Measurement range volume flow | 0.2 - 220 l/h |
Measurement range density | 0.5 - 2g/cm³ |
Fuel Pressure of system | 2 - 2.5 bar |
Supply voltage | 230 V |
Power frequency | 50/60 Hz |
Nominal current | 2 A |
Size | 675mmx1120mmx540mm |
Test Unit for Fuel Measurement Systems
FACT 220 is a test device for automatic calibration verification of the sensors used in the fuel flow measurement systems of the FQ Series. Consisting of a density sensor and a flow sensor, the FACT 220 is suitable for checking the entire measuring range from 0.2 to 220l/h. The test device can be operated either at the inlet circuit of the FQ systems or like a test object in the outlet circuit. Flow deviations are evaluated with a status display. A test report is automatically generated at the end of the test procedure.
Connected via Ethernet, all functions such as manual and automatic testing and rinsing can be performed directly via the touch panel. The test unit has been designed for commercial fuels and ethanol up to 100%, kerosene and biodiesel. An additional tank unit allows the subsequent flushing with a preservative medium.
Do you have any questions or requests? Use this form to contact our specialists.