ENDA-4000 Stack Gas Analysis System

Overview

As a turn-key CEMS supplier, Horiba accepts total responsibility to ensure that our systems meet all customer and compliance requirements. Horiba offers more than 50 standard versions of the ENDA-4000 series. Each system features an XS analyzer or an XE analyzer, as well as a sample conditioning system. Either analyzer can be combined with a standard sampling system, a flow monitor, and an opacity monitor to provide a flexible, powerful, and totally cost-effective integrated system.

The field-proven sample conditioning system uses a two-stage sample drying technique to deliver clean, dry sample into the analyzers, thus ensuring accurate measurements with minimum loss of gases to be measured. All systems include automatic calibration, calibration gas injected at the probes, and a sample line temperature controller installed in the cabinet. Probe blowback capability is optional.

ENDA-4000 System literature

Features

Measurement up to five gases.

No optical alignment required.

No routine maintenance required.

Highly reliable with technology proven in thousands of installations.

Manufactured under strict ISO 9001 certification.


Manufactured by HORIBA

Specifications

Gases/Range available

Specification Value

NOx(NDIR)

0-100/5000ppm

SO2(NDIR)

0-50/5000ppm

CO(NDIR)

0-50/5000ppm standard or 0-10/1000ppm

NOx(CLD option)

0-10/5000ppm

SO2(UV option)

0-10/5000ppm

CO2

0-5/50%

O2

0-10/25%

Optional Additional Measurements

Flow, Opacity, HCl, NH3, Cl2 and THC

Power consumption

700 VA for standard model. Additional 300VA required for CLD(NOx) or UV(SO2) options.

System output Contacts

Standard: Low sample flow, thermoelectric cooler temperature, sample line temperature, analyzer malfunction, power failuer, maintenance in progress, blowback in progress, and calibration fault and range indication by channel.

Material exposed to sampls gas

304 and 316 stainless steel, TeflonTM, VitonTM, polypropylene, fluororubber, PVC, KynarTM,, and glass

NEMA Rating

NEMA 12 standard, NEMA 4, or NEMA 4X optional

Dimensions;

Height:

Width:

Depth:

 

72 in (1829 mm)

24 in (610 mm)

30 in (762 mm)

Weight

Approx. 440 lb (200kg)

Sample gas condition

Temperature

Dust

NO

NO2

SO2

SO3

CO

CO2

H2O

Others

Standard system designed for the following sample gas conditions;

250°C

0.1 g/Nm3 (0.04 grains/dscf)

1000 ppm (max. 5000ppm)

15 ppm

1000 ppm (max.5000ppm)

50 ppm

500 ppm (max. 5000ppm)

15 vol% (max. 50 vol%)

4 to 20 vol%

Corrosive gases (HF, HCl, Cl2) not present; Options: NH3 scrubber, CH4 compensation