HC-200F

Field-installation Type Fluoride Ion Concentration Meter

For the management of wastewater from semiconductor/FPD plants and glass factories.

A fluoride ion concentration meter that covers a wide range and offers a diverse lineup of cleaning devices. Combined with the fluoride ion electrode 1009 to detect free fluoride ions in the sample. Ideal for managing wastewater from semiconductor/FPD factories and glass factories.

Abteilung: Process Water
Produktionsfirma: HORIBA Advanced Techno Co., Ltd.

Supporting a wide range

With a single unit, a wide range from low to high concentrations can be covered.

Comprehensive range of cleaning devices.

A diverse lineup of cleaning devices are offered.

Product nameFluoride ion meter
ModelHC-200F
Electrode used with productFluoride ion electrode
Measurement
range
Concentration0 mg/L to 10000 mg/L (Display range: 0 mg/L to 11000 mg/L)
Available range options:
10000, 5000, 2000, 1000, 500, 200, 100, 50, 20.0, 10.0 mg/L
Temperature0℃ to 100℃ (Display range: -20℃ to 130℃)
Display
resolution
Concentration0.1 mg/L: 0.0 mg/L to 20.0 mg/L
1 mg/L: 0 mg/L to 200 mg/L
10 mg/L: 0 mg/L to 2000 mg/L
100 mg/L: 0 mg/L to 10000 mg/L
Temperature0.1℃
PerformanceConcentrationRepeatabilityWithin ±7% of the full scale (response for equivalent input)
LinearityWithin ±10% full scale (response for equivalent input)
TemperatureRepeatability±0.3℃ (response for equivalent input)
Linearity±0.3℃ (response for equivalent input)
Transmission
output
Number of output points2 (the negative terminals for transmission outputs are internally connected and at the same electric potential)
Output type4 mA to 20 mA DC, input/output isolated type
Load resistanceMax.: 900Ω
LinearityWithin ±0.08 mA (output only)
RepeatabilityWithin ±0.02 mA (output only)
Output rangeOutput 1Concentration: Selection from preset ranges or free range input within measuring range.
Output 2Temperature: Free setting within a range between -20℃ and 130℃
Occasional out for errorHold or burnout to either 3.8 mA or 21 mA
Transmission holdIn the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact outputNumber of output points3 points
Output typeNo-voltage contact output
Contact typeRelay contact, SPDT (1c)
Output capacity250 V AC 3 A, 30 V DC 3 A (resistance load)
Contact
function
R1, R2Selectable from upper limit alarm, lower limit alarm, ON/OFF control,currently holding of transmission output, and cleaning output (The contact is closed during alarm operation, opened normally and while the power is down).
FAILError alarm (Closed in the normal state, opened in the failure state or while the power is down.)
Alarm setting range
  • Setting range: within a measuring range
  • Delay time: 0 seconds to 600 seconds
Control setting range
  • Setting range: within a measuring range
  • Control width: 2 mg/L to 40% of the setting range
Cleaning outputNumber of output points1
Output typeContact output with voltage (output of connected power supply voltage)
Contact typeRelay contact; SPST (1a)
Contact capacity250 V AC 0.5 A
Contact functionActuation of solenoid valve for cleaning
SettingsCleaning period0.1 hours to 168.0 hours
Cleaning time2 seconds to 600 seconds
Hold time2 seconds to 600 seconds
Timer accuracyWithin 2 minutes per month
Description of cleaning
operation
  • Operation of internal timer
  • Operation of internal timer and external input
  • Enable the internal timer only when external input is active.
  • Choose one of the cleaning start signals (when this signal is ON for 2 seconds minimum, the internal cleaning sequence starts).
Contact inputNumber of input points1
Contact typeNo-voltage “a” contact of open collector
ConditionsON resistance: 100Ωmax.
Open voltage: 24 V DC
Short-circuit current: 12 mA DC max.
Contact functionExternal input for cleaning or transmission holding if cleaner is not attached.
Transmission
capability
Communication typeRS-485
Signal type2 wire system, isolated from the input circuit
Not isolated from transmission circuit
Temperature
compensation
Applicable temperature elementPlatinum resistor: 1 kΩ (0℃)
Positive relation resistor with temperature: 10 kΩ (25℃)
measurement range of temperature0℃ to 100℃
Temperature calibration1 point calibration comparing reference thermometer
CalibrationNumber of calibration pointsSelectable from 1, and 2 points
Kinds of standard solutionsThe first point: Calibrated by the standard solution with the density from 50% to 100% of the measuring range.
The second point: Calibrated by the standard solution with the density from 1% to 20% of the measuring range.
Additional capabilitiesAutomatic detection of calibration failure (asymmetry potential,sensitivity, or response time)
Calibration history (asymmetry potential, sensitivity, and number of days elapsed after last calibration)
Self-checkCalibration errorAsymmetry potential error, and sensitivity error
Temperature calibration error
Electrode diagnostic errorTemperature sensor short-circuit, temperature sensor disconnection,and out of the temperature measurement range
Converter errorCPU error, ADC error, and memory errors
Operating temperature range-20℃ to 55℃ (without freeze)
Operating humidity rangeRelative humidity: 5% to 90% (without condensation)
Storage temperature-25℃ to 65℃
Power supplyRated power supply voltage100 V to 240 V AC ±10% 50/60 Hz
Power consumption15 VA (max)
OthersWith power switch for maintenance use
Compatible
standards
CE markingEMC  :EN61326-1
    Class A, Indrial electromagnetic environmentust
Safety :EN61010-1
RoHS  :EN50581
    9. Industrial monitoring and control instruments
FCC rulesPart15 Class A
StructureInstallationOutdoor installation type
Installation methodMounted on 50 A pole or wall
Protection codeIP65
Case materialAluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittingsSUS304
Material of hoodSUS 304 stainless steel
(coated with epoxy-denatured melamine resin)
Material of windowPolycarbonate
Display elementReflective monochrome LCD
External dimensions180 (W) × 155 (H) × 115 (D) mm (excluding mounting brackets)
MassMain body: Approx. 3.5 kg
Cover and mounting brackets: Approx. 1 kg

*:  When the sensor cable, the transmission cable, or the contact input cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.

Note

An arrester (spark over voltage: 400 V) is implemented for transmission output, contact input, and communication. However, use a most suitable surge absorption element on the connection lines in accordance with the ambient environment, the situation of equipment installed, and the externally connected equipment.

Informationsanfrage

Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten.

* Diese Felder sind Pflichtfelder.

Related products

Aqualog Datastream
Aqualog Datastream

For Instant Water Quality Reports

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HC-200NH
HC-200NH

Field-installation type ammonia nitrogen meter

HC-300F
HC-300F

Field-installation Type Fluoride Ion Concentration Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-200FL
HD-200FL

Field-installation type optical dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

514-05
514-05

0.5% NaCl Standard Solution

514-22
514-22

1.41 mS/cm Conductivity Standard Solution

514-23
514-23

12.9 mS/cm Conductivity Standard Solution

514-50
514-50

5.0% NaCl Standard Solution

Water & Liquid Corporate