HE-200R

Field-installation type electric resistivity meter (resistivity meter)

For measuring the electric resistivity of UPW (ultra-pure water).

Combined with the electric resistivity sensor (ERF series), it measures the electric resistivity and temperature of aqueous solutions. Suitable for measuring electric resistivity of UPW.

RESIST

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Enables measurements with minimal error

Measurements are affected less by ambient temperature and sample temperature, enabling accurate measurements with less error.

We provide equipment and sensor calibration services

Temperature sensor offset calibration is offered as well as converter and sensor combination calibration services. *Option

Highly responsive temperature sensor

Helps to minimize fluctuations in measurement values due to delayed temperature compensation in the event of sudden changes in water temperature.

Product name Resistivity meter
Model HE-200R
Combined
sensor
2-electrode method resistivity sensor (ERF-001 Series) of cell constant 0.01/cm
Measuring range Resistivity MΩ•cm 0.000 to 2.000 0.00 to 20.00 (*Note 1)
kΩ•cm 0.00 to 20.00 0.0 to 200.0 (*Note 1)
Temperature 0℃ to 100℃ (Display range: −10℃ to 110℃)
Display
resolution
Resistivity As shown in the measuring table.
Temperature 0.01℃
Performance Resistivity Repeatability Within ±0.1% of the full scale (response for equivalent input)
Linearity Within ±0.5% of the full scale (response for equivalent input)
Temperature Repeatability ±0.1℃ (response for equivalent input)
Linearity ±0.5℃ (response for equivalent input)
Transmission
output
Number of output 2 (The negative terminals for transmission outputs are internally connected at the same electric potential)
Output type 4 mA to 20 mA DC: input/output isolated type
Load resistance Maximum: 900Ω
Linearity Within ±0.08 mA (output only)
Repeatability Within ±0.02 mA (output only)
Output range Output 1 Resistivity: Free setting within a measuring range.
Output 2 Temperature: Free setting within a range between −20 and 130℃
Occasional out for error Hold or burnout to either 3.8 mA or 21 mA
Transmission hold In the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact output Number of output 3
Output type No-voltage contact output
Contact type Relay contact; SPDT (1c)
Contact capacity 250 V AC, 3 A; 30 V DC, 3 A (resistance load)
Contact
function
R1, R2 Selectable from upper limit alarm, lower limit alarm, and currently holding of transmission output.
(The contact is closed during alarm operation, opened normally and while the power is down.)
FAIL Error alarm
(Closed in the normal state, opened in the failure state or while the power is down.)
Alarm setting range
  • Setting range: within a measuring range
  • Delay time: 0 to 600 seconds
Contact input Number of input points 1
Contact type No-voltage "a" contact for open collector
Conditions ON resistance: 100 Ω max.
Open voltage: 24 V DC
Short-circuit current: 12 mA DC max.
Contact function External input for transmission holding.
Transmission
capability
Method RS-485
Signal type 2 wire system, isolated from the input circuit
Not isolated from transmission circuit
Temperature
compensation
Applicable temperature
element
Platinum resistor: 1 kΩ (0℃)
Compensation method
  • Temperature characteristic of NaCl (reference temperature: 5℃ to 95℃)
  • Arbitrary temperature coefficient input (reference temperature: 5℃ to 95℃; temperature coefficient: +/−3%/℃)
  • No temperature compensation
    One of the three ways of compensation is selectable.
    (In the de-ionized water area, the temperature compensation for pure water is automatically performed in both NaCl and arbitrary temperature coefficient compensation settings.)
Temperature compensation
range
0℃ to 100℃ (However, the compensation calculation is extended lower than 0℃ or higher than 100℃.)
Calibration Resistivity Based on parameter input of coefficient for the sensor cell constant.
Temperature Comparison to the accurate thermometer
Both deviation and coefficient of RTD are taken into account for calibration.
Other function UPW standard resistivity input Select one from the next.
182.3 kΩ•m (standard), 181.8 kΩ•m, 182.4 kΩ•m,
18.23 MΩ•cm (standard), 18.18 MΩ•cm, or 18.24 MΩ•cm
Clipping function If the measured value exceeds the user setting value for clipping, the measured data will be held at the clipping value.
Self-check Sensor diagnostic error Temperature sensor short-circuit, temperature sensor disconnection, and out of the temperature measurement range
Converter error CPU, ADC, and memory errors
Operating
temperature
range
−20℃ to 55℃ (without freeze)
Operating
humidity range
Relative humidity: 5% to 90% (without condensation)
Storage
temperature
−25℃ to 65℃
Power supply Rated power supply voltage 100 V to 240 V AC ±10% 50/60 Hz
Power consumption 15 VA (max)
Other With power switch for maintenance use
Compatible
standards
CE marking EMC    :EN61326-1
     Class A, Industrial electromagnetic environment
Safety   :EN61010-1
RoHS    :EN50581
      9. Industrial monitoring and control instruments
FCC rules Part15 Class A
Structure Installation Outdoor installation type
Installation method Mount on 50 A pole or wall
Protection code IP65
Case material Aluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittings SUS304
Material of hood SUS304 stainless steel (coated with epoxy denatured melamine resin)
Material of window Polycarbonate
Display element Reflective monochrome LCD
External
dimensions
180 (W) mm × 155 (H) mm × 115 (D) mm (excluding cover and mounting brackets)
Mass Main body: Approx. 3.5 kg; cover and mounting brackets: Approx. 1 kg

Note

  • Note 1  : Without temperature compensation, 0.0-100.0 MΩ•cm(0-1000 kΩ•m) can be displayed.
  • Note 2  : When the sensor cable, the transmission cable, or the contact input cable is extended by 30 m or more, the surge test under the EMC Directive for CE marking is not applied.
  • Note 3  : An arrester (spark over voltage: 400 V) is implemented for transmission output, contact input, and communication. However, use a most suitable surge absorption element on the connection lines in accordance with the ambient environment, the situation of equipment installed, and the externally connected equipment.