OPSA-150

μœ κΈ°μ˜€μ—Όλ¬Όμ§ˆ λͺ¨λ‹ˆν„°

OPSA-150은 HORIBA의 μ „λ¬Έ κΈ°μˆ μ„ μ ‘λͺ©ν•œ λ…μžμ μΈ λ‘œν„°λ¦¬ μ…€ 길이 λ³€μ‘°λ₯Ό μ‚¬μš©ν•œ μœ κΈ°μ˜€μ—Όλ¬Όμ§ˆ λͺ¨λ‹ˆν„°μž…λ‹ˆλ‹€.
ν•΄λ‹Ή μž₯λΉ„λŠ” 배수 μ‹œμŠ€ν…œμ˜ 유기 μ˜€μ—Ό 물질 λͺ¨λ‹ˆν„°λ§, κΈ‰μˆ˜ 취수ꡬ의 유기 물질 μˆ˜μ€€μ„ μΈ‘μ •ν•˜κΈ° μœ„ν•œ 수질 λͺ¨λ‹ˆν„°λ§ 및 ν”„λ‘œμ„ΈμŠ€ 라인(νŽ˜λ†€ 뢄석기)의 유기 μ˜€μ—Ό 물질 λͺ¨λ‹ˆν„°λ§μ΄ κ°€λŠ₯ν•©λ‹ˆλ‹€.

*μ˜΅μ…˜ : 폴 마운트, 아웃도어 컀버, 뢄석 νŒ¨λ„

Division: Water Pollution
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

λ‘œν„°λ¦¬ μ…€ 길이 λ³€μ‘° 기반의 κ³ μ„±λŠ₯ μ„Όμ„œ

(JAPAN Patent No. 4627022, KOREA Patent No. 10-0840034, CHINA Patent No. ZL200610110930.8)

  • μ…€μ˜ νšŒμ „μœΌλ‘œ μΈν•œ 연속 μ„Έμ •κ³Ό 제둜 점 체크λ₯Ό ν•˜κΈ° λ•Œλ¬Έμ— 제둜 ꡐ정 ν•„μš” μ—†μŒ

  • μ…€ 길이의 변화에 μ˜ν•΄, 0~0.1 Abs의 저농도 λΆ€ν„° 0 ~ 5.0 Abs의 κ³ λ†λ„κΉŒμ§€μ˜ 폭넓은 μΈ‘μ • λ²”μœ„ 


 

κ°„νŽΈν•œ 컨트둀 νŒ¨λ„

OPSA-150은 μ§κ΄€μ μœΌλ‘œ μ„€κ³„λœ ν„°μΉ˜ νŒ¨λ„μ„ 톡해 μ œμ–΄λ¨. λŒ€ν™”ν˜• μ„€μ • 화면을 μ œκ³΅ν•˜μ—¬ μ‘°μž‘ μ‹œ λ°œμƒν•  수 μžˆλŠ” μ‚¬μš©μžμ˜ ν˜Όμ„ μ„ 방지함. λ˜ν•œ, ν™˜μ‚° COD 및 탁도(TURB) ν‘œμ‹œ κΈ°λŠ₯을 톡해 츑정값을 ν˜„μž₯μ—μ„œ μ¦‰μ‹œ 확인할 수 있음.

μ΅œλŒ€ 1λ…„μ˜ μžλ™ 데이터 기둝

μ‹œκ°„λ‹Ή 1 개 데이터 μΈ‘μ • κΈ°μ€€, μ΅œλŒ€ 1 λ…„ λΆ„λŸ‰μ˜ 데이터λ₯Ό λ‚΄λΆ€ λ©”λͺ¨λ¦¬μ— μ €μž₯ κ°€λŠ₯함. μ»΄νŒ©νŠΈν”Œλž˜μ‹œ* μΉ΄λ“œλ₯Ό μ‚¬μš©ν•˜μ—¬ PC둜의 데이터 전솑이 μš©μ΄ν•¨.

* μ»΄νŒ©νŠΈν”Œλž˜μ‹œ(CompactFlash)λŠ” λ―Έκ΅­ 및 기타 κ΅­κ°€μ—μ„œ SanDisk Corporation의 등둝 μƒν‘œ λ˜λŠ” μƒν‘œμž„.

 

HORIBA λ…μž μ œμ–΄ 와이퍼 μ‹œμŠ€ν…œ

와이퍼가 셀을 μ§€μ†μ μœΌλ‘œ μ„Έμ •ν•˜μ—¬ μΈ‘μ • κ΄‘λ‘œ(Light path)μƒμ˜ κ°„μ„­ μš”μΈμ„ μ œκ±°ν•¨. 이에 따라 μ…€μ˜ μ˜€μ—ΌμœΌλ‘œ μΈν•œ μΈ‘μ • 였λ₯˜λ‚˜ μ„Έμ • μ „ν›„μ˜ κ²°κ³Ό νŽΈμ°¨κ°€ λ°œμƒν•˜μ§€ μ•ŠμŒ.

 

μƒ˜ν”Œ μœ μž… 이상 접점 μž…λ ₯

이전 λͺ¨λΈμΈ OPSA-120μ—μ„œ μ˜΅μ…˜μœΌλ‘œ 제곡되던 μƒ˜ν”Œ 였λ₯˜ μ•ŒλžŒ κΈ°λŠ₯을 ν‘œμ€€ μ‚¬μ–‘μœΌλ‘œ κΈ°λ³Έ νƒ‘μž¬

 

뢄석 감도 10 λ°° ν–₯상

  • 뢄석 μ •λ°€λ„μ˜ μ΅œμ†Œ λ‹¨μœ„λ₯Ό 0.0001 AbsκΉŒμ§€ κ΅¬ν˜„, κΈ°μ‘΄ λͺ¨λΈ(OPSA-120) λŒ€λΉ„ 감도λ₯Ό 10 λ°° ν–₯μƒμ‹œν‚΄ 
  • 0 ~ 0.1 Abs μˆ˜μ€€μ˜ μ΄ˆμ €λ†λ„ μ˜μ—­μ—μ„œλ„ μ •λ°€ μΈ‘μ • κ°€λŠ₯
Product nameOrganic Pollutant Monitor (UV meter)
ModelOPSA-150
Measurement itemUV absorbance, VIS absorbance, COD conversion concentration, TURB (turbidity) conversion concentration
Measurement principleDual optical path, Dual wavelength, rotary cell length modulation method
Measurement wavelengthUltraviolet: 253.7 nm, Visible light: 546.1 nm
Structure of analyzer unitCirculation type
Measurement range
(converted by cell 10mm)
UV absorbance/VIS absorbance
Full scale: 0.1 Abs to 5.0 Abs (setting by 0.1 Abs is possible)
Minimum scale0.0001 Abs (changeable to 0.001 Abs)
RepeatabilityWithin Β±2.0% of full scale
(Within Β±5.0% of full scale for 2.6 Abs to 5.0 Abs)
LinearityWithin Β±2.0% of full scale
(Within Β±5.0% of full scale for 2.6 Abs to 5.0 Abs)
StabilityWithin Β±2.0%/24 h of full scale
(Within Β±4.0%/24 h of full scale for 2.6 Abs to 5.0 Abs)
Response timeT90, within 1 minute (flow rate of approximately 5 L/min)
Cleaning method
(cleaning cycle)
Automatic cleaning by wiper (automatic continuous cleaning)
Display methodLCD display:
320 Γ— 240 monochrome graphics LCD data display with dot backlighting (a touch-panel)
Display content:
UV absorbance, VIS absorbance, UV-VIS absorbance, COD conversion concentration, TURB (turbidity) conversion concentration
Calibration methodSolution calibration using zero solution and span solution (calibration solution in the ampoule)
(one-touch calibration is possible)
Sample water conditionTemperature: 2Β°C to 40Β°C (should not be frozen)
Flow rate of sample water: Min. 2 L/min, Max. 20 L/min
* Keep the unit warm (or preserve the heat) to ensure protection against frozen sample water in the cold weather.
Ambient temperature and
humidity
Ambient temperature: 0Β°C to 40Β°C, Ambient humidity: 85% or below
Analog outputPoint: 3
Type: arbitrary 3 items from UV absorbance, VIS absorbance, UV-VIS
absorbance, COD conversion concentration, and TURB (turbidity) conversion
concentration (selectable)
Specification: 4 mA to 20 mA DC or 0 mA to 16 mA DC, insulated output
(however, non-insulated among each channel)
Maximum load resistance: 600 Ξ©
Contact outputPoint: 6
Type: arbitrary 4 items from POWER OFF, MAINTENANCE (standard, fixed allocation)
BATCH ALARM, COD MAX ALARM, TURB MAX ALARM (standard), LIGHT SOURCE MALFUNCTION, NO SAMPLE, CLEANING MOTOR ERROR,
ANALYZER ERROR (selectable)
Content: POWER OFF: when the power OFF occurred.
BATCH ALARM: CLEANING MOTOR ERROR, LIGHT SOURCE
MALFUNCTION, ANALYZER ERROR
MAINTENANCE: at in-maintenance mode and calibration mode, and when maintenance switch is ON.
Specification: contact output without voltage, a contact
Contact rating: 125 V AC/0.3 A, 30 V DC/1 A
(however, for load resistance) each output COM-independent
Contact inputPoint: 2
Type: Float switch input, time adjustment input
Specification: contact input without voltage (open collector can be connected), insulated input
ON resistance: Max. 100 Ξ©, Open voltage: 5.5 V DC, Short circuit current:
Max. 10 mA
CommunicationInterface: RS-232C compliant
Communication speed: 19200 bps
Data memoryMemorize the data of measurement value of the measurement item in the main body.
Memorized data can be transferred to the CF card.
Memory interval: 1 minute or 1 hour
Memory time: on the hour every hour
Data memory time: interval of 1 minute: approximately 10 days
interval of 1 hour: approximately 1 year
* The latest data is memorized.
Light source/detectorLight source: low pressure mercury-vapor lamp, detector: silicon photo diode
Piping sockets
  • Sample inlet Rp-1/2 female
  • Bypass outlet Rc-1/2 female
  • Overflow outlet (1) Elbow fitting, 13A (nominal)
  • Overflow outlet (2) Elbow fitting, 20A (nominal)
  • Drain outlet Rc-1/2 female
  • Discharge Tube coupling, 50A (nominal)
StructureWeather-proofed for outdoor installation (equivalent to IP54)
Main material of each unitSUS, PVC, PP, CR, SiO2
Power100 V to 230 V AC Β±10%, 50/60 Hz
Power consumption100 V to 120 V AC, Max. 45 VA
200 V to 230 V AC, Max. 60 VA
MassControl unit: approximately 5.0 kg
Analyzer unit: approximately 5.6 kg
DimensionControl unit: 240 (W) Γ— 104 (D) Γ— 320 (H) mm
Analyzer unit: 200 (W) Γ— 180 (D) Γ— 403 (H) mm
(Protruding portion are not included.)
Painting colorControl unit: Munsel 5PB 8/1
Conditions for installation
  • Flat and stable places free from strong vibration or shock
  • Places free from dirt or dust, or where no corrosive gases will be generated.
  • At the atmospheric pressure
  • Places not subject to direct sunlight
  • Places well-ventilated
  • Altitude of 2000 m or below

μ œν’ˆ 문의

HORIBAμ œν’ˆμ˜ μžμ„Έν•œ 정보λ₯Ό μ›ν•˜μ‹œλ©΄, μ•„λž˜μ˜ 양식에 λ‚΄μš©μ„ μž…λ ₯을 λΆ€νƒλ“œλ¦½λ‹ˆλ‹€.

* λŠ” ν•„μˆ˜μž…λ ₯ν•­λͺ©μž…λ‹ˆλ‹€.

Related products

CODA-500
CODA-500

μžλ™ COD μΈ‘μ •κΈ°

CS-620F
CS-620F

κ΄‘μ„¬μœ ν˜• 고온 인산 농도 λͺ¨λ‹ˆν„°

CS-900
CS-900

비접촉 ν™”ν•™λ¬Όμ§ˆ 농도 λͺ¨λ‹ˆν„°

HD-960L
HD-960L

저농도 용쑴 μ‚°μ†Œ λͺ¨λ‹ˆν„°

HD-960LR
HD-960LR

용쑴 μ‚°μ†Œ 농도 λͺ¨λ‹ˆν„°

HE-480C-GC
HE-480C-GC

μΉ΄λ³Έ μ„Όμ„œ 전도도계 (μ €λ†λ„ν˜•)

HE-960CA
HE-960CA

ꡬ연산 λͺ¨λ‹ˆν„°

HE-960H-KOH
HE-960H-KOH

KOH λͺ¨λ‹ˆν„°

HE-960H-TM-S
HE-960H-TM-S

κ³ μ •λ°€ TMAH 농도 λͺ¨λ‹ˆν„°

HE-960HC
HE-960HC

μΉ΄λ³Έ μ„Όμ„œ 전도도계 (κ³ λ†λ„ν˜•)

HE-960LC
HE-960LC

μΉ΄λ³Έ μ„Όμ„œ 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 μΉ΄λ³Έ μ„Όμ„œ 전도도계

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 μ €ν•­λ₯ κ³„

HF-960EM
HF-960EM

인라인 μ„Όμ„œ 및 μžλ™ λ²”μœ„ μ „ν™˜ 농도 λͺ¨λ‹ˆν„°

HF-SP-CU
HF-SP-CU

2-채널 κ³ μ •λ°€ HF 농도 λͺ¨λ‹ˆν„°

HT-110
HT-110

μ΄μœ κΈ°νƒ„μ†Œ λͺ¨λ‹ˆν„°

HU-200SS
HU-200SS

ν˜„μž₯μ„€μΉ˜ν˜• MLSS Meter (4-Wire Transmission)

HU-200TB-H
HU-200TB-H

ν˜„μž₯μ„€μΉ˜ν˜• 탁도계 (4-Wire Transmission, High-sensitivity)

HU-200TB-IM
HU-200TB-IM

κ³΅μ •μš© μ‚½μž…ν˜• SS/탁도 μΈ‘μ •κΈ°

HU-200TB-W
HU-200TB-W

ν˜„μž₯ μ„€μΉ˜ν˜• 탁도계 (4-Wire Transmission, For Wide Range)

HZ-960
HZ-960

μš©ν•΄ 였쑴 λͺ¨λ‹ˆν„°

HZ-960HPO-M
HZ-960HPO-M

H2O2 λͺ¨λ‹ˆν„°

OPSA-150
OPSA-150

μœ κΈ°μ˜€μ—Όλ¬Όμ§ˆ λͺ¨λ‹ˆν„°

SLIA-300
SLIA-300

고감도 싀리카 뢄석기

SLIA-5000
SLIA-5000

싀리카 μΈ‘μ •κΈ°

TPNA-500
TPNA-500

μžλ™ μ΄μ§ˆμ†Œ/총인 μΈ‘μ •κΈ°

TW-100
TW-100

μžλ™ 수질 μΈ‘μ •μž₯치

TW-150
TW-150

Online Water Quality Monitor (곡정 수질 μΈ‘μ • μ‹œμŠ€ν…œ)

U-50 Series
U-50 Series

λ‹€ν•­λͺ© 수질 μΈ‘μ •κΈ°

Ultima Expert LT
Ultima Expert LT

Affordable high performance ICP-OES

UP-100
UP-100

마이크둜 λ³Όλ₯¨ pH λͺ¨λ‹ˆν„°

CS-620F
CS-620F

κ΄‘μ„¬μœ ν˜• 고온 인산 농도 λͺ¨λ‹ˆν„°

CS-900
CS-900

비접촉 ν™”ν•™λ¬Όμ§ˆ 농도 λͺ¨λ‹ˆν„°

HU-200SS
HU-200SS

ν˜„μž₯μ„€μΉ˜ν˜• MLSS Meter (4-Wire Transmission)

HU-200TB-H
HU-200TB-H

ν˜„μž₯μ„€μΉ˜ν˜• 탁도계 (4-Wire Transmission, High-sensitivity)

HU-200TB-IM
HU-200TB-IM

κ³΅μ •μš© μ‚½μž…ν˜• SS/탁도 μΈ‘μ •κΈ°

HU-200TB-W
HU-200TB-W

ν˜„μž₯ μ„€μΉ˜ν˜• 탁도계 (4-Wire Transmission, For Wide Range)

HZ-960
HZ-960

μš©ν•΄ 였쑴 λͺ¨λ‹ˆν„°

HZ-960HPO-M
HZ-960HPO-M

H2O2 λͺ¨λ‹ˆν„°

OPSA-150
OPSA-150

μœ κΈ°μ˜€μ—Όλ¬Όμ§ˆ λͺ¨λ‹ˆν„°

TPNA-500
TPNA-500

μžλ™ μ΄μ§ˆμ†Œ/총인 μΈ‘μ •κΈ°

U-50 Series
U-50 Series

λ‹€ν•­λͺ© 수질 μΈ‘μ •κΈ°

Corporate