Bench Meters


Touch panel realizes stress-free operation.
Intuitive, and very easy to use.
We’ve used our unrivalled experience together with detailed feedback from hundreds of customers to develop LAQUA, our most outstanding range of laboratory meters yet.
The HORIBA LAQUA series marries advanced technology with stylish design and an easy-to-use touch screen interface. The LAQUA series was developed as a durable meters offering long term reliability for laboratory professionals. Advanced functionalities and a wide array of electrodes provide high precision measurement with improved response time in a huge variety of applications.
LAQUA PC1100
Overview
Features
- Dual channel / display
- Automatic pH calibration up to 5 points using NIST, USA, or custom pH buffers
- Switchable pH resolution - 0.1, 0.01, 0.001 pH
- Offset and slope display
- Automatic / manual temperature compensation
- Temperature calibration function
- Automatic / manual conductivity calibration up to 4 points
- Adjustable reference temperature and temperature coefficient
- Selectable cell constant and measurement unit
- Resistivity, total dissolved solids (TDS), and salinity conversions from conductivity
- Four TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl
- Two salinity calibration curves: NaCl, Seawater
- Auto log data
- Built-in memory can store up to 999 data
- Real-time clock
- Date / time stamp
- Auto shut-off (programmable: 1 to 30 minutes)
- Auto-Hold / Auto-Stable measurement
- Calibration alarm (programmable: 1 to 400 days)
- Custom black and white static LCD
- RS232C and USB output for connecting the meter to a compatible printer or computer
- Meter password setting
- 2 years meter warranty
Meter Kits Available
PC1100-S
Package Details:
- LAQUA PC1100 Dual channel pH/ORP/EC/Res/TDS/Sal/Temp custom black and white static LCD meter
- 9615S-10D ToupH glass-body, refillable pH electrode with integrated temperature sensor
- 9382-10D plastic-body, titanium/platinum black, conductivity probe (k=1.0) with integrated temperature sensor
- 502-S USA pH buffers: 4.0, 7.00, 10.01 pH buffers & 3.33 M KCl (250ml each)
- 503-S Conductivity standards: 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm (250ml each)
- Data acquisition software in USB flash drive (communication cable is sold separately)
- Integrated electrode stand
- Protection cover
- Power adaptor with 6 plugs (US, EU, UK, Australia / New Zealand, China, Korea)
- Instruction manual
PC1100-SN
- Meter kit with 501-S NIST pH buffers: 4.01, 6.86, 9.18 pH buffers & 3.33 M KCl, 250ml each (in place of 502-S USA pH buffers)
Manufactured by HORIBA Advanced Techno
Specifications
Model | LAQUA PC1100 Dual Channel pH/ORP/EC/Res/TDS/Sal/Temp (°C) |
---|---|
pH Range | -2.000 to 20.000 pH |
Resolution | 0.1 / 0.01 / 0.001 pH |
Accuracy | ± 0.003 pH |
Calibration Points | Up to 5 |
Buffer Options | USA / NIST / Custom |
ORP Range | ± 2000 mV |
Resolution | 0.1 mV |
Accuracy | ± 0.2 mV |
Conductivity (EC) Range | 0.000 µS/cm to 20.00 mS/cm (k=0.1) 0.00 µS/cm to 200.0 mS/cm (k=1) 0.0 µS/cm to 2.000 S/cm (k=10) |
Resolution | 0.05% of full scale |
Accuracy | ± 0.6% of full scale; ± 1.5% of full scale > 18.0 mS/cm |
Reference Temperature | 15 to 30 °C (Adjustable) |
Temperature Coefficient | 0.00 to 10.00 % (Adjustable) |
Cell Constant | 0.1 / 1.0 / 10.0 (Selectable) |
Measurement Unit | μS/cm, mS/cm, S/m (Auto-ranging / Manual) |
Calibration Points | Up to 4 (Auto / Manual) |
TDS Range | 0.00 mg/L to 100 g/L |
Resolution | 0.01 mg/L |
Accuracy | ± 0.1% of full scale |
Calibration Curves | EN27888 / 442 / Linear (0.40 to 1.00) / NaCl |
Resistivity Range | 0.0 Ω•cm to 2.000 MΩ•cm (k=10) 0.000 kΩ•cm to 20.00 MΩ•cm (k=1) 0.00 kΩ•cm to 200.0 MΩ•cm (k=0.1) |
Resolution | 0.05% of full scale |
Accuracy | ± 0.6% of full scale; ± 1.5% of full scale > 1.80 MΩ•cm |
Salinity Range | 0.00 to 100.00 ppt / 0.000 to 10.000 % |
Resolution | 0.01 ppt / 0.001 % |
Accuracy | ± 0.2% of full scale |
Calibration Curves | NaCl / Seawater |
Temperature Range | -30.0 to 130.0 °C |
Resolution | 0.1 °C |
Accuracy | ± 0.4 °C |
Calibration Option | Yes |
Memory Data | 999 |
Auto Log Data | Yes |
Real-time Clock | Yes |
Date / Time Stamp | Yes |
Auto-Shut Off | Yes (Programmable: 1 to 30 minutes) |
Auto-Hold / Auto-Stable | Yes |
Offset / Slope Display | Yes (Independent acid and alkaline slopes depending on calibration) |
Electrode Status | On screen display |
Diagnostic Messages | Yes |
Calibration Alarm | Yes (Programmable: 1 to 400 days) |
Display | Custom black and white static LCD, Dual Channel |
Inputs | Dual BNC, dual phono, DC sockets |
Output | RS232C, USB |
Power Requirement | AC adaptor, 100-240V, 50/60Hz |
Weight | 500g |
Dimensions | 170(L) x 174(D) x 73(H) mm |
HORIBA Offices
Asia & Oceania
Singapore
HORIBA Instruments (Singapore) Pte Ltd.
work
83 Science Park Drive, #02-02A,
The Curie 118258 Singapore
work
+65 6 908 9660
work
fax
+65 6 745 8155
laqua@horiba.com
Europe, Middle East & Africa
Northampton
HORIBA UK Limited
Northampton Office
work
Kyoto Close,Summerhouse Road,
Moulton Park
Northampton NN3 6FL UK
Moulton Park
work
+(44) 1604 542 600
work
fax
+(44) 1604 542 699
waterquality@horiba.com