ENDA-4000 Stack Gas Analysis System
Overview
As a turn-key CEMS supplier, Horiba accepts total responsibility to ensure that our systems meet all customer and compliance requirements. Horiba offers more than 50 standard versions of the ENDA-4000 series. Each system features an XS analyzer or an XE analyzer, as well as a sample conditioning system. Either analyzer can be combined with a standard sampling system, a flow monitor, and an opacity monitor to provide a flexible, powerful, and totally cost-effective integrated system.
The field-proven sample conditioning system uses a two-stage sample drying technique to deliver clean, dry sample into the analyzers, thus ensuring accurate measurements with minimum loss of gases to be measured. All systems include automatic calibration, calibration gas injected at the probes, and a sample line temperature controller installed in the cabinet. Probe blowback capability is optional.
Features
Measurement up to five gases.
No optical alignment required.
No routine maintenance required.
Highly reliable with technology proven in thousands of installations.
Manufactured under strict ISO 9001 certification.
Manufactured by HORIBA
Specifications
Gases/Range available | Specification Value |
|---|---|
NOx(NDIR) | 0-100/5000ppm |
SO2(NDIR) | 0-50/5000ppm |
CO(NDIR) | 0-50/5000ppm standard or 0-10/1000ppm |
NOx(CLD option) | 0-10/5000ppm |
SO2(UV option) | 0-10/5000ppm |
CO2 | 0-5/50% |
O2 | 0-10/25% |
Optional Additional Measurements | Flow, Opacity, HCl, NH3, Cl2 and THC |
Power consumption | 700 VA for standard model. Additional 300VA required for CLD(NOx) or UV(SO2) options. |
System output Contacts | Standard: Low sample flow, thermoelectric cooler temperature, sample line temperature, analyzer malfunction, power failuer, maintenance in progress, blowback in progress, and calibration fault and range indication by channel. |
Material exposed to sampls gas | 304 and 316 stainless steel, TeflonTM, VitonTM, polypropylene, fluororubber, PVC, KynarTM,, and glass |
NEMA Rating | NEMA 12 standard, NEMA 4, or NEMA 4X optional |
Dimensions; Height: Width: Depth: |
72 in (1829 mm) 24 in (610 mm) 30 in (762 mm) |
Weight | Approx. 440 lb (200kg) |
Sample gas condition Temperature Dust NO NO2 SO2 SO3 CO CO2 H2O Others | Standard system designed for the following sample gas conditions; 250°C 0.1 g/Nm3 (0.04 grains/dscf) 1000 ppm (max. 5000ppm) 15 ppm 1000 ppm (max.5000ppm) 50 ppm 500 ppm (max. 5000ppm) 15 vol% (max. 50 vol%) 4 to 20 vol% Corrosive gases (HF, HCl, Cl2) not present; Options: NH3 scrubber, CH4 compensation |