XGT-9000SL

X-ray Analytical Microscope
with a Super Large Chamber

Ultimate experience in microscopic analysis on large samples without compromising safety.

  • Large chamber capacity: 1030 mm x 950 mm x 500 mm [W x D x H]
  • Large area mapping: up to 350 mm x 350 mm
  • Full protection from X-ray exposure (IEC61010-1 / JAIMAS0101-2001 compliant)
  • <15 µm spot size with an ultra-high intensity probe without compromising sensitivity and spatial resolution
  • Dual types of detectors for fluorescent X-rays and transmission X-rays
  • Detectable element range down to carbon with XGT-9000SL C with optional He purge module
Segment: Scientific
Firma produkcyjna : HORIBA, Ltd.

Designed to revolutionize large sample analysis and expand your applications

The XGT-9000SL series has a super large chamber capacity up to 1030 mm x 950 mm x 500 mm [W x D x H] and includes a wide stage by 500 mm x 500 mm. The features enable users to analyze even sizable samples such as paintings, large printed circuit boards, and brake rotors. It is perfect for handling such large samples with ease and carried out elemental analysis on it non-destructively. It is also versatile to accommodate multiple small sized samples on the stage to carry out sequential analysis.

 


Dual types of detectors for fluorescent X-rays and transmission X-rays

The XGT-9000SL Series provides dual types of detectors. One is a fluorescent X-ray detector which tells the elemental distribution of a sample, and the other is a transmission X-ray detector which tells the internal structure of a sample. XGT-9000SL can get the two types of images of the same area simultaneously. Especially it is helpful for a better understanding of electronics, gemstones including inclusions, and biological specimens.

Simultaneous imaging of elemental image and transmission X-ray image of a printed circuit board
(Left) Elemental layered image revealed a foreign matter stuck under the IC chip. (Right) Transmission X-ray image revealed many voids under the IC chip.

 


Protect users from X-ray exposure with the X-ray shield chamber

The XGT-9000SL is designed with highest level of X-ray shielding against X-ray radiations (IEC-61010-1 / JAIMAS0101-2001 compliant). With its 1) transparent shield, users can easily observe and monitor the sample in the chamber during a measurement without compromising user safety. The system also includes 2) an X-ray irradiation indicator located on the front panel alerting users when X-rays are active. Furthermore, the XGT-9000SL is equipped with 3) interlocks on the chambers doors, preventing any X-ray irradiation in the unlikely event that an user accidentally opens the door while the system is in operation.

 


Multiple safety functions protect your precious samples from collision risks

Multiple safety functions are incorporated to ensure the protection of your precious samples:

  1. Stage position calculation: The software can calculate the safe initial position based on an input value of a sample height. This means that the stage will move up and stop at the optimal position, minimizing the risk of accidental collisions with the optics or other sensitive components.
  2. Laser sensor: The system can detect interference from your samples with a laser sensor and stop the stage before your sample contacts with the optics even if an inaccurate sample height has been input.
  3. Stage lock: The XGT-9000SL Series comes equipped with a sophisticated stage controller that incorporates a safety stage lock function. Even if an user accidentally operates the stage in a wrong way, the stage will not go beyond the designated safe position.

 


Flexible and user-friendly software

The XGT-9000SL Series software has a highly flexible and user-friendly interface. It displays data trees, optical images, spectrum results, the periodic table, and map imaging results at a glance. Users also have the flexibility to customize the on-screen layout, or even to show the results on multiple monitors. Thus, it allows users to see the results more clearly and boosts your data analysis.

Apart from the standard software functions, the advanced modules can be added to the software suite to provide more comprehensive user experiences.

  • Multilayer FPM module: for thickness measurement with/without standard samples
  • RoHS module: for RoHS screening
  • Queue module: for automated multiple measurements in unattended mode
  • Particle Finding module: for particle analysis and co localized analysis
  • LabSpec Link module: for data transfer to LabSpec 6 for multivariate analysis

 



Application  Examples


Model
XGT-9000SL
XGT-9000SL ProXGT-9000SL C


Basic information

   Instrument

X-ray analytical microscope with a super large chamber
   PrincipleEnergy dispersive X-ray fluorescence spectroscopy
   Detectable elementsF (9)* - Am (95)C (6)* - Am (95)
   Available chamber size1030 mm (W) x 950 mm (D) x 500 mm (H)
   Maximum stage loading capacity10 kg
   Maximum mapping area350 mm x 350 mm on 500 mm x 500 mm


Sample observation

   Optical image observationTwo high resolution cameras
   Whole image
   Detailed image
5 million pixels, Field of view: 350 mm x 350 mm
5 million pixels, Field of view: 2.5 mm x 2.5 mm
   Optical designVertical-coaxial X-ray and optical observation
   Sample illumination / ObservationTop, bottom, side illuminations / Bright and dark fields


X-ray generator

   PowerUp to 50 W
   VoltageUp to 50 kV
   CurrentUp to 1 mA
   Target materialRh


X-ray guide tube (Probe)

   Probe spot size selectionVarious probe combination can be offered
(e.g. 15 μm ultra-high intensity probe and 100 μm ultra-high intensity probe can be chosen)


Detectors

   X-ray fluorescence detectorLiquid nitrogen-free Silicon Drift Detector (SDD)
   Transmission detectorNaI (Tl)


Operating mode

   Measurement environmentPartial vacuum
Whole ambient
He purge (optional)*
Partial vacuum
Whole ambient
He purge (optional)*


Instrument dimention (main unit)

   Instrument size1090 mm (W) x 1380 mm (D) x 1820 mm (H)
   Mass weightApproximately 550 kg

*He purge condition is necessary to detect down to fluorine with XGT-9000SL Pro or down to carbon with XGT-9000SL C.

Pigment analysis on an antique paper painting by micro-XRF with a super large chamber
Pigment analysis on an antique paper painting by micro-XRF with a super large chamber
Identification of pigments is important in the archaeological and art research fields. Some pigments were used during specific times and then were no longer used in later times. Therefore, we can estimate the period when artwork was created through identification of the pigments. Micro-XRF is an effective pre-screening analytical technique to narrow down the candidates of multiple pigments used on a painting, thanks to its non-destructive approach and imaging capability.
Non-destructive large area elemental map imaging on the painting “Flower Vase with Thistles” using the XGT-9000SL
Non-destructive large area elemental map imaging on the painting “Flower Vase with Thistles” using the XGT-9000SL
Pigments are important clues to the historical background of artworks. This application note introduces elemental map imaging performed on Vincent van Gogh’s oil painting “Flower Vase with Thistles” using the XGT-9000SL. The results reveal that elemental compositions of the pigments used on the painting were different from ones previously reported to have been used by van Gogh. It suggests that this painting was a replica of the artwork.
Non-destructive failure analysis of a commercial PEMFC using a micro-XRF with a super large chamber
Non-destructive failure analysis of a commercial PEMFC using a micro-XRF with a super large chamber
We introduce non-destructive failure analysis on a large membrane electrode assembly (MEA) from a commercial PEMFC stack using a HORIBA XGT-9000SL, a micro-XRF with an extra-large chamber capacity. Thanks to the chamber capacity, we successfully performed non-destructive elemental imaging on a defective area without cutting the sample, and we found unexpected distributions of Fe, Ni, Mn and Cr within the defective area, and that the elements are present in the MEA as a result of possible degradation of the bipolar plate.
Metal elusion imaging using micro-XRF to identify the root cause of PEMFC degradation
Metal elusion imaging using micro-XRF to identify the root cause of PEMFC degradation
Proton exchange membrane fuel cells (PEMFCs) are getting more and more popular as a clean energy, and a lot of research is being done to achieve better durability for further spread into more commercial phase.
Applications of micro-XRF for PEMFC catalyst research: Pt catalyst uniformity imaging and Pt loading mass determination
Applications of micro-XRF for PEMFC catalyst research: Pt catalyst uniformity imaging and Pt loading mass determination
The HORIBA micro-XRF system performs two applications for proton exchange membrane fuel cell (PEMFC) catalyst research: One is Pt catalyst uniformity imaging within a catalyst sheet thanks to the imaging capability. The other is Pt catalyst loading mass determination on average, which is a popular application of EDXRF. Through the experiments, we successfully visualized aggregates of Pt catalyst in our samples, and we also got a good linearity of calibration curve for Pt catalyst loading mass determination.
Surface analysis on a brake rotor of automotive tire
Surface analysis on a brake rotor of automotive tire
The XGT-9000SL’s large chamber capacity allows you to put whole a brake rotor and carry out spectrum analysis and elemental distribution imaging on the rotor surface, non-destructively.
Non-destructive failure analysis on a large printed circuit board
Non-destructive failure analysis on a large printed circuit board
Our XGT-9000SL allows failure analysis at a microscopic level on a large sample, non-destructively, thanks to its large chamber capacity and its microprobes.
Non-destructive thickness and composition analysis of NiP/Au plating on Cu contacts using micro-XRF
Non-destructive thickness and composition analysis of NiP/Au plating on Cu contacts using micro-XRF
We carried out plating thickness and composition analysis on dual-layer NiP/Au plating on Cu contacts on a flexible printed circuit using a HORIBA X-ray analytical microscope. We successfully detected Au of ultra-thin layer without any sample preparation. The thickness results of Au and NiP plating were consistent with the provided values and with good repeatability.
Plant science - Inorganic element imaging on a leaf using micro-XRF
Plant science - Inorganic element imaging on a leaf using micro-XRF
A wide range of elements are present in plants. Some elements exist to play important roles as plant nutrients or enzymes, and some elements accumulate unexpectedly due to environmental pollution. While it is important to understand the bulk concentrations of individual elements from a nutritional and ecotoxicological perspective, the distribution of elements is also important for a better understanding of the mechanisms of metabolism and uptake in plants.

Wniosek o udzielenie informacji

Masz pytania lub prośby? Skorzystaj z tego formularza, aby skontaktować się z naszymi specjalistami.

* Te pola są obowiązkowe.

Related products

XGT-9000
XGT-9000

X-ray Analytical Microscope (Micro-XRF)

AP-370 Series
AP-370 Series

Air Pollution Monitor

APDA-372
APDA-372

Ambient Dust Monitor

AQMS
AQMS

Ambient Air Quality Monitoring System

Auto SE
Auto SE

Spectroscopic Ellipsometer for Simple Thin Film Measurement

Auto SE Accessories
Auto SE Accessories

Customize your instrument

Auto Soft
Auto Soft

Intuitive Auto-Soft Interface for the Auto SE and Smart SE

DataOverlay
DataOverlay

Hybrid Chemical and Video Image Display

DeltaPsi2 Software
DeltaPsi2 Software

A Platform for HORIBA Scientific Ellipsometers

GD-Profiler 2™
GD-Profiler 2™

Pulsed-RF Glow Discharge Optical Emission Spectrometer

GDOES Accessories
GDOES Accessories

Accessories for samples with various shapes, sizes and properties

GDOES Software
GDOES Software

Quantum and Image

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

ICP Neo
ICP Neo

ICP Software

ICP-OES
ICP-OES

Complete your ICP-OES Spectrometer for your specific needs

Image Enhancement
Image Enhancement

Emphasize Raman and Optical Images

LabRAM Odyssey Nano
LabRAM Odyssey Nano

AFM-Raman for physical and chemical imaging

LabRAM Soleil
LabRAM Soleil

Raman Spectroscope - Automated Imaging Microscope

LabRAM Soleil Nano
LabRAM Soleil Nano

Real-time and Direct Correlative Nanoscopy

LabSpec 6: Validated performance
LabSpec 6: Validated performance

LabSpec 6 is a validated software

LEM Series
LEM Series

Camera Endpoint Monitor based on Real Time Laser Interferometry

MESA-50
MESA-50

X-Ray Fluorescence Analyzer

MESA-50K
MESA-50K

X-Ray Fluorescence Analyzer

Methods
Methods

Recall settings, and automate processes

MEXA-2000SPCS series
MEXA-2000SPCS series

Solid Particle Counting System

Multivariate Analysis
Multivariate Analysis

Data analysis for complex data sets

OBS-ONE PM unit
OBS-ONE PM unit

On-board Emissions Measurement System

OneClick
OneClick

Fast and easy Raman acquisition

OpenPleX
OpenPleX

Manual label-free molecular interaction analysis machine Flexible Research Platform

Script and ActiveX
Script and ActiveX

Customize with VBS

Smart SE
Smart SE

Powerful and Cost Effective Spectroscopic Ellipsometer

TFH-01/47
TFH-01/47

PTFE Filter/TFH membrane

Ultima Expert
Ultima Expert

High resolution, high sensitivity and high stability ICP-OES

Ultima Expert LT
Ultima Expert LT

Affordable high performance ICP-OES

User Accounts
User Accounts

Password protected user access control

UVISEL Plus
UVISEL Plus

Spectroscopic Ellipsometer from FUV to NIR: 190 to 2100 nm

XGT-9000
XGT-9000

X-ray Analytical Microscope (Micro-XRF)

XploRA Nano
XploRA Nano

AFM-Raman for Physical and Chemical imaging

XploRA™ PLUS
XploRA™ PLUS

MicroRaman Spectrometer - Confocal Raman Microscope

MESA-50
MESA-50

X-Ray Fluorescence Analyzer

MESA-50K
MESA-50K

X-Ray Fluorescence Analyzer

MESA-7220V2
MESA-7220V2

X-ray Fluorescence Sulfur/Chlorine-in-oil Analyzer

SLFA-20
SLFA-20

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-2100/2800
SLFA-2100/2800

X-ray Fluorescence Sulfur-in-Oil Analyzers

SLFA-60
SLFA-60

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-6000
SLFA-6000

X-ray Fluorescence Sulfur-in-Oil Analyzer

X-5000*
X-5000*

Energy Dispersive X-ray Fluorescence Analyzer

XGT-9000
XGT-9000

X-ray Analytical Microscope (Micro-XRF)

Water & Liquid Corporate