MEXA-2000SPCS series

MEXA-2000SPCS - Solid Particle Counting System
MEXA-2000SPCS - Engine Vehicle Certification Testing
MEXA-2000SPCS - Partial Flow Dilution Tunnel

Solid Particle Counting System

The HORIBA MEXA-2000SPCS series measures the number of solid particles from engine exhaust gas in real-time.
The series can complete engine/vehicle certification testing in the latest regulations*1, such as Euro 6/VI and China 6/VI,along with R&D testing of engines and particulate filters by direct sampling without dilution.

*1: Please contact us for more information on the regulations that the products comply with.

Segment: Automotive
Firma produkcyjna : HORIBA, Ltd.

Line-ups

  • Certification tests for the latest regulations
    MEXA-2000 / 2200SPCS
  • R&D tests with high pressure direct sampling  
    MEXA-2100 / 2300SPCS
  • SPN10 particle measurement [New Lineup]  
    (Fulfills GTR No.15, Amendment 6, SPN 10 requirements)  
    MEXA-2010/2110/2210/2310SPCS

 

Sampling methods
ModelsMEXA-2000SPCS
MEXA-2010SPCS
MEXA-210SPCS
MEXA-2110SPCS
MEXA-2200SPCS
MEXA-2210SPCS
MEXA-2300SPCS
MEXA-2310SPCS
Sampling methodFull Flow TunnelFull Flow Tunnel
Direct Sampling
Full Flow Tunnel
Partial Flow Tunnel
Full Flow Tunnel
Direct Sampling
Partial Flow Tunnel

Features

  • Compact design

• Easy to install and transport in a laboratory
• Small footprint 

        
     
       
 
  • High performance sampling system

The set DF is not affected by changes in sample pressure in the CVS or
sampling system. The VPR *1 calibration factor (PCRF *2) can be used
for many applications without specific calibration/correction of the diluters
in VPR.
*1 VPR: Volatile Particle Remover
*2 PCRF: Particle Concentration Reduction Factor

  • Various optional units

The combination of the main unit and optional units allows a wide range of applications and sampling configurations.

 For Measurement
Optional UnitsFunctions2000210022002300
Cyclone Unit (CYU) *1External CycloneBuilt-inBuilt-in
Sample Return Unit (SRU)Returning sample to CVS×××
Cooler Unit (CLU) *2Cooling detector (CPC) for high temperature conditions

For Performance Check
Optional UnitsFunctions2000210022002300
Dilution Factor Checker (DFC)Dilution factor check and flow rate calibration
Linearity Check Unit (LCU)Generating solid particles for linearity check
and penetration efficiency check
Volatile-particle Generation Unit (VGU)Generating particles for removal efficiency
check of evaporation tube

*1: For MEXA-2000/2200SPCS, select a hatted probe or an external cyclone unit set at full flow tunnel side.
*2: Mounted in an optional 19-inch cabinet with main unit.

  • High accuracy dilution

Reliable diluter developed by HORIBA Group
  Patent number: 7201071(US)

  • Dedicated particle number counting

Fully integrated system for stand-alone operation with the comprehensive
data logging functions. Also available for operation with host CPU control
using the AK-LAN host interface.

ModelsMEXA-2000SPCSMEXA-2100SPCSMEXA-2200SPCSMEXA-2300SPCS
Complying Regulations*1GTR No.15,
Amendment 6
Euro 6, Euro VI,
Stage V (NRMM),
China 6, China VI,
Bharat Stage VI (LDV/HDV)
-GTR No.15,
Amendment 6
Euro 6, Euro VI,
Stage V (NRMM),
China 6, China VI,
Bharat Stage VI (LDV/HDV)
-*2
Measuring principleLaser scattering condensation particle counting (CPC)
Lower particle size limitCounting efficiency of 23 nm particles: 50 % ±12 %, Counting efficiency of 41 nm particles: >90 %
Measuring components and rangeNumber concentration of solid particles; 0 – 10000 up to 0 – 50000 particles/cm3 (after internal dilution) *3
Sample handling temperature52 °C or less (Dilute sampling)Maximum permissive temperature
(Direct sampling) 350 °C *4
52 °C or less (Dilute sampling)Maximum permissive temperature
(Direct sampling) 350 °C *4 
Diluted sample temperaturePrimary diluter (PND1):
191 °C ± 10 °C
Evaporation tube (ET):
350 °C ± 10 °C
Secondary diluter (PND2):
< 35 °C (at inlet of CPC)
Pre-classifier: 47 °C ± 5 °C
Primary diluter (PND1):
191 °C ± 10 °C
Evaporation tube (ET):
350 °C ± 10 °C
Secondary diluter (PND2):
< 35 °C (at inlet of CPC)
Primary diluter (PND1):
191 °C ± 10 °C
Evaporation tube (ET):
350 °C ± 10 °C
Secondary diluter (PND2):
< 35 °C (at inlet of CPC)
Pre-classifier: 47 °C ± 5 °C
Primary diluter (PND1):
191 °C ± 10 °C
Evaporation tube (ET):
350 °C ± 10 °C
Secondary diluter (PND2):
< 35 °C (at inlet of CPC)
Dilution factors in diluters Primary diluter (PND1):
10 to 200 *3
Secondary diluter (PND2): 15
Diluter in DSU: 10
Primary diluter (PND1):
10 to 200 *3
Secondary diluter (PND2): 15
Primary diluter (PND1):
10 to 200 *3
Secondary diluter (PND2): 15
Diluter in DSU: 10
Primary diluter (PND1):
10 to 200 *3
Secondary diluter (PND2): 15
PCRF0.95 < fr (30 nm) / fr (100 nm) < 1.3, 0.95 < fr (50 nm) / fr (100 nm) < 1.2
Volatile particle removal efficiency>99.0%, for C40 (30 nm of particle size, and 10000 particles/cm3 or more)
Accuracy of dilution factorWithin ± 10 % of nominal dilution factor setting (for VPR total dilution factor of 150 to 3000, gas based) *5
Operating environmentWithout CLU (standard): Ambient temperature: 5 °C to 30 °C, Ambient humidity: 80 % or less as relative humidity
With CLU (optional): Ambient temperature: 5 °C to 45 °C, Ambient humidity: 80 % or less as relative humidity
Power supply voltage and frequency200/220/230/240 V AC (±10 %, max. 250 V), 50/60Hz (±1.0 Hz), single phase (to be specified at ordering)
Power requirementsMain unit: Max. 2.3 kVA
Main unit and all optional units: Max. 4.5 kVA
Main unit: Max. 2.5 kVA
Main unit and all optional units: Max. 4.4 kVA
Main unit: Max. 2.4 kVA
Main unit and all optional units: Max. 4.3 kVA
Main unit: Max. 2.6 kVA
Main unit and all optional units: Max. 4.5 kVA
Dimensions (excluding any projections) /Mass  
Main unit
(without transfer tube, control unit and optional units)
434(W)×731(D)×637(H) mm
Approx. 115 kg
434(W)×845(D)×637(H) mm
Approx. 120 kg
434(W)×910(D)×637(H) mm
Approx. 140kg
434(W)×910(D)×637(H) mm
Approx. 145 kg
Optional units                                        CYU: Approx. 290(W)×146(D)× 236(H) mm *6 Approx. 4 kg
                                        SRU: Approx. 300(W)×550(D)× 450(H) mm Approx. 35 kg
                                        CLU: Approx. 570(W)×850(D)×1227(H) mm Approx. 80 kg (for CLU and optional cabinet)
                                        DFC: Approx. 464(W)×550(D)× 320(H) mm Approx. 38 kg
                                        LCU: Approx. 350(W)×690(D)× 670(H) mm Approx. 35 kg
                                        VGU: Approx. 550(W)×300(D)× 450(H) mm Approx. 20 kg 


*1: Please contact us for more information on the regulations that the products comply with.
*2: MEXA-2300SPCS can be used in the measurement method according to the regulation. For detailed information, please contact HORIBA.
*3: Dilution factor of the system should be determined so that the particle concentration after dilution fits into the measuring range.
*4: Allowable range of gas temperature at sample probe inlet depends on the sampling condition, because it is limited as the temperature of diluter in DSU (350 °C or less). For detailed information, please contact HORIBA.
*5: Accuracy of dilution factor check with span gas.
*6: The dimensions depend on customers.

Brake Dust Measurement
Brake Dust Measurement
A series of legislative measures has significantly reduced the amount of emissions that is being emitted by internal combustion engines of light and medium-duty vehicles.
Particle Measurement in the Sub-23nm Range
Particle Measurement in the Sub-23nm Range
Concerns exist that advances in modern engine technology may contribute to large portions of solid particles at sizes smaller than 23nm. The EU Joint Research Center has confirmed this concern in several investigations.

Wniosek o udzielenie informacji

Masz pytania lub prośby? Skorzystaj z tego formularza, aby skontaktować się z naszymi specjalistami.

* Te pola są obowiązkowe.

Related products

CVS-ONE
CVS-ONE

Constant Volume Sampler

EXFM-ONE
EXFM-ONE

Ultrasonic Exhaust Flow Meter

FTX-ONE-CL
FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

GIANT 5200
GIANT 5200

Brake Dynamometer for Brake Emissions Testing

GIANT 6000 Series
GIANT 6000 Series

Multi-Purpose Brake Dynamometers

MDLT-ONE
MDLT-ONE

Micro Dilution Tunnel

MEDAS
MEDAS

Dynamic Altitude Simulation

MEDAS Humidity Module
MEDAS Humidity Module

Altitude Simulator

MEDAS Temperature Module
MEDAS Temperature Module

Altitude Simulation

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-730λ
MEXA-730λ

Air-to-fuel Ratio Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE PM unit
OBS-ONE PM unit

On-board Emissions Measurement System

OBS-ONE PN Unit
OBS-ONE PN Unit

On-board Emissions Measurement System

OBS-ONE SPN10 Unit
OBS-ONE SPN10 Unit

On-board SPN10 measurement for real-world

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

PFS-ONE
PFS-ONE

Particulate Filter Management System

PTFM-1000V2
PTFM-1000V2

Pitot Tube Exhaust Flow Meter

PTFM-ONE-DT
PTFM-ONE-DT

Dual Pitot Tube Exhaust Flow Meter

Torque Matching
Torque Matching

Road-to-Rig Chassis Dyno Replication

AP-370 Series
AP-370 Series

Air Pollution Monitor

APDA-372
APDA-372

Ambient Dust Monitor

AQMS
AQMS

Ambient Air Quality Monitoring System

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

MESA-50
MESA-50

X-Ray Fluorescence Analyzer

MESA-50K
MESA-50K

X-Ray Fluorescence Analyzer

OBS-ONE PM unit
OBS-ONE PM unit

On-board Emissions Measurement System

TFH-01/47
TFH-01/47

PTFE Filter/TFH membrane

XGT-9000
XGT-9000

X-ray Analytical Microscope (Micro-XRF)

XGT-9000SL
XGT-9000SL

X-ray Analytical Microscope
with a Super Large Chamber

OBS-ONE PN Unit
OBS-ONE PN Unit

On-board Emissions Measurement System

OBS-ONE SPN10 Unit
OBS-ONE SPN10 Unit

On-board SPN10 measurement for real-world

Water & Liquid Corporate