Electrode Line Up for Water Quality Meters

Overview

General laboratory application

Protein,
high viscosity application

Precious,
trace amount sample


3-in-1 Electrode
9611-10D


3-in-1 Sleeve Electrode
9677-10D


3-in-1 Micro Electrode
9669-10D

Tap water,
pure water application

Non-glass electrode for food application, etc.


3-in-1 Plastic Electrode
9621-10D


ISFET Electrode
0030-10D

Features

ToupH electrode just got ToupHer!

  • Enhanced durability of the glass membrane makes it four times stronger than the conventional ToupH electrode.
  • The patented silver ion trap technology improves response time. The response time is 40 times faster than the conventional electrodes.

    Reference electrode response time over 3 months (tap water).

  • With enhanced durability, the electrode is more easily maintained with a sponge or optional cleaning reagent.


Manufactured by HORIBA Advanced Techno

Specifications

• pH Electrode Line up

Combination electrode (3-in-1 electrode)

Model

Description

Temp.range
(°C)

pH range

Part No.

9611-10D

Waterproof thick membrane type

0 ~ 80

0 ~ 14

9096001800

9677-10D

Protein, high viscosity type

0 ~ 60

0 ~ 14

9096002000

9678-10D

Thick Membrane Electrode

0 ~ 100

0 ~ 14

9003018000

9669-10D

Precious, trace amount sample type

0 ~ 60

0 ~ 14

9096001900

9621-10D

Plastic body

0 ~ 100 *2

0 ~ 14

9096001700

6366-10D

Standard type(ceramic)

0 ~ 100

0 ~ 14

9003011700

6367-10D

Sleeve *1

0 ~ 60

0 ~ 14

9003011800

6377-10D

For Low-conductivity water and non-aqueous solvents

0 ~ 60

0 ~ 14

9003014100

6378-10D

For test tubes *1

0 ~ 60

0 ~ 14

9003011900

6252-10D

For food analysis *1

0 ~ 60

0 ~ 12

9003013800

*1 Do not use this electrode with other electrodes, as it will interfere the measurement value.
*2 0-50°C when completely immersed.

Glass electrode

Model

Description

Temp.range
(°C)

pH range

Part No.

1066A-10C

Standard type

0 ~ 100

0 ~ 14

9003012200

1076A-10C

For Low-conductivity water and non-aqueous solvents

0 ~ 100

0 ~ 14

9003014200

6961-15C

Small sample amount flow type

0 ~ 50

0 ~ 12

9003012400

Reference electrode

Model

Description

Temp.range
(°C)

pH range

Part No.

2060A-10T

Standard type

0 ~ 100

-

9003012500

2660A-10T

Sleeve type

0 ~ 100

-

9003012600

2565A-10T

Double-junction type

0 ~ 100

-

9003012700

Combination electrode

Model

Description

Temp.range
(°C)

pH range

Part No.

6066-10C

Standard

0 ~ 100

0 ~ 14

9003013400

6069-10C

For extra-thin test tubes

0 ~ 60

0 ~ 14

9003013500

6069MP-10C

ø3mm slim electrode

0 ~ 60

0 ~ 14

9003017900

6251-10C

Needle type

0 ~ 50

0 ~ 12

9003013600

6261-10C

Flat type

0 ~ 50

0 ~ 12

9003013700

ISFET electrode

Model

Description

Temp.range
(°C)

pH range

Part No.

0030-10D

Needle type ISFET

0 ~ 60

0 ~ 14

9096002100

ORP electrode

Model

Description

Temp.range
(°C)

pH range

Part No.

6861-10C

Platinum combination type

0 ~ 60

-

9003013100

3060-10C

Platinum single polarity type

0 ~ 60

-

9003013300

9300-10D

Platinum 3-in-1 type

0 ~ 60

-

9096000400

ISFET electrode

Model

Description

Temp.range
(°C)

pH range

Part No.

4163-10T

For temperature compensation and measurement

0 ~ 100

-

9003013000

• Conductivity Electrode Line up

Immersion type

Cell constant m-1(cm-1)

Model

Range m-1(cm-1)

Samples req'd(ml)

Temp.range
(°C)

Part No.

10 (0.1)

3551-10D

10mS ~ 1S
(0.1mS ~ 10mS)

50

0 ~ 60

9056000800

100 (1)

9382-10D

0.1mS ~ 10S
(1mS ~ 100mS)

20 ~ 30

0 ~ 80

9096000300

100 (1)

3552-10D

0.1mS ~ 10S
(1mS ~ 100mS)

15

0 ~ 100

9056000900

1000 (10)

3553-10D

1mS ~ 100S
(10mS ~ 1S)

50

0 ~ 60

9056001000

Flow type

Cell constant m-1(cm-1)

Model

Range m-1(cm-1)

Samples req'd(ml)

Temp.range
(°C)

Part No.

10 (0.1)

3561-10D

10mS ~ 1S
(0.1mS ~ 10mS)

10

0 ~ 60

9056001100

100 (1)

3562-10D

0.1mS ~ 10S
(1mS ~ 100mS)

16

0 ~ 60

9056001200

1000 (10)

3573-10C

1mS ~ 100S
(10mS ~ 1S)

4

0 ~ 60

9056001300

1000 (10)

3574-10C

1mS ~ 10S
(10mS ~ 100mS)

0.25

0 ~ 60

9056001400

• Ion Electrode Line up

Please be aware of the hindering ion and pH range interference of ion electrodes.

Electrode name

Model

Measuring range

Applicable reference electrode

Part No.

Cyanide ion electrode

8001-10C

0.03 ~ 2,600 ppmCN-

2060A•2565A

9003015500

Chloride ion electrode
(Combination type) *

6560-10C

0.4 ~ 35,000 ppmCI-

-

9003014500

Chloride ion electrode

8002-10C

0.4 ~ 35,000 ppmCI-

2565A

9003015600

Sulfide ion electrode

8003-10C

0.3 ~ 32,000 ppmS2-

2060A•2565A

9003015700

Iodide ion electrode

8004-10C

0.01 ~ 13,000 ppmI-

2060A•2565A

9003015800

Bromide ion electrode

8005-10C

0.8 ~ 80,000 ppmBr-

2565A

9003015900

Copper ion electrode

8006-10C

0.06 ~ 6,400 ppmCu2+

2565A

9003016000

Cadmium ion electrode

8007-10C

0.1 ~ 11,000 ppmCd2+

2060A•2565A

9003016100

Lead ion electrode

8008-10C

2 ~ 20,000 ppmPb2+

2565A

9003016200

Thiocyanate ion electrode

8009-10C

0.6 ~ 5,800 ppmSCN-

2565A

9003016300

Fluoride ion electrode
(Combination type) *

6561-10C

0.02 ~ 19,000 ppmF-

-

9003014600

Fluoride ion electrode

8010-10C

0.02 ~ 19,000 ppmF-

2060A•2565A

9003016400

Silver ion electrode

8011-10C

0.01 ~ 110,000 ppmAg+

2565A

9003016500

Ammonia electrode
(Combination type) *

5002A-10C

0.1 ~ 1,000 ppmNH3

-

9003016600

Sodium ion electrode

1512A-10C

2.3 ~ 230,000 ppmNa+

2565A

9003016700

Nitrate ion electrode
(Combination type) *

6581-10C

0.62 ~ 62,000 ppmNO3-

-

9003014700

Nitrate ion electrode

8201-10C

0.62 ~ 62,000 ppmNO3-

2565A

9003016800

Potassium ion electrode
(Combination type) *

6582-10C

0.04 ~ 39,000 ppmK+

-

9003014800

Potassium ion electrode

8202-10C

0.04 ~ 39,000 ppmK+

2565A

9003016900

Calcium ion electrode
(Combination type) *

6583-10C

0.4 ~ 40,080 ppmCa2+

-

9003014900

Calcium ion electrode

8203-10C

0.4 ~ 40,080 ppmCa2+

2060A•2565A

9003017000

Chloride ion chip

7660

-

-

9003015000

Fluoride ion chip

7661

-

-

9003015100

Nitrate ion chip

7681

-

-

9003015200

Potassium ion chip

7682

-

-

9003015300

Calcium ion chip

7683

-

-

9003015400

Ammonia electrode
membrane (6pcs)

membrane(NH3)

-

-

9012001000

* Only combination type ion electrode can be used with the D-23.

• DO electrode / DO Tip Line up

Electrode

Lead length

Model

Specification

Temp.range
(°C)

Part No.

Waterproof DO electrode

2m

9551-20D

Field immersible type

0 ~ 40

9096002300

Waterproof DO electrode

10m

9551-100D

Field immersible type

0 ~ 40

9096002400

DO electrode

1m

9520-10D

Laboratory use

0 ~ 45

9096000500

DO Tip

-

5401

Replacement electrode Tip for 9551

-

9033010000

DO Tip

-

7541

Replacement electrode Tip for 9520

-

9074000200