Menu

 In the lab, in the field or anywhere you need it


On top of using a double moulding injection process integrating polycarbonate resin and TPE to create an eco-friendly, shock & scratch resistant, non-slip body, several improvements and enhancements have been made to the latest HORIBA LAQUA handheld meters allowing sustained periods of operations in challenging outdoor conditions and making the 200 series a compact yet powerful versatile meter.

LAQUAact PD110

Overview

pH mV(ORP) DO, Dissolved Oxygen   
Waterproof and dustproof (IP67 rated) Shock and chemical resistant body case Back light LCD PC PRT 2CH

Features

  • Dual channel, switchable display
  • Automatic pH calibration up to 5 points using NIST, USA, or Custom pH buffers
  • 0.01 pH resolution
  • Offset and slope display 
  • Automatic / Manual temperature compensation and temperature calibration function
  • Measures dissolved oxygen (DO) concentration in ppm (mg/L) or % saturation
  • 0.01 mg/L or 0.1% DO resolution
  • Compensates for sample salinity and temperature and atmospheric pressure 
  • Up to 2 DO calibration points 
  • Auto log data; Built-in memory can store up to 1000 data
  • Auto-shut off (programmable: 1 to 30 minutes)
  • Auto-Hold / Auto-Stable measurement
  • Caibration alarm (programmable: 1 to 400 days)
  • Built-in electrode holder allows 2 electrodes to be attached on both sides of the meter
  • Large backlit LCD: 52mm x 64mm
  • RS232 output for connecting to computer or printer
  • Casing is IP67 waterproof (for 30mins immersion in 1m depth of water) and dustproof
  • Powered by 2 x AAA (LR03) or Ni-MH rechargeable batteries or power adaptor
  • Packaged in new molded carry case
  • 2 years meter warranty

Meter Kit Available 

PD110-K

  

The appearance of items in the picture are subject to change in each region.

Package Details:

  • LAQUAact PD110 Dual Channel pH/ORP/DO/Temp meter, built-in electrode holder, 2 x AAA batteries
  • Instruction manual
  • 9651-10D plastic-body, gel-filled pH electrode with integrated temperature sensor
  • 9551-20D Galvanic DO probe with integrated temperature sensor, 2m cable
  • pH 4.01 / 7.00 / 10.01 buffers (60ml each)
  • Carry case

PD110-KN: Kit with pH 4.01 / 6.86 / 9.18 NIST buffers (60ml each) is available upon request. 

 


Manufactured by HORIBA Advanced Techno

Specifications

Model

LAQUAact PD110

Dual Channel pH/ORP/DO/Temperature

pH Range

-2.00 to 16.00 pH

Resolution

0.01 pH

Accuracy

± 0.01 pH

Calibration Points

Up to 5

Buffer Options

USA, NIST, Custom

ORP Range

± 2000 mV

Resolution

1 mV

Accuracy

± 1mV or 1% of reading (whichever is greater)

DO Range

0.00 to 20.00 mg/L / 0.0 to 200.0 %

Resolution

0.01 mg/L or 0.1 %

Accuracy

±0.1 mg/L

Salinity Compensation

0 to 40 ppt

Barometric Pressure Compensation

Yes

Temperature Compensation

Yes

Calibration Points

Up to 2

DO Probe

Galvanic

Temperature Range

-30.0 to 130.0°C

Resolution

0.1°C

Accuracy

± 0.4°C

Calibration Option

Yes

Memory Data

1000

Auto Log Data

Yes

Real-time Clock

Yes

Date / Time Stamp

Yes

Auto-Shut Off

Yes (Programmable: 1 to 30 minutes)

Auto-Hold / Auto-Stable

Yes

Offset / Slope Display

Yes (Independent acid and alkaline slopes depending on calibration)

Calibration Alarm

Yes (Programmable: 1 to 400 days)

Electrode Status

On screen display

Diagnostic Messages

Yes

Display

Custom Backlit LCD / Dual Channel / Switchable Display 

Inputs

2 x BNC, 2 x phono, DC sockets

Output

RS232

IP Rating

IP67, shock-resistant

Power Requirements

2 x AAA (LR03) or Ni-MH rechargeable batteries or power adaptor

Battery Life

>500 hours

HORIBA Offices

Asia & Oceania

Europe, Middle East & Africa

Northampton

HORIBA UK Limited Northampton Office
work
Kyoto Close,Summerhouse Road,
Moulton Park
Northampton NN3 6FL UK
work +(44) 1604 542 600
work fax +(44) 1604 542 699

Americas

Irvine, California

HORIBA Instruments Incorporated Head Office
work
9755 Research Drive
Irvine California 92618 USA
work +1 800 446 7422
work fax +1 949 468 1790