Mass flow Controllers

Span gas repeatability

+/- 1%

Span gas linearity

+/- 2% (minimum flow >20% F.S.)

Permeation system
(NO2, SO2, NH3, H2S, BTX)

PID temperature controller with Pt 100 sensor
Temperature: 50°C
Accuracy ±0,1°C
Indication of actual temperature on display

Zero Air Supply

Internal Zero gas preparation

Operation

Manual (Touch Screen Display)
External via RS232 (Gesytec Protocol)
External via Ethernet (Remote Software)

Battery packFor uninterruptible power supply for approx. 30min purge mode without mains voltage

Power 

230VAC, 50Hz
Power consumption depends on stage of channel

Dimensions

510mm(W) x 310mm(D) x 430mm(H)

Mass

Depends on stage of extension

Air Quality Monitoring
Air Quality Monitoring
HORIBA offers customer oriented tailor-made system solutions with its state-of-the-art analytical technologies and more than 50 years experience in ambient air market. As your true partner in environmental preservation, we deliver air quality monitoring, indoor air quality monitoring , clean room airborne molecular contamination monitoring , quality control and stationary emission monitoring by diluted stack gas monitoring.

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

AP-370 series
AP-370 series

Air Pollution Monitor

AQMS
AQMS

Ambient Air Quality Monitoring System

PX-375
PX-375

PM & 중금속 분석기